CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

HH860E2S12

LX SERIES · source records, page 12

372 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range8.1–8.5BTU/Wh
Cooling capacity43,500–54,000BTU/h

Each efficiency range summarizes published EPA records for HH860E2S12. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 372 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18372 / 372
EER2 · BTU/Wh11–12372 / 372
HSPF2 · BTU/Wh8.1–8.5372 / 372
Cooling capacity · BTU/h43,500–54,000372 / 372
Heating capacity at 47°F / 8.3°C · BTU/h44,000–53,500372 / 372
Heating capacity at 17°F / −8.3°C · BTU/h40,000–45,500372 / 372
Heating capacity at 5°F / −15°C · BTU/h33,600–40,000372 / 372
COP at 5°F / −15°C2–2.32372 / 372
Equipment / loop typeHP - Split System372 / 372
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)372 / 372
Compressor stagingTwo-stage372 / 372
Connected capabilityNo372 / 372

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU60C5XGS2+TXV+ furnace: Z9ET100C20SMPS1AHRI reference: 21864243817.008.10350002.24EPA 4665267
CTF60C5CGS2+ furnace: Z9ET100C20SMPS1AHRI reference: 21864243317.008.10350002.24EPA 4665272
CTU60C5XGS2+TXV+ furnace: Z9ES100C20SMPS1AHRI reference: 21864242717.008.10350002.24EPA 4665278
CTF60C5CGS2+ furnace: Z9ES100C20SMPS1AHRI reference: 21864242117.008.10350002.24EPA 4665284
CTU60C5XGS2+TXV+ furnace: Z8ET120C20LMPS1AHRI reference: 21864234917.008.10344002.24EPA 4665356
CTF60C5CGS2+ furnace: Z8ET120C20LMPS1AHRI reference: 21864234217.008.10344002.24EPA 4665363
CTM60D5CGS2+ furnace: Z9ET120D20SMPS1AHRI reference: 21864225717.008.10344002.24EPA 4665448
CTU60C5XGS2+TXV+ furnace: Z8ES120C20LMPS1AHRI reference: 21864220317.008.10348002.24EPA 4665502
CTU60C5XGS2+TXV+ furnace: Z8ES120C20SMPS1AHRI reference: 21864219717.008.10348002.24EPA 4665508
CTF60C5CGS2+ furnace: Z8ES120C20LMPS1AHRI reference: 21864219117.008.10348002.24EPA 4665514
CTF60C5CGS2+ furnace: Z8ES120C20SMPS1AHRI reference: 21864218517.008.10348002.24EPA 4665520
CTM60C5CGS2+ furnace: Z8ES120C20LMPS1AHRI reference: 21864210517.008.10350002.26EPA 4665600
CTM60C5CGS2+ furnace: Z8ES120C20SMPS1AHRI reference: 21864210117.008.10350002.26EPA 4665604
CTM60C5CGS2+ furnace: Z9ET100C20SMPS1AHRI reference: 21864209317.008.10350002.24EPA 4665612
CTM60C5CGS2+ furnace: Z9ES100C20SMPS1AHRI reference: 21864208917.008.10350002.24EPA 4665616
CTU60C5XGS2+TXV+ furnace: Z8ET100C20LMPS1AHRI reference: 21864204517.008.10348002.26EPA 4665660
CTF60C5CGS2+ furnace: Z8ET100C20LMPS1AHRI reference: 21864204117.008.10348002.26EPA 4665664
CTU60C5XGS2+TXV+ furnace: Z9ES080C20SMPS1AHRI reference: 21864202117.008.10342002.20EPA 4665684
CTF60C5CGS2+ furnace: Z9ES080C20SMPS1AHRI reference: 21864201717.008.10342002.20EPA 4665688
CTF60D5CGS2+ furnace: Z9ET120D20SMPS1AHRI reference: 21864198117.008.10344002.24EPA 4665724

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →