CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

HH860E2S11

LX SERIES · source records, page 25

585 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8.1–9.5BTU/Wh
Cooling capacity43,500–54,500BTU/h

Each efficiency range summarizes published EPA records for HH860E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 585 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19585 / 585
EER2 · BTU/Wh10–12585 / 585
HSPF2 · BTU/Wh8.1–9.5585 / 585
Cooling capacity · BTU/h43,500–54,500585 / 585
Heating capacity at 47°F / 8.3°C · BTU/h43,500–56,000585 / 585
Heating capacity at 17°F / −8.3°C · BTU/h31,800–39,000585 / 585
Heating capacity at 5°F / −15°C · BTU/h32,000–40,500585 / 585
COP at 5°F / −15°C2585 / 585
Equipment / loop typeHP - Split System585 / 585
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)585 / 585
Compressor stagingContinuously variable585 / 585
Connected capabilityNo585 / 585

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU60C5XGS2+TXV+ furnace: Z8ES120C20LMPS1AHRI reference: 21852428518.009.00334002.00EPA 4645624 →
CTU60C5XGS2+TXV+ furnace: Z8ES120C20SMPS1AHRI reference: 21852428118.009.00334002.00EPA 4645628 →
CTF60C5CGS2+ furnace: Z8ES120C20LMPS1AHRI reference: 21852427718.009.00334002.00EPA 4645632 →
CTF60C5CGS2+ furnace: Z8ES120C20SMPS1AHRI reference: 21852427318.009.00334002.00EPA 4645636 →
CTU60C5XGS2+TXV+ furnace: Z8ES100C16LMPS1AHRI reference: 21852426118.009.00332002.00EPA 4645648 →
CTU60C5XGS2+TXV+ furnace: Z8ES100C16SMPS1AHRI reference: 21852425718.009.00332002.00EPA 4645652 →
CTF60C5CGS2+ furnace: Z8ES100C16LMPS1AHRI reference: 21852425318.009.00332002.00EPA 4645656 →
CTF60C5CGS2+ furnace: Z8ES100C16SMPS1AHRI reference: 21852424918.009.00332002.00EPA 4645660 →
CTU60C5XGS2+TXV+ furnace: TP9C100C20MP13AHRI reference: 21852424318.009.00338002.00EPA 4645666 →
CTU60C5XGS2+TXV+ furnace: TM9V100C20MP12AHRI reference: 21852423918.009.00338002.00EPA 4645670 →
CTF60C5CGS2+ furnace: TP9C100C20MP13AHRI reference: 21852423318.009.00338002.00EPA 4645676 →
CTF60C5CGS2+ furnace: TM9V100C20MP12AHRI reference: 21852422918.009.00338002.00EPA 4645680 →
CTU60C5XGS2+TXV+ furnace: TM8V080C16MP12AHRI reference: 21852422518.009.00334002.00EPA 4645684 →
CTU60C5XGS2+TXV+ furnace: TM8V100C16MP12AHRI reference: 21852422118.009.00334002.00EPA 4645688 →
CTF60C5CGS2+ furnace: TM8V080C16MP12AHRI reference: 21852421718.009.00334002.00EPA 4645692 →
CTF60C5CGS2+ furnace: TM8V100C16MP12AHRI reference: 21852421318.009.00334002.00EPA 4645696 →
CTU60C5XGS2+TXV+ furnace: Z9ES100C16SMPS1AHRI reference: 21852420918.009.00342002.00EPA 4645700 →
CTF60C5CGS2+ furnace: Z9ES100C16SMPS1AHRI reference: 21852420518.009.00342002.00EPA 4645704 →
CTU60C5XGS2+TXV+ furnace: TL8E080C16UH11AHRI reference: 21852418118.009.00336002.00EPA 4645728 →
CTF60C5CGS2+ furnace: TL8E080C16UH11AHRI reference: 21852417718.009.00336002.00EPA 4645732 →