CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

HH860E2S12

LX SERIES · source records, page 6

372 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range8.1–8.5BTU/Wh
Cooling capacity43,500–54,000BTU/h

Each efficiency range summarizes published EPA records for HH860E2S12. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 372 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18372 / 372
EER2 · BTU/Wh11–12372 / 372
HSPF2 · BTU/Wh8.1–8.5372 / 372
Cooling capacity · BTU/h43,500–54,000372 / 372
Heating capacity at 47°F / 8.3°C · BTU/h44,000–53,500372 / 372
Heating capacity at 17°F / −8.3°C · BTU/h40,000–45,500372 / 372
Heating capacity at 5°F / −15°C · BTU/h33,600–40,000372 / 372
COP at 5°F / −15°C2–2.32372 / 372
Equipment / loop typeHP - Split System372 / 372
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)372 / 372
Compressor stagingTwo-stage372 / 372
Connected capabilityNo372 / 372

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU60C5XGS2+TXV+ furnace: TPLC100C20MP13AHRI reference: 21868984017.508.10340002.20EPA 4683134 →
CTM60C5CGS2+ furnace: TPLC120C20MP13AHRI reference: 21868983917.508.10338002.20EPA 4683135 →
CTM60C5CGS2+ furnace: TPLC080C16MP13AHRI reference: 21868983417.508.10338002.20EPA 4683138 →
CTM60D5CGS2+ furnace: TM9V120D20MP12AHRI reference: 21868982817.508.10338002.20EPA 4683141 →
CTF60D5CGS2+ furnace: TM9V120D20MP12AHRI reference: 21868982617.508.10338002.20EPA 4683143 →
CTM60C5CGS2+ furnace: TM9V100C20MP12AHRI reference: 21868982217.508.10342002.22EPA 4683145 →
CTF60C5CGS2+ furnace: TM9V100C20MP12AHRI reference: 21868982117.508.10344002.20EPA 4683146 →
CTU60C5XGS2+TXV+ furnace: TM9V100C20MP12AHRI reference: 21868982017.508.10344002.20EPA 4683147 →
CTM60C5CGS2+ furnace: TM9V100C16MP12AHRI reference: 21868981517.508.10338002.20EPA 4683148 →
CTM60C5CGS2+ furnace: TM8V120C20MP12AHRI reference: 21868981217.508.10338002.20EPA 4683151 →
CTM60C5CGS2+ furnace: TM8V100C16MP12AHRI reference: 21868980917.508.10338002.20EPA 4683152 →
CTM60C5CGS2+ furnace: TM8V100C20MP12AHRI reference: 21868980417.508.10338002.20EPA 4683155 →
CTU60C5XGS2+TXV+ furnace: TM8V120C20MP12AHRI reference: 21868980317.508.10340002.20EPA 4683156 →
CTF60C5CGS2+ furnace: TM8V120C20MP12AHRI reference: 21868980217.508.10340002.20EPA 4683157 →
CTU60C5XGS2+TXV+ furnace: TM8V100C20MP12AHRI reference: 21868980117.508.10340002.20EPA 4683158 →
CTF60C5CGS2+ furnace: TM8V100C20MP12AHRI reference: 21868980017.508.10340002.20EPA 4683159 →
CTM60C5CGS2+ furnace: TM8V080C16MP12AHRI reference: 21868979717.508.10338002.20EPA 4683162 →
CTM60C5CGS2+ furnace: TMLV120C20MP12AHRI reference: 21868979417.508.10338002.20EPA 4683163 →
CTF60C5CGS2+ furnace: TMLV120C20MP12AHRI reference: 21868979317.508.10340002.20EPA 4683164 →
CTU60C5XGS2+TXV+ furnace: TMLV120C20MP12AHRI reference: 21868979217.508.10340002.20EPA 4683165 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →