CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

HH824E2S12

LX SERIES · source records, page 2

238 published source records · source checked Sep 21, 2026

SEER2 range16–18BTU/Wh
HSPF2 range8.1–8.5BTU/Wh
Cooling capacity22,400–24,000BTU/h

Each efficiency range summarizes published EPA records for HH824E2S12. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 238 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–18238 / 238
EER2 · BTU/Wh11–12238 / 238
HSPF2 · BTU/Wh8.1–8.5238 / 238
Cooling capacity · BTU/h22,400–24,000238 / 238
Heating capacity at 47°F / 8.3°C · BTU/h22,000–24,000238 / 238
Heating capacity at 17°F / −8.3°C · BTU/h20,600–22,800238 / 238
Heating capacity at 5°F / −15°C · BTU/h17,200–18,700238 / 238
COP at 5°F / −15°C2.22–2.46238 / 238
Equipment / loop typeHP - Split System238 / 238
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)238 / 238
Compressor stagingTwo-stage238 / 238
Connected capabilityNo238 / 238

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF30B5ACS2+JME12B2SN2Cold climate designationAHRI reference: 21864326517.508.50175002.28EPA 4666864
CTU30B5XCS2+TXV+ furnace: Z8VT080B12SMPC1Cold climate designationAHRI reference: 21864322817.508.50181002.34EPA 4666901
CTF30B5ACS2+ furnace: Z8VT080B12SMPC1Cold climate designationAHRI reference: 21864322317.508.50181002.34EPA 4666906
JHE24B5AC2SS2Cold climate designationAHRI reference: 21864320417.508.50179002.32EPA 4666925
CTU36B5XDS1+TXV+ furnace: Z8VT080B12SMPC1Cold climate designationAHRI reference: 21869833717.508.50178002.40EPA 4684155
CTF36B5ADS1+ furnace: Z8VT080B12SMPC1Cold climate designationAHRI reference: 21869833317.508.50178002.40EPA 4684159
CTM36B5ADS1+ furnace: Z8ET080B12LMPS1Cold climate designationAHRI reference: 21869832117.508.50182002.42EPA 4684171
CTU36B5XDS1+TXV+ furnace: Z8ET080B12LMPS1Cold climate designationAHRI reference: 21869830117.508.50182002.42EPA 4684191
CTF36B5ADS1+ furnace: Z8ET080B12LMPS1Cold climate designationAHRI reference: 21869829717.508.50182002.42EPA 4684195
CTM36B5ADS1+ furnace: Z8VT080B12SMPC1Cold climate designationAHRI reference: 21869828517.508.50178002.40EPA 4684207
CTM30B5ACS1+ furnace: Z8VT080B12SMPC1Cold climate designationAHRI reference: 21869823717.508.50182002.32EPA 4684255
CTU30B5XCS1+TXV+ furnace: Z8ET080B12LMPS1Cold climate designationAHRI reference: 21869823317.508.50181002.32EPA 4684259
CTF30B5ACS1+ furnace: Z8ET080B12LMPS1Cold climate designationAHRI reference: 21869822917.508.50181002.32EPA 4684263
CTU30B5XCS1+TXV+ furnace: Z8VT080B12SMPC1Cold climate designationAHRI reference: 21869822517.508.50181002.34EPA 4684267
CTF30B5ACS1+ furnace: Z8VT080B12SMPC1Cold climate designationAHRI reference: 21869822117.508.50181002.34EPA 4684271
CTM30B5ACS2+ furnace: Z9ET080B12SMPS1Cold climate designationAHRI reference: 21864338417.008.50180002.26EPA 4665026
JHE36B5AD2SS2Cold climate designationAHRI reference: 21864363517.008.50176002.36EPA 4666540
CTF30A5ADS2+ furnace: Z9ES060A10SMPS1AHRI reference: 21864362317.008.10182002.32EPA 4666552
CTF30A5ADS2+ furnace: Z8VT060A12SMPC1Cold climate designationAHRI reference: 21864361117.008.50181002.40EPA 4666564
CTU36B5XDS2+TXV+ furnace: Z9ET080B12SMPS1Cold climate designationAHRI reference: 21864359917.008.50182002.38EPA 4666576

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →