Century / AIR-SOURCE HEAT PUMP

HSA1430S1-**A

HSA14 SERIES · HSA14 Series

12 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity28,800–29,600BTU/h

Each efficiency range summarizes published EPA records for HSA1430S1-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 12 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1612 / 12
EER2 · BTU/Wh12.6–13.412 / 12
HSPF2 · BTU/Wh7.8–8.212 / 12
Cooling capacity · BTU/h28,800–29,60012 / 12
Heating capacity at 47°F / 8.3°C · BTU/h26,600–28,20012 / 12
Heating capacity at 17°F / −8.3°C · BTU/h17,100–18,30012 / 12
Heating capacity at 5°F / −15°C · BTU/h12,600–14,30012 / 12
COP at 5°F / −15°C1.92–2.1212 / 12
Equipment / loop typeHP - Split System12 / 12
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)12 / 12
Compressor stagingSingle stage12 / 12
Connected capabilityNo12 / 12

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7E[C,U]36BX-**+TDR+ furnace: GUH80C090B4MP*AHRI reference: 21637259616.007.80134001.98EPA 3813546
7EH30BX-**+TDR+ furnace: GUH80C070B3MP*AHRI reference: 21637259815.507.80134001.96EPA 3813548
7EH30BX-**+TDR+ furnace: GUH80C090B4MP*AHRI reference: 21637259915.507.80135001.98EPA 3813549
HMA30VX1*-**AHRI reference: 21637259415.507.80126001.94EPA 3813726
7EH30BX-**+TDR+ furnace: GUH97T045B3MP*AHRI reference: 21649882115.507.80135001.96EPA 3847492
HMA30CX1*-**AHRI reference: 21766272915.507.80127001.92EPA 4497281
HMAS36CX1S-**AHRI reference: 21842647515.508.10136001.99EPA 4609754
7EH30BX-**+TDR+ furnace: GUH80X080B4MP*AHRI reference: 21637259715.207.80137001.94EPA 3813547
7EH30BX-**+TDR+ furnace: GUH92C070B3MP*AHRI reference: 21637260015.207.80137001.96EPA 3813550
7EH30BX-**+TDR+ furnace: GUH96C070B3MP*AHRI reference: 21637260115.207.80136001.96EPA 3813551
HMA36VX1*-**AHRI reference: 21637259515.208.20143002.12EPA 3813760
HMA36CX1*-**AHRI reference: 21766273015.208.20143002.12EPA 4497282

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →