Carrier / AIR-SOURCE HEAT PUMP

GH8TAN560**AA*

2-STAGE 18 SEER HP · source records, page 2

131 published source records · source checked Sep 21, 2026

SEER2 range15.5–17.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity54,000–58,000BTU/h

Each efficiency range summarizes published EPA records for GH8TAN560**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 131 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–17.5131 / 131
EER2 · BTU/Wh11.7–13131 / 131
HSPF2 · BTU/Wh7.8–8.5131 / 131
Cooling capacity · BTU/h54,000–58,000131 / 131
Heating capacity at 47°F / 8.3°C · BTU/h56,500–61,500131 / 131
Heating capacity at 17°F / −8.3°C · BTU/h36,200–38,500131 / 131
Heating capacity at 5°F / −15°C · BTU/h29,600–31,800131 / 131
COP at 5°F / −15°C2.1–2.34131 / 131
Equipment / loop typeHP - Split System131 / 131
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)131 / 131
Compressor stagingTwo-stage131 / 131
Connected capabilityNo131 / 131

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**6121AM*+ furnace: 58TN*B110C21**20AHRI reference: 21562968716.508.00304002.25EPA 3951758
CAA**6121AM*+ furnace: 58TP*B110V21**22AHRI reference: 21562971716.508.00300002.30EPA 3951789
CAA**6124AM*+ furnace: 59TP6C100V21**22AHRI reference: 21563043516.508.10298002.14EPA 3951942
CAA**6124AM*+ furnace: OVLAAB060154AHRI reference: 21563046616.508.00304002.25EPA 3951972
CAA**6124AM*+ furnace: 59SU5B100M21**22AHRI reference: 21563034316.508.00302002.25EPA 3952116
CAA**6124AM*+ furnace: 59TP7A100V21**22AHRI reference: 21571862816.508.00298002.30EPA 3997711
CAA**6121AM*+ furnace: 59TP7A100V21**22AHRI reference: 21571851116.508.00300002.30EPA 3997724
F55AA*D60L*AHRI reference: 21646429916.008.10302002.30EPA 3847211
CVAMA6124XMA*+ furnace: 58TP*B135V24**22AHRI reference: 21562666516.008.50314002.34EPA 3949862
CVAMA6124XMA*+ furnace: 59TP6C100V21**22AHRI reference: 21562691216.008.50316002.34EPA 3949870
CVAVA6021XMA*+ furnace: 58SP*B090V21**20AHRI reference: 21562698516.008.10304002.20EPA 3949882
CVAVA6021XMA*+ furnace: 58SP*B110V21**22AHRI reference: 21562699816.008.10304002.20EPA 3949897
CVAVA6021XMA*+ furnace: 58SU*B060M17**16AHRI reference: 21562701116.008.10306002.22EPA 3949910
CVAVA6021XMA*+ furnace: 58SU*B080M21**20AHRI reference: 21562703016.008.10304002.22EPA 3949929
CVAVA6021XMA*+ furnace: 58SU*B100M21**20AHRI reference: 21562704916.008.10304002.22EPA 3949947
CVAVA6021XMA*+ furnace: 58TN*B090C21**20AHRI reference: 21562708216.008.10304002.22EPA 3949969
CVAVA6021XMA*+ furnace: 58TP*B090V21**20AHRI reference: 21562711016.008.10304002.20EPA 3950067
CVAVA6021XMA*+ furnace: 58TP*B110V21**22AHRI reference: 21562712616.008.10304002.22EPA 3950084
CVAVA6021XMA*+ furnace: 59CU5B100C21**22AHRI reference: 21562715816.008.10306002.20EPA 3950101
CVAVA6021XMA*+ furnace: 59SU5B100M21**22AHRI reference: 21562727816.008.10302002.22EPA 3950114