CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

HH860E2S12

LX SERIES · source records, page 12

372 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range8.1–8.5BTU/Wh
Cooling capacity43,500–54,000BTU/h

Each efficiency range summarizes published EPA records for HH860E2S12. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 372 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18372 / 372
EER2 · BTU/Wh11–12372 / 372
HSPF2 · BTU/Wh8.1–8.5372 / 372
Cooling capacity · BTU/h43,500–54,000372 / 372
Heating capacity at 47°F / 8.3°C · BTU/h44,000–53,500372 / 372
Heating capacity at 17°F / −8.3°C · BTU/h40,000–45,500372 / 372
Heating capacity at 5°F / −15°C · BTU/h33,600–40,000372 / 372
COP at 5°F / −15°C2–2.32372 / 372
Equipment / loop typeHP - Split System372 / 372
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)372 / 372
Compressor stagingTwo-stage372 / 372
Connected capabilityNo372 / 372

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU60C5XGS2+TXV+ furnace: Z9ET100C20SMPS1AHRI reference: 21864243817.008.10350002.24EPA 4665267 →
CTF60C5CGS2+ furnace: Z9ET100C20SMPS1AHRI reference: 21864243317.008.10350002.24EPA 4665272 →
CTU60C5XGS2+TXV+ furnace: Z9ES100C20SMPS1AHRI reference: 21864242717.008.10350002.24EPA 4665278 →
CTF60C5CGS2+ furnace: Z9ES100C20SMPS1AHRI reference: 21864242117.008.10350002.24EPA 4665284 →
CTU60C5XGS2+TXV+ furnace: Z8ET120C20LMPS1AHRI reference: 21864234917.008.10344002.24EPA 4665356 →
CTF60C5CGS2+ furnace: Z8ET120C20LMPS1AHRI reference: 21864234217.008.10344002.24EPA 4665363 →
CTM60D5CGS2+ furnace: Z9ET120D20SMPS1AHRI reference: 21864225717.008.10344002.24EPA 4665448 →
CTU60C5XGS2+TXV+ furnace: Z8ES120C20LMPS1AHRI reference: 21864220317.008.10348002.24EPA 4665502 →
CTU60C5XGS2+TXV+ furnace: Z8ES120C20SMPS1AHRI reference: 21864219717.008.10348002.24EPA 4665508 →
CTF60C5CGS2+ furnace: Z8ES120C20LMPS1AHRI reference: 21864219117.008.10348002.24EPA 4665514 →
CTF60C5CGS2+ furnace: Z8ES120C20SMPS1AHRI reference: 21864218517.008.10348002.24EPA 4665520 →
CTM60C5CGS2+ furnace: Z8ES120C20LMPS1AHRI reference: 21864210517.008.10350002.26EPA 4665600 →
CTM60C5CGS2+ furnace: Z8ES120C20SMPS1AHRI reference: 21864210117.008.10350002.26EPA 4665604 →
CTM60C5CGS2+ furnace: Z9ET100C20SMPS1AHRI reference: 21864209317.008.10350002.24EPA 4665612 →
CTM60C5CGS2+ furnace: Z9ES100C20SMPS1AHRI reference: 21864208917.008.10350002.24EPA 4665616 →
CTU60C5XGS2+TXV+ furnace: Z8ET100C20LMPS1AHRI reference: 21864204517.008.10348002.26EPA 4665660 →
CTF60C5CGS2+ furnace: Z8ET100C20LMPS1AHRI reference: 21864204117.008.10348002.26EPA 4665664 →
CTU60C5XGS2+TXV+ furnace: Z9ES080C20SMPS1AHRI reference: 21864202117.008.10342002.20EPA 4665684 →
CTF60C5CGS2+ furnace: Z9ES080C20SMPS1AHRI reference: 21864201717.008.10342002.20EPA 4665688 →
CTF60D5CGS2+ furnace: Z9ET120D20SMPS1AHRI reference: 21864198117.008.10344002.24EPA 4665724 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →