HRG1**8S1R-**A
HRG15 Series · source records, page 2
32 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HRG1**8S1R-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 32 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16.8 | 32 / 32 |
| EER2 · BTU/Wh | 12.5–14 | 32 / 32 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 32 / 32 |
| Cooling capacity · BTU/h | 18,000 | 32 / 32 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 17,000–18,000 | 32 / 32 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 10,400–11,200 | 32 / 32 |
| Heating capacity at 5°F / −15°C · BTU/h | 7,600–8,400 | 32 / 32 |
| COP at 5°F / −15°C | 1.92–2.1 | 32 / 32 |
| Equipment / loop type | HP - Split System | 32 / 32 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 32 / 32 |
| Compressor staging | Single stage | 32 / 32 |
| Connected capability | No | 32 / 32 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EAH1P24B*+TDR+TXV+ furnace: GUH97M070B3MAHRI reference: 211734648 | 16.40 | 8.10 | 8400 | 2.10 | EPA 2467497 → |
EAH1P24B*+TDR+TXV+ furnace: GUH92C045B3MAHRI reference: 211734565 | 16.40 | 8.10 | 8200 | 2.08 | EPA 2467504 → |
EAH1P30B*+TDR+TXV+ furnace: GUH96C070B3MAHRI reference: 211734845 | 16.40 | 7.80 | 7700 | 2.00 | EPA 2468379 → |
EA(C;U)1P24A+TDR+TXV+ furnace: GUH80C045A3MAHRI reference: 210331442 | 16.20 | 8.00 | 8200 | 2.08 | EPA 2457329 → |
EA(C;U)1P24A+TDR+TXV+ furnace: GUH92C070B3MAHRI reference: 210331446 | 16.20 | 8.10 | 8200 | 2.10 | EPA 2457508 → |
EA(C;U)1P24A+TDR+TXV+ furnace: GUH92C045B3MAHRI reference: 210331445 | 16.00 | 8.00 | 8200 | 2.06 | EPA 2456209 → |
EA(C;U)1P24A+TDR+TXV+ furnace: GUH96C045B3MAHRI reference: 210331444 | 16.00 | 8.00 | 8200 | 2.04 | EPA 2457116 → |
EA(C;U)1P24A+TDR+TXV+ furnace: GUH96C070B3MAHRI reference: 210331447 | 16.00 | 8.00 | 8200 | 2.08 | EPA 2457307 → |
EAH1P24B*+TDR+TXV+ furnace: GUH96C045B3MAHRI reference: 211734610 | 16.00 | 8.10 | 8200 | 2.06 | EPA 2463640 → |
EAH1P24B*+TDR+TXV+ furnace: GUH96C070B3MAHRI reference: 211734622 | 16.00 | 8.10 | 8200 | 2.06 | EPA 2464457 → |
EAH1P30B*+TDR+TXV+ furnace: GUH80C090B4MAHRI reference: 211734758 | 15.60 | 7.80 | 8000 | 1.92 | EPA 2466623 → |
EA(C;U)1P30A+TDR+TXV+ furnace: GUH80C090B4MAHRI reference: 210331463 | 15.20 | 7.80 | 8100 | 1.94 | EPA 2456249 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →