CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

HL19B2421

MOMENTUM · source records, page 3

61 published source records · source checked Sep 21, 2026

SEER2 range16–18BTU/Wh
HSPF2 range7.8BTU/Wh
Cooling capacity21,200–24,000BTU/h

Each efficiency range summarizes published EPA records for HL19B2421. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 61 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–1861 / 61
EER2 · BTU/Wh11.7–1461 / 61
HSPF2 · BTU/Wh7.861 / 61
Cooling capacity · BTU/h21,200–24,00061 / 61
Heating capacity at 47°F / 8.3°C · BTU/h22,400–23,80061 / 61
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,20061 / 61
Heating capacity at 5°F / −15°C · BTU/h10,900–12,20061 / 61
COP at 5°F / −15°C1.8–2.0661 / 61
Equipment / loop typeHP - Split System61 / 61
Refrigerant / source-reported GWPR-410A (GWP:2088)61 / 61
Compressor stagingTwo-stage61 / 61
Connected capabilityNo61 / 61

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAFA30DBAN1+ furnace: Z8ES040A12LMPS1AHRI reference: 21248459617.007.80110001.80EPA 3990577
XAHB36DBAN1+ furnace: Z8ES080B12LMPS1AHRI reference: 21248880017.007.80109001.80EPA 3991098
XAHB36DBAN1+ furnace: TP9C080B12MP13AHRI reference: 20936999016.007.80110002.00EPA 2475943
XAHB36DBAN1+ furnace: TM9V080B12MP12AHRI reference: 20936998616.007.80110002.00EPA 2476703
XAHB36DBAN1+ furnace: TM9V060B12MP12AHRI reference: 20937000616.007.80112001.98EPA 2476708
XAHB36DBAN1+ furnace: TM9E026A08MP12AHRI reference: 20937002416.007.80111001.96EPA 2476716
XAHB36DBAN1+ furnace: TM8Y080B12MP11AHRI reference: 20937002816.007.80109002.02EPA 2476719
XAHB36DBAN1+ furnace: TL9E060B12UH11AHRI reference: 20937006616.007.80112002.00EPA 2476725
XAHB36DBAN1+ furnace: TP9C060B12MP13AHRI reference: 20937001016.007.80112001.98EPA 2476728
XAHB36DBAN1+ furnace: TM8V080B12MP12AHRI reference: 20937004516.007.80112001.98EPA 2476735
XAHB36DBAN1+ furnace: TM9E080B12MP12AHRI reference: 21029696716.007.80110001.98EPA 3984169
XAHB36DBAN1+ furnace: TM9Y060B12MP11AHRI reference: 21029629516.007.80110002.00EPA 3984343
XAHB36DBAN1+ furnace: TM9Y080B12MP11AHRI reference: 21029631916.007.80110002.00EPA 3984348
XAHB36DBAN1+ furnace: TM9E060B12MP12AHRI reference: 21029632716.007.80114001.98EPA 3984352
XAHB36DBAN1+ furnace: Z9ES060B12SMPS1AHRI reference: 21176874016.007.80120002.06EPA 3990166
XAFB36DBAN1+ furnace: Z9ES060B12SMPS1AHRI reference: 21176873516.007.80116001.80EPA 3990167
XAFA30DBAN1+ furnace: Z9ES026A08SMPS1AHRI reference: 21176871616.007.80112001.98EPA 3990168
XAHB36DBAN1+ furnace: Z9ET060B12SMPS1AHRI reference: 21176869016.007.80118002.00EPA 3990286
XAFA30DBAN1+ furnace: Z9ET040A10SMPS1AHRI reference: 21176869816.007.80122002.00EPA 3990290
XAFA30DBAN1+ furnace: Z9ES060A10SMPS1AHRI reference: 21176872916.007.80115002.02EPA 3990307