CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

HH860E2S12

LX SERIES · source records, page 14

372 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range8.1–8.5BTU/Wh
Cooling capacity43,500–54,000BTU/h

Each efficiency range summarizes published EPA records for HH860E2S12. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 372 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18372 / 372
EER2 · BTU/Wh11–12372 / 372
HSPF2 · BTU/Wh8.1–8.5372 / 372
Cooling capacity · BTU/h43,500–54,000372 / 372
Heating capacity at 47°F / 8.3°C · BTU/h44,000–53,500372 / 372
Heating capacity at 17°F / −8.3°C · BTU/h40,000–45,500372 / 372
Heating capacity at 5°F / −15°C · BTU/h33,600–40,000372 / 372
COP at 5°F / −15°C2–2.32372 / 372
Equipment / loop typeHP - Split System372 / 372
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)372 / 372
Compressor stagingTwo-stage372 / 372
Connected capabilityNo372 / 372

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF60C5CGS2+ furnace: TM8V080C16MP12AHRI reference: 21868979817.008.10340002.20EPA 4683161 →
CTF60C5CGS2+ furnace: TMLV100C16MP12AHRI reference: 21868979017.008.10340002.20EPA 4683167 →
CTU60C5XGS2+TXV+ furnace: TMLV100C16MP12AHRI reference: 21868978917.008.10340002.20EPA 4683168 →
CTM60C5CGS2+ furnace: TL9E080C16UH11AHRI reference: 21868978517.008.10346002.20EPA 4683172 →
CTU60C5XGS2+TXV+ furnace: TL9E100C20UH11AHRI reference: 21868978217.008.10342002.22EPA 4683173 →
CTF60C5CGS2+ furnace: TL9E100C20UH11AHRI reference: 21868978117.008.10342002.22EPA 4683174 →
CTM60C5CGS2+ furnace: TL9E100C20UH11AHRI reference: 21868978017.008.10350002.24EPA 4683175 →
CTF60C5CGS2+ furnace: TL8E080C16UH11AHRI reference: 21868977917.008.10342002.20EPA 4683176 →
CTU60C5XGS2+TXV+ furnace: TL8E080C16UH11AHRI reference: 21868977817.008.10342002.20EPA 4683177 →
CTM60C5CGS2+ furnace: TL8E080C16UH11AHRI reference: 21868977717.008.10342002.20EPA 4683178 →
CTU60C5XGS2+TXV+ furnace: TL8E100C20UH11AHRI reference: 21868977317.008.10350002.26EPA 4683180 →
CTF60C5CGS2+ furnace: TL8E100C20UH11AHRI reference: 21868977217.008.10350002.26EPA 4683181 →
CTF60C5CGS2+ furnace: TL9E080C16UH11AHRI reference: 21868977117.008.10344002.20EPA 4683182 →
CTU60C5XGS2+TXV+ furnace: TL9E080C16UH11AHRI reference: 21868977017.008.10344002.20EPA 4683183 →
CTU60C5XGS1+TXV+ furnace: Z9ET080C16SMPS1AHRI reference: 21870038117.008.10346002.20EPA 4684933 →
CTF60C5CGS1+ furnace: Z9ET080C16SMPS1AHRI reference: 21870037717.008.10346002.20EPA 4684937 →
CTM60C5CGS1+ furnace: Z9ES100C20SMPS1AHRI reference: 21870034917.008.10350002.24EPA 4684965 →
CTM60C5CGS1+ furnace: Z9ES080C20SMPS1AHRI reference: 21870033717.008.10342002.20EPA 4684977 →
CTU60C5XGS1+TXV+ furnace: Z9ET100C20SMPS1AHRI reference: 21870031717.008.10350002.24EPA 4684997 →
CTF60C5CGS1+ furnace: Z9ET100C20SMPS1AHRI reference: 21870031317.008.10350002.24EPA 4685001 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →