Century / AIR-SOURCE HEAT PUMP

HSA1936V1-**A

HSA19 Series · source records, page 3

71 published source records · source checked Sep 21, 2026

SEER2 range15.2–20BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity21,600–35,200BTU/h

Each efficiency range summarizes published EPA records for HSA1936V1-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 71 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–2071 / 71
EER2 · BTU/Wh11–13.271 / 71
HSPF2 · BTU/Wh7.8–8.571 / 71
Cooling capacity · BTU/h21,600–35,20071 / 71
Heating capacity at 47°F / 8.3°C · BTU/h22,800–36,00071 / 71
Heating capacity at 17°F / −8.3°C · BTU/h14,600–21,60071 / 71
Heating capacity at 5°F / −15°C · BTU/h13,700–17,00071 / 71
COP at 5°F / −15°C1.48–2.1271 / 71
Equipment / loop typeHP - Split System71 / 71
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)71 / 71
Compressor stagingContinuously variable71 / 71
Connected capabilityNo71 / 71

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EH30BX-**+TDR+ furnace: GUH92C045B3MPAHRI reference: 21750428717.508.50152001.88EPA 4468607 →
7EH30BX-**+TDR+ furnace: GUH92C070B3MPAHRI reference: 21750428917.508.50151001.90EPA 4468610 →
7EH30BX-**+TDR+ furnace: GUH97T045B3MPAHRI reference: 21750429417.508.20151001.90EPA 4468614 →
7EH30AX-**+TDR+ furnace: GUH80X040A3MPAHRI reference: 21750430917.507.80149001.50EPA 4468634 →
7EH30AX-**+TDR+ furnace: GUH80X060A3MPAHRI reference: 21750431117.507.80149001.50EPA 4468636 →
7EH30AX-**+TDR+ furnace: GUH80C070A3MPAHRI reference: 21750431317.507.80145001.48EPA 4468639 →
7EH36CX-**+TDR+ furnace: GUH97T110C5MPAHRI reference: 21750406317.008.10164002.08EPA 4468487 →
7EH30BX-**+TDR+ furnace: GUH80C070B3MPAHRI reference: 21750428417.008.50151001.90EPA 4468605 →
7EH30BX-**+TDR+ furnace: GUH96C070B3MPAHRI reference: 21750429217.008.50151001.90EPA 4468612 →
7EH36CX-**+TDR+ furnace: GUH97T090C3MPAHRI reference: 21754745217.008.10165002.06EPA 4469837 →
7E[C,U]36BX-**+TDR+ furnace: GUH80X080B4MPAHRI reference: 21750401916.508.20148001.92EPA 4468451 →
7E[C,U]30BX-**+TDRAHRI reference: 21750424216.508.00144001.82EPA 4468466 →
7EH36CX-**+TDR+ furnace: GUH92C090C4MPAHRI reference: 21750406016.508.20162002.08EPA 4468482 →
7EH36CX-**+TDR+ furnace: GUH92C110C4MPAHRI reference: 21750406116.508.20162002.08EPA 4468484 →
HMA24PX1*-**AHRI reference: 21750418816.508.20156001.74EPA 4468547 →
7E[C,U]30AX-**+TDRAHRI reference: 21750429616.508.00144001.82EPA 4468623 →
7EH36CX-**+TDR+ furnace: GUH96C090C4MPAHRI reference: 21750562516.508.20163002.08EPA 4469118 →
7EH30BX-**+TDR+ furnace: GUH96C045B3MPAHRI reference: 21750429016.508.20153001.88EPA 4469407 →
7E[C,U]36AX-**+TDRAHRI reference: 21750401616.008.20157001.84EPA 4468452 →
7E[C,U]30/36BX-**+TDR+ furnace: GUH80C090B4MPAHRI reference: 21750403216.008.00163001.92EPA 4468463 →