CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

HH836E2S11

LX SERIES · source records, page 37

863 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8–9.5BTU/Wh
Cooling capacity31,600–35,000BTU/h

Each efficiency range summarizes published EPA records for HH836E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 863 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19863 / 863
EER2 · BTU/Wh10–12863 / 863
HSPF2 · BTU/Wh8–9.5863 / 863
Cooling capacity · BTU/h31,600–35,000863 / 863
Heating capacity at 47°F / 8.3°C · BTU/h30,000–33,400863 / 863
Heating capacity at 17°F / −8.3°C · BTU/h25,400–29,600863 / 863
Heating capacity at 5°F / −15°C · BTU/h22,200–27,200863 / 863
COP at 5°F / −15°C2–2.1863 / 863
Equipment / loop typeHP - Split System863 / 863
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)863 / 863
Compressor stagingContinuously variable863 / 863
Connected capabilityNo863 / 863

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM36B5ADS2+JMC12B2SN1AHRI reference: 21852259918.009.00248002.00EPA 4644858 →
CTM36B5CDS2+ furnace: Z8ES100B12LMPS1AHRI reference: 21852259518.008.50250002.00EPA 4644862 →
CTM36B5CDS2+ furnace: Z8ES100B12SMPS1AHRI reference: 21852259118.008.50250002.00EPA 4644866 →
CTM36B5ADS2+ furnace: Z8ES100B12LMPS1AHRI reference: 21852258718.008.50250002.00EPA 4644870 →
CTM36B5ADS2+ furnace: Z8ES100B12SMPS1AHRI reference: 21852258318.008.50250002.00EPA 4644874 →
CTM36B5CDS2+JMVT12BC2N1AHRI reference: 21852257918.009.00248002.00EPA 4644878 →
CTM36B5ADS2+JMVT12BC2N1AHRI reference: 21852257518.009.00248002.00EPA 4644882 →
CTM36B5CDS2+ furnace: Z9ES080B12SMPS1AHRI reference: 21852257118.008.50256002.00EPA 4644886 →
CTM36B5ADS2+ furnace: Z9ES080B12SMPS1AHRI reference: 21852256718.008.50256002.00EPA 4644890 →
CTM36B5CDS2+ furnace: Z8ES080B12LMPS1AHRI reference: 21852254318.008.50256002.00EPA 4644914 →
CTM36B5CDS2+ furnace: Z8ES080B12SMPS1AHRI reference: 21852253918.008.50256002.00EPA 4644918 →
CTM36B5ADS2+ furnace: Z8ES080B12LMPS1AHRI reference: 21852253518.008.50256002.00EPA 4644922 →
CTM36B5ADS2+ furnace: Z8ES080B12SMPS1AHRI reference: 21852253118.008.50256002.00EPA 4644926 →
CTU48C5XFS2+TXV+ furnace: Z9ES100C16SMPS1AHRI reference: 21852246318.009.00258002.00EPA 4644994 →
CTF48C5CFS2+ furnace: Z9ES100C16SMPS1AHRI reference: 21852245918.009.00258002.00EPA 4644998 →
CTU48C5XFS2+TXV+ furnace: TP9C080C16MP13AHRI reference: 21852243718.009.00254002.00EPA 4645020 →
CTU48C5XFS2+TXV+ furnace: TM9V080C16MP12AHRI reference: 21852243318.009.00254002.00EPA 4645024 →
CTF48C5CFS2+ furnace: TP9C080C16MP13AHRI reference: 21852242718.009.00254002.00EPA 4645030 →
CTF48C5CFS2+ furnace: TM9V080C16MP12AHRI reference: 21852242318.009.00254002.00EPA 4645034 →
CTF48C5AFS2+ furnace: Z9ES100C16SMPS1AHRI reference: 21858724118.009.00258002.00EPA 4650213 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →