Carrier / AIR-SOURCE HEAT PUMP

GH8TAN548**AA*

2-STAGE 18 SEER HP · source records, page 17

432 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for GH8TAN548**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 432 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18432 / 432
EER2 · BTU/Wh11.7–13.5432 / 432
HSPF2 · BTU/Wh7.8–8.5432 / 432
Cooling capacity · BTU/h45,500–50,500432 / 432
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500432 / 432
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600432 / 432
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600432 / 432
COP at 5°F / −15°C2.06–2.32432 / 432
Equipment / loop typeHP - Split System432 / 432
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)432 / 432
Compressor stagingTwo-stage432 / 432
Connected capabilityNo432 / 432

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**6124AM*+ furnace: 59TN6C100C21**22AHRI reference: 21563315416.008.10266002.16EPA 3953547 →
CAA**6124AM*+ furnace: 59MN7C100C21**22AHRI reference: 21563302116.008.10266002.16EPA 3953592 →
CAA**6124AM*+ furnace: 59SP6B120V24**22AHRI reference: 21563307516.008.10262002.20EPA 3953632 →
CAA**6124AM*+ furnace: 59SU5B100M21**20AHRI reference: 21563310716.008.10260002.20EPA 3953644 →
CSAH*4812AM*+ furnace: 58TP*B090V21**20AHRI reference: 21563352816.008.00250002.20EPA 3953665 →
CSAH*4812AM*+ furnace: 58TP*B110V21**22AHRI reference: 21563354416.008.00250002.20EPA 3953679 →
CSAH*4812AM*+ furnace: 58TP*B135V24**22AHRI reference: 21563356216.008.00248002.20EPA 3953695 →
CSAH*4812AM*+ furnace: 59TP6C100V21**20AHRI reference: 21563391716.008.00252002.20EPA 3953734 →
CSAH*4812AM*+ furnace: GG96VTAB60100C**AHRI reference: 21563391816.008.00252002.20EPA 3953735 →
CSAH*4812AM*+ furnace: 58SP*B090V21**20AHRI reference: 21563333216.008.00250002.20EPA 3953760 →
CSAH*4812AM*+ furnace: 58SP*B110V21**22AHRI reference: 21563334516.008.00250002.20EPA 3953772 →
CSAH*4812AM*+ furnace: 58TN*B110C21**20AHRI reference: 21563348416.008.00248002.20EPA 3953825 →
CSAH*4812AM*+ furnace: 58TN*B135C24**22AHRI reference: 21563349816.008.00248002.20EPA 3953840 →
CSAH*4812AM*+ furnace: 59TP6C100V21**22AHRI reference: 21563393616.008.00248002.25EPA 3953871 →
CSAH*6012AM*+ furnace: 58SP*B090V21**20AHRI reference: 21563405016.008.00250002.25EPA 3953898 →
CSAH*6012AM*+ furnace: 58SP*B110V21**22AHRI reference: 21563406316.008.00250002.25EPA 3953912 →
CSAH*6012AM*+ furnace: 59TN6C080C21**20AHRI reference: 21563453616.008.00252002.20EPA 3953941 →
CSAH*6012AM*+ furnace: 59TN6C100C21**22AHRI reference: 21563455016.008.00252002.25EPA 3953951 →
CSAH*6012AM*+ furnace: 59TN6C120C24**22AHRI reference: 21563456416.008.00254002.20EPA 3953959 →
CSAH*6012AM*+ furnace: 59TP6C080V21**20AHRI reference: 21563461816.008.00252002.20EPA 3953982 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →