Heating performance & equipment details
Ranges include the 585 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 585 / 585 |
| EER2 · BTU/Wh | 10–12 | 585 / 585 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 585 / 585 |
| Cooling capacity · BTU/h | 43,500–54,500 | 585 / 585 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 43,500–56,000 | 585 / 585 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 31,800–39,000 | 585 / 585 |
| Heating capacity at 5°F / −15°C · BTU/h | 32,000–40,500 | 585 / 585 |
| COP at 5°F / −15°C | 2 | 585 / 585 |
| Equipment / loop type | HP - Split System | 585 / 585 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 585 / 585 |
| Compressor staging | Continuously variable | 585 / 585 |
| Connected capability | No | 585 / 585 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF60C5CGS1+ furnace: TM9Y100C16MP11Cold climate designationAHRI reference: 214397400 | 17.00 | 9.00 | 33800 | 2.00 | EPA 3738964 → |
CTF60C5CGS1+ furnace: TM9V080C16MP12Cold climate designationAHRI reference: 214397499 | 17.00 | 9.00 | 33600 | 2.00 | EPA 3738973 → |
CTF60C5CGS1+ furnace: TP9C080C16MP13Cold climate designationAHRI reference: 214397504 | 17.00 | 9.00 | 33600 | 2.00 | EPA 3738978 → |
CTM60D5CGS1+ furnace: TM9E120D20MP12Cold climate designationAHRI reference: 214397511 | 17.00 | 9.00 | 34800 | 2.00 | EPA 3738985 → |
CTM60C5CGS1+ furnace: TM9Y100C20MP11Cold climate designationAHRI reference: 214398298 | 17.00 | 9.00 | 34800 | 2.00 | EPA 3739021 → |
CTF60C5CGS1+ furnace: TM9E080C20MP12Cold climate designationAHRI reference: 214397872 | 17.00 | 9.00 | 33800 | 2.00 | EPA 3739044 → |
CTM60C5CGS1+ furnace: TM9Y080C16MP11Cold climate designationAHRI reference: 214398630 | 17.00 | 9.00 | 33800 | 2.00 | EPA 3739066 → |
CTM60C5CGS1+ furnace: TM9E100C20MP12Cold climate designationAHRI reference: 214398679 | 17.00 | 9.00 | 33800 | 2.00 | EPA 3739074 → |
CTF60C5CGS1+ furnace: TM9Y100C20MP11Cold climate designationAHRI reference: 214398239 | 17.00 | 9.00 | 34000 | 2.00 | EPA 3739083 → |
CTF60D5CGS1+ furnace: TM9E120D20MP12Cold climate designationAHRI reference: 214397921 | 17.00 | 9.00 | 35000 | 2.00 | EPA 3739094 → |
CTU60C5XGS1+TXV+ furnace: TM9Y100C20MP11Cold climate designationAHRI reference: 214720172 | 17.00 | 9.00 | 34000 | 2.00 | EPA 3739149 → |
CTU60D5XGS1+TXV+ furnace: TM9E120D20MP12Cold climate designationAHRI reference: 214649911 | 17.00 | 9.00 | 35000 | 2.00 | EPA 3739154 → |
CTU60C5XGS1+TXV+ furnace: TM9V080C16MP12Cold climate designationAHRI reference: 214720034 | 17.00 | 9.00 | 33600 | 2.00 | EPA 3739174 → |
CTU60C5XGS1+TXV+ furnace: TP9C080C16MP13Cold climate designationAHRI reference: 214720041 | 17.00 | 9.00 | 33600 | 2.00 | EPA 3739182 → |
CTU60C5XGS1+TXV+ furnace: TM9Y080C16MP11Cold climate designationAHRI reference: 214719943 | 17.00 | 9.00 | 33800 | 2.00 | EPA 3739185 → |
CTU60C5XGS1+TXV+ furnace: TM9Y100C16MP11Cold climate designationAHRI reference: 214720157 | 17.00 | 9.00 | 33800 | 2.00 | EPA 3740305 → |
CTU60C5XGS1+TXV+ furnace: TM9E100C20MP12Cold climate designationAHRI reference: 214719984 | 17.00 | 9.00 | 33800 | 2.00 | EPA 3740339 → |
CTU60C5XGS1+TXV+ furnace: TM9E080C20MP12Cold climate designationAHRI reference: 214720024 | 17.00 | 9.00 | 33800 | 2.00 | EPA 3740344 → |
CTF60D5CGS1+ furnace: Z9ET120D20SMPS1Cold climate designationAHRI reference: 216374689 | 17.00 | 9.00 | 32600 | 2.00 | EPA 4047740 → |
CTU60D5XGS1+TXV+ furnace: Z9ET120D20SMPS1Cold climate designationAHRI reference: 216374730 | 17.00 | 9.00 | 32600 | 2.00 | EPA 4047766 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →