CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

HH824E2S11

LX SERIES · source records, page 15

318 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8.5–9.5BTU/Wh
Cooling capacity23,000BTU/h

Each efficiency range summarizes published EPA records for HH824E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 318 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19318 / 318
EER2 · BTU/Wh11–12318 / 318
HSPF2 · BTU/Wh8.5–9.5318 / 318
Cooling capacity · BTU/h23,000318 / 318
Heating capacity at 47°F / 8.3°C · BTU/h23,000318 / 318
Heating capacity at 17°F / −8.3°C · BTU/h17,100–18,900318 / 318
Heating capacity at 5°F / −15°C · BTU/h17,200–19,400318 / 318
COP at 5°F / −15°C2318 / 318
Equipment / loop typeHP - Split System318 / 318
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)318 / 318
Compressor stagingContinuously variable318 / 318
Connected capabilityNo318 / 318

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF30A5ADS1+ furnace: Z9ET040A10SMPS1Cold climate designationAHRI reference: 21641116717.009.00172002.00EPA 3814926 →
CTM36B5ADS2+ furnace: Z9ES060B12SMPS1AHRI reference: 21852068517.009.50186002.00EPA 4642269 →
CTM36B5ADS2+ furnace: TP9C060B12MP13AHRI reference: 21852067917.009.00176002.00EPA 4642275 →
CTM36B5ADS2+ furnace: TM9V060B12MP12AHRI reference: 21852067517.009.00176002.00EPA 4642279 →
CTM36B5ADS2+ furnace: TM8V080B12MP12AHRI reference: 21852063317.009.00177002.00EPA 4642321 →
CTM30B5ACS2+ furnace: TM8V080B12MP12AHRI reference: 21852059717.009.50179002.00EPA 4642357 →
CTM30B5ACS2+ furnace: Z9ES060B12SMPS1AHRI reference: 21852059317.009.50192002.00EPA 4642361 →
CTM30B5ACS2+ furnace: TL9E060B12UH11AHRI reference: 21852058917.009.50183002.00EPA 4642365 →
CTM30B5ACS2+ furnace: TP9C080B12MP13AHRI reference: 21852057517.009.50178002.00EPA 4642379 →
CTM30B5ACS2+ furnace: TM9V080B12MP12AHRI reference: 21852057117.009.50178002.00EPA 4642383 →
CTM30B5ACS2+ furnace: TP9C060B12MP13AHRI reference: 21852056517.009.50180002.00EPA 4642389 →
CTM30B5ACS2+ furnace: TM9V060B12MP12AHRI reference: 21852056117.009.50180002.00EPA 4642393 →
CTU36B5XDS2+TXV+ furnace: Z9ES060B12SMPS1AHRI reference: 21852048917.009.50187002.00EPA 4642465 →
CTF36B5ADS2+ furnace: Z9ES060B12SMPS1AHRI reference: 21852048517.009.50187002.00EPA 4642469 →
CTU30B5XCS2+TXV+ furnace: TP9C080B12MP13AHRI reference: 21852035917.009.50182002.00EPA 4642595 →
CTU30B5XCS2+TXV+ furnace: TM9V080B12MP12AHRI reference: 21852035517.009.50182002.00EPA 4642599 →
CTF30B5ACS2+ furnace: TP9C080B12MP13AHRI reference: 21852034917.009.50182002.00EPA 4642605 →
CTF30B5ACS2+ furnace: TM9V080B12MP12AHRI reference: 21852034517.009.50182002.00EPA 4642609 →
CTU30B5XCS2+TXV+ furnace: TM8V080B12MP12AHRI reference: 21852033317.009.50179002.00EPA 4642621 →
CTF30B5ACS2+ furnace: TM8V080B12MP12AHRI reference: 21852032917.009.50179002.00EPA 4642625 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →