Carrier / AIR-SOURCE HEAT PUMP

GH8TAN548**AA*

2-STAGE 18 SEER HP · source records, page 2

432 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for GH8TAN548**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 432 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18432 / 432
EER2 · BTU/Wh11.7–13.5432 / 432
HSPF2 · BTU/Wh7.8–8.5432 / 432
Cooling capacity · BTU/h45,500–50,500432 / 432
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500432 / 432
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600432 / 432
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600432 / 432
COP at 5°F / −15°C2.06–2.32432 / 432
Equipment / loop typeHP - Split System432 / 432
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)432 / 432
Compressor stagingTwo-stage432 / 432
Connected capabilityNo432 / 432

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAVA6124XMA*+ furnace: 58SP*B110V21**22AHRI reference: 21562539417.508.50250002.24EPA 3949766
CVAVA6124XMA*+ furnace: 58TN*B135C24**22AHRI reference: 21562546717.508.50248002.28EPA 3949803
CVAVA6124XMA*+ furnace: 58TP*B110V21**22AHRI reference: 21562549717.508.50248002.28EPA 3949833
CVAVA6124XMA*+ furnace: 59TP6C100V21**22AHRI reference: 21562574817.508.50248002.26EPA 3950140
CVAMA6021XMA*+ furnace: 59TP7A100V21**22AHRI reference: 21572209217.508.00244002.14EPA 3981740
CVAVA6021XMA*+ furnace: 59TP7A100V21**22AHRI reference: 21572229517.508.00244002.14EPA 3982505
CVAVA6121XMA*+ furnace: 58CU*B080C21**20AHRI reference: 21572230817.508.00248002.26EPA 3982518
CVAVA6121XMA*+ furnace: 59TP7A100V21**22AHRI reference: 21572239817.508.50246002.28EPA 3982611
CVAVA6124XMA*+ furnace: 58CU*B080C21**20AHRI reference: 21572241117.508.00246002.28EPA 3982615
CVAVA6124XMA*+ furnace: 59TP7A100V21**22AHRI reference: 21572251517.508.50248002.26EPA 3982729
FT5BD4821X*AHRI reference: 21869542317.508.10254002.18EPA 4683404
CVAMA4821XMA*+ furnace: 58SU*B080M21**20AHRI reference: 21562295217.008.10240002.14EPA 3947356
CVAMA4921XMA*+ furnace: 58SP*B090V21**20AHRI reference: 21562326417.008.10250002.10EPA 3947589
CVAMA4921XMA*+ furnace: 58SP*B110V21**22AHRI reference: 21562327717.008.10246002.12EPA 3947601
CVAMA4921XMA*+ furnace: 58SU*B060M17**16AHRI reference: 21562329017.008.10250002.12EPA 3947614
CVAMA4921XMA*+ furnace: 58SU*B100M21**20AHRI reference: 21562332817.008.10248002.10EPA 3947651
CVAMA4921XMA*+ furnace: 58TN*B090C21**20AHRI reference: 21562336117.008.10252002.10EPA 3947686
CVAMA4921XMA*+ furnace: 58TN*B110C21**20AHRI reference: 21562337517.008.10250002.10EPA 3947700
CVAMA4921XMA*+ furnace: 58TP*B090V21**20AHRI reference: 21562338917.008.10250002.10EPA 3947714
CVAMA4921XMA*+ furnace: 58TP*B110V21**22AHRI reference: 21562340517.008.10248002.12EPA 3947727

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →