CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

HH836E2S11

LX SERIES · source records, page 33

863 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8–9.5BTU/Wh
Cooling capacity31,600–35,000BTU/h

Each efficiency range summarizes published EPA records for HH836E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 863 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19863 / 863
EER2 · BTU/Wh10–12863 / 863
HSPF2 · BTU/Wh8–9.5863 / 863
Cooling capacity · BTU/h31,600–35,000863 / 863
Heating capacity at 47°F / 8.3°C · BTU/h30,000–33,400863 / 863
Heating capacity at 17°F / −8.3°C · BTU/h25,400–29,600863 / 863
Heating capacity at 5°F / −15°C · BTU/h22,200–27,200863 / 863
COP at 5°F / −15°C2–2.1863 / 863
Equipment / loop typeHP - Split System863 / 863
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)863 / 863
Compressor stagingContinuously variable863 / 863
Connected capabilityNo863 / 863

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM36C5CDS2+ furnace: Z9ES080C16SMPS1AHRI reference: 21852150918.008.50254002.00EPA 4644067 →
CTM36C5ADS2+ furnace: Z9ES080C16SMPS1AHRI reference: 21852150518.008.50254002.00EPA 4644071 →
CTM36C5CDS2+ furnace: TL9E080C16UH11AHRI reference: 21852150118.008.50268002.00EPA 4644075 →
CTM36C5ADS2+ furnace: TL9E080C16UH11AHRI reference: 21852149718.008.50268002.00EPA 4644079 →
CTM36C5CDS2+ furnace: TL8E080C16UH11AHRI reference: 21852149318.008.50264002.00EPA 4644083 →
CTM36C5ADS2+ furnace: TL8E080C16UH11AHRI reference: 21852148918.008.50264002.00EPA 4644087 →
CTM36C5CDS2+ furnace: Z8ES120C16LMPS1AHRI reference: 21852148518.008.50258002.00EPA 4644091 →
CTM36C5CDS2+ furnace: Z8ES120C16SMPS1AHRI reference: 21852148118.008.50258002.00EPA 4644095 →
CTM36C5ADS2+ furnace: Z8ES120C16LMPS1AHRI reference: 21852147718.008.50258002.00EPA 4644099 →
CTM36C5ADS2+ furnace: Z8ES120C16SMPS1AHRI reference: 21852147318.008.50258002.00EPA 4644103 →
CTM36C5CDS2+ furnace: Z9ES080C20SMPS1AHRI reference: 21852146918.008.50264002.00EPA 4644107 →
CTM36C5ADS2+ furnace: Z9ES080C20SMPS1AHRI reference: 21852146518.008.50264002.00EPA 4644111 →
CTM36C5CDS2+ furnace: Z8ES120C20LMPS1AHRI reference: 21852146118.008.50262002.00EPA 4644115 →
CTM36C5CDS2+ furnace: Z8ES120C20SMPS1AHRI reference: 21852145718.008.50262002.00EPA 4644119 →
CTM36C5ADS2+ furnace: Z8ES120C20LMPS1AHRI reference: 21852145318.008.50262002.00EPA 4644123 →
CTM36C5ADS2+ furnace: Z8ES120C20SMPS1AHRI reference: 21852144918.008.50262002.00EPA 4644127 →
CTM36C5CDS2+ furnace: Z8ES100C16LMPS1AHRI reference: 21852144518.008.50260002.00EPA 4644131 →
CTM36C5CDS2+ furnace: Z8ES100C16SMPS1AHRI reference: 21852144118.008.50260002.00EPA 4644135 →
CTM36C5ADS2+ furnace: Z8ES100C16LMPS1AHRI reference: 21852143718.008.50260002.00EPA 4644139 →
CTM36C5ADS2+ furnace: Z8ES100C16SMPS1AHRI reference: 21852143318.008.50260002.00EPA 4644143 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →