HH860E2S11
LX SERIES · source records, page 12
585 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH860E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 585 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 585 / 585 |
| EER2 · BTU/Wh | 10–12 | 585 / 585 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 585 / 585 |
| Cooling capacity · BTU/h | 43,500–54,500 | 585 / 585 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 43,500–56,000 | 585 / 585 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 31,800–39,000 | 585 / 585 |
| Heating capacity at 5°F / −15°C · BTU/h | 32,000–40,500 | 585 / 585 |
| COP at 5°F / −15°C | 2 | 585 / 585 |
| Equipment / loop type | HP - Split System | 585 / 585 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 585 / 585 |
| Compressor staging | Continuously variable | 585 / 585 |
| Connected capability | No | 585 / 585 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF60D5CHS2+ furnace: Z9ES120D20SMPS1AHRI reference: 218520791 | 19.00 | 8.50 | 38500 | 2.00 | EPA 4644773 → |
CTM60C5CGS2+JMC17C2SN1AHRI reference: 218524627 | 19.00 | 9.00 | 33400 | 2.00 | EPA 4645282 → |
CTM60C5CGS2+ furnace: Z9ET100C16SMPS1AHRI reference: 218524607 | 19.00 | 9.00 | 33200 | 2.00 | EPA 4645302 → |
CTM60C5CGS2+JMC16C2SN1AHRI reference: 218524589 | 19.00 | 9.00 | 33600 | 2.00 | EPA 4645320 → |
CTM60C5CGS2+JMVT16CC2N1AHRI reference: 218524585 | 19.00 | 9.00 | 33200 | 2.00 | EPA 4645324 → |
CTM60C5CGS2+JMVT17CC2N1AHRI reference: 218524561 | 19.00 | 9.50 | 33800 | 2.00 | EPA 4645348 → |
CTF60D5CGS2+JMVT20DC2N1AHRI reference: 218524529 | 19.00 | 9.50 | 33800 | 2.00 | EPA 4645380 → |
CTF60D5CGS2+JMC20D2SN1AHRI reference: 218524497 | 19.00 | 9.50 | 34000 | 2.00 | EPA 4645412 → |
CTU60C5XGS2+TXV+ furnace: Z8ET120C20LMPS1AHRI reference: 218524433 | 19.00 | 9.00 | 32000 | 2.00 | EPA 4645476 → |
CTF60C5CGS2+ furnace: Z8ET120C20LMPS1AHRI reference: 218524429 | 19.00 | 9.00 | 32000 | 2.00 | EPA 4645480 → |
CTU60C5XGS2+JMC16C2SN1+TXVAHRI reference: 218524269 | 19.00 | 9.00 | 33600 | 2.00 | EPA 4645640 → |
CTF60C5CGS2+JMC16C2SN1AHRI reference: 218524265 | 19.00 | 9.00 | 33600 | 2.00 | EPA 4645644 → |
CTU60C5XGS2+JMVT16CC2N1+TXVAHRI reference: 218524173 | 19.00 | 9.00 | 33600 | 2.00 | EPA 4645736 → |
CTF60C5CGS2+JMVT16CC2N1AHRI reference: 218524169 | 19.00 | 9.00 | 33600 | 2.00 | EPA 4645740 → |
CTU60C5XGS2+TXV+ furnace: Z9ET100C16SMPS1AHRI reference: 218524109 | 19.00 | 9.00 | 33200 | 2.00 | EPA 4645800 → |
CTF60C5CGS2+ furnace: Z9ET100C16SMPS1AHRI reference: 218524105 | 19.00 | 9.00 | 33200 | 2.00 | EPA 4645804 → |
CTF60D5CGS2+JME18D2SN2AHRI reference: 218637876 | 19.00 | 9.50 | 33800 | 2.00 | EPA 4663899 → |
CTM60C5CGS2+JME16C2SN2AHRI reference: 218637868 | 19.00 | 9.50 | 34000 | 2.00 | EPA 4663907 → |
CTU60C5XGS2+JME16C2SN2+TXVAHRI reference: 218637864 | 19.00 | 9.00 | 34200 | 2.00 | EPA 4663911 → |
CTF60C5CGS2+JME16C2SN2AHRI reference: 218637860 | 19.00 | 9.00 | 34200 | 2.00 | EPA 4663915 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.