HH836E2S11
LX SERIES · source records, page 19
863 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH836E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 863 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 863 / 863 |
| EER2 · BTU/Wh | 10–12 | 863 / 863 |
| HSPF2 · BTU/Wh | 8–9.5 | 863 / 863 |
| Cooling capacity · BTU/h | 31,600–35,000 | 863 / 863 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 30,000–33,400 | 863 / 863 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 25,400–29,600 | 863 / 863 |
| Heating capacity at 5°F / −15°C · BTU/h | 22,200–27,200 | 863 / 863 |
| COP at 5°F / −15°C | 2–2.1 | 863 / 863 |
| Equipment / loop type | HP - Split System | 863 / 863 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 863 / 863 |
| Compressor staging | Continuously variable | 863 / 863 |
| Connected capability | No | 863 / 863 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM48C5AFS2+ furnace: Z9ES080C16SMPS1AHRI reference: 218586311 | 19.00 | 9.00 | 25800 | 2.00 | EPA 4650686 → |
CTM48C5AFS2+ furnace: TP9C100C16MP13AHRI reference: 218586286 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4650698 → |
CTM48C5AFS2+ furnace: TM9V100C16MP12AHRI reference: 218586271 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4650706 → |
CTM48C5AFS2+ furnace: Z8ES080C20LMPS1AHRI reference: 218586255 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4650714 → |
CTM48C5AFS2+ furnace: Z8ES080C20SMPS1AHRI reference: 218586239 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4650722 → |
CTM48C5AFS2+ furnace: Z8ES080C16LMPS1AHRI reference: 218586222 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4650731 → |
CTM48C5AFS2+ furnace: Z8ES080C16SMPS1AHRI reference: 218586207 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4650738 → |
CTM48C5AFS2+ furnace: TP9C080C16MP13AHRI reference: 218586184 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4650751 → |
CTM48C5AFS2+ furnace: TM9V080C16MP12AHRI reference: 218586168 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4650759 → |
CTM48C5AFS2+ furnace: Z8ES100C20LMPS1AHRI reference: 218586152 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4650768 → |
CTM48C5AFS2+ furnace: Z8ES100C20SMPS1AHRI reference: 218586136 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4650776 → |
CTM48C5AFS2+ furnace: TL8E100C20UH11AHRI reference: 218586121 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4650783 → |
CTM48C5AFS2+ furnace: TL8E080C16UH11AHRI reference: 218586110 | 19.00 | 9.00 | 25600 | 2.00 | EPA 4650787 → |
CTM48C5AFS2+ furnace: Z9ET100C16SMPS1AHRI reference: 218586088 | 19.00 | 9.50 | 23400 | 2.00 | EPA 4650795 → |
CTM48C5AFS2+ furnace: Z9ET080C16SMPS1AHRI reference: 218586076 | 19.00 | 9.50 | 24200 | 2.00 | EPA 4650799 → |
CTF36C5CDS2+JME16C2SN2AHRI reference: 218637578 | 19.00 | 9.00 | 25600 | 2.00 | EPA 4663935 → |
CTF36C5ADS2+JME16C2SN2AHRI reference: 218637572 | 19.00 | 9.00 | 25600 | 2.00 | EPA 4663941 → |
CTM36C5CDS2+JME16C2SN2AHRI reference: 218637566 | 19.00 | 9.00 | 25600 | 2.00 | EPA 4663947 → |
CTM36C5ADS2+JME16C2SN2AHRI reference: 218637560 | 19.00 | 9.00 | 25600 | 2.00 | EPA 4663953 → |
CTM48C5CFS2+JME12C2SN2AHRI reference: 218637554 | 19.00 | 9.00 | 25200 | 2.00 | EPA 4663959 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →