Carrier / AIR-SOURCE HEAT PUMP

GH8TAN536**AA*

2-STAGE 18 SEER HP · source records, page 5

285 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–38,000BTU/h

Each efficiency range summarizes published EPA records for GH8TAN536**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 285 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17285 / 285
EER2 · BTU/Wh11.7–13285 / 285
HSPF2 · BTU/Wh7.8–8.5285 / 285
Cooling capacity · BTU/h33,800–38,000285 / 285
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000285 / 285
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200285 / 285
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600285 / 285
COP at 5°F / −15°C1.78–2.48285 / 285
Equipment / loop typeHP - Split System285 / 285
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)285 / 285
Compressor stagingTwo-stage285 / 285
Connected capabilityNo285 / 285

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**3717AM*+ furnace: 58SU*B040M17**12AHRI reference: 21563520915.508.10188002.26EPA 3954556 →
CAA**3721AM*+ furnace: 58SP*B090V21**20AHRI reference: 21563567015.508.10193002.26EPA 3954565 →
CAA**3721AM*+ furnace: 58SU*B040M17**12AHRI reference: 21563569615.508.10193002.26EPA 3954595 →
CAA**3721AM*+ furnace: 58SU*B080M21**20AHRI reference: 21563573015.508.10191002.42EPA 3954625 →
CAA**3721AM*+ furnace: 58SU*B100M21**20AHRI reference: 21563574715.508.10194002.26EPA 3954644 →
CAA**3721AM*+ furnace: 58TN*B070C21**20AHRI reference: 21563579215.508.10194002.24EPA 3954675 →
CAA**3721AM*+ furnace: 58TN*B090C17**16AHRI reference: 21563580615.508.10194002.24EPA 3954691 →
CAA**3721AM*+ furnace: 58TN*B090C21**20AHRI reference: 21563582015.508.10193002.26EPA 3954705 →
CAA**3721AM*+ furnace: 58TN*B110C21**20AHRI reference: 21563583415.508.10193002.24EPA 3954721 →
CAA**3721AM*+ furnace: 58TP*B090V17**16AHRI reference: 21563586415.508.10193002.26EPA 3954745 →
CAA**3721AM*+ furnace: 58TP*B090V21**20AHRI reference: 21563587215.508.10193002.26EPA 3954752 →
CAA**3721AM*+ furnace: 58TP*B110V21**22AHRI reference: 21563588815.508.10195002.24EPA 3954776 →
CAA**3721AM*+ furnace: 59CU5B080C21**20AHRI reference: 21563591815.508.10193002.24EPA 3954785 →
CAA**3717AM*+ furnace: 58SU*B060M17**16AHRI reference: 21563522815.508.10188002.28EPA 3954800 →
CAA**3721AM*+ furnace: 59MN7C100C21**22AHRI reference: 21563600215.508.10193002.24EPA 3954933 →
CAA**3721AM*+ furnace: 59SP6B080V21**20AHRI reference: 21563604215.508.10193002.26EPA 3954950 →
CAA**3721AM*+ furnace: 59CU5B100C21**22AHRI reference: 21563593215.508.10193002.24EPA 3954972 →
CAA**3721AM*+ furnace: 59SP6B100V21**20AHRI reference: 21563605515.508.10194002.26EPA 3954979 →
CAA**3721AM*+ furnace: 59MN7C080C21**20AHRI reference: 21563598815.508.10193002.26EPA 3954994 →
CAA**3721AM*+ furnace: 59SU5B080M21**20AHRI reference: 21563608615.508.10193002.26EPA 3955024 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.