Carrier / AIR-SOURCE HEAT PUMP

GH8TAN548**AA*

2-STAGE 18 SEER HP · source records, page 7

432 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for GH8TAN548**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 432 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18432 / 432
EER2 · BTU/Wh11.7–13.5432 / 432
HSPF2 · BTU/Wh7.8–8.5432 / 432
Cooling capacity · BTU/h45,500–50,500432 / 432
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500432 / 432
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600432 / 432
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600432 / 432
COP at 5°F / −15°C2.06–2.32432 / 432
Equipment / loop typeHP - Split System432 / 432
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)432 / 432
Compressor stagingTwo-stage432 / 432
Connected capabilityNo432 / 432

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAVA6121XMA*+ furnace: 58CU*B100C21**20AHRI reference: 21572232217.008.00252002.24EPA 3982528
CVAVA6121XMA*+ furnace: 59TN7A100C21**22AHRI reference: 21572235017.008.00254002.10EPA 3982554
CVAVA6121XMA*+ furnace: 59TP7A080V21**20AHRI reference: 21572236417.008.00250002.10EPA 3982577
CVAVA6121XMA*+ furnace: 59TP7A100V21**20AHRI reference: 21572238017.008.00250002.12EPA 3982589
CVAVA6124XMA*+ furnace: 59TN7A100C21**22AHRI reference: 21572245317.008.00252002.12EPA 3982654
CVAVA6124XMA*+ furnace: 59TN7A120C24**22AHRI reference: 21572246717.008.00252002.12EPA 3982676
CVAVA6124XMA*+ furnace: 59TP7A080V21**20AHRI reference: 21572248117.008.00256002.10EPA 3982698
CVAVA6124XMA*+ furnace: 59TP7A100V21**20AHRI reference: 21572249717.008.00252002.12EPA 3982700
CVAMA4821XMA*+ furnace: 58SP*B090V21**20AHRI reference: 21562290716.508.10244002.12EPA 3947311
CVAMA4821XMA*+ furnace: 58SP*B110V21**22AHRI reference: 21562292016.508.10244002.14EPA 3947326
CVAMA4821XMA*+ furnace: 58SU*B060M17**16AHRI reference: 21562293316.508.10246002.12EPA 3947339
CVAMA4821XMA*+ furnace: 58SU*B100M21**20AHRI reference: 21562297116.508.10246002.12EPA 3947378
CVAMA4821XMA*+ furnace: 58TN*B090C21**20AHRI reference: 21562300416.508.10244002.14EPA 3947407
CVAMA4821XMA*+ furnace: 58TN*B110C21**20AHRI reference: 21562301816.508.10244002.12EPA 3947421
CVAMA4821XMA*+ furnace: 58TP*B090V21**20AHRI reference: 21562303216.508.10244002.12EPA 3947438
CVAMA4821XMA*+ furnace: 58TP*B110V21**22AHRI reference: 21562304816.508.10244002.14EPA 3947455
CVAMA4821XMA*+ furnace: 59SU5B100M21**20AHRI reference: 21562315416.508.10244002.12EPA 3947498
CVAMA4821XMA*+ furnace: 59SU5B100M21**22AHRI reference: 21562317316.508.10246002.12EPA 3947517
CVAMA4821XMA*+ furnace: 59TP6C100V21**22AHRI reference: 21562325116.508.10242002.12EPA 3947577
CVAMA4921XMA*+ furnace: 58TN*B070C21**20AHRI reference: 21562334716.508.10256002.08EPA 3947671