Carrier / AIR-SOURCE HEAT PUMP

GH8TAN524**AA*

2-STAGE 18 SEER HP · source records, page 29

580 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for GH8TAN524**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 580 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5580 / 580
EER2 · BTU/Wh11.5–14580 / 580
HSPF2 · BTU/Wh7.8–8.5580 / 580
Cooling capacity · BTU/h22,200–25,000580 / 580
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400580 / 580
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000580 / 580
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500580 / 580
COP at 5°F / −15°C1.9–2.24580 / 580
Equipment / loop typeHP - Split System580 / 580
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)580 / 580
Compressor stagingTwo-stage580 / 580
Connected capabilityNo580 / 580

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CSAH*3012AM*+ furnace: 59TP7A060V17**16AHRI reference: 21572107915.507.80111002.06EPA 3981031 →
CSAH*3012AM*+ furnace: 59TP7A080V21**20AHRI reference: 21572111515.507.80111002.06EPA 3981074 →
CSAH*3012AM*+ furnace: 59TP7A100V21**20AHRI reference: 21572113115.507.80110002.08EPA 3981952 →
CSAH*2412AM*+ furnace: OVMAAB042112AHRI reference: 21565025615.507.80115001.95EPA 3996907 →
CSAH*2412AM*+ furnace: OVLAAB036098AHRI reference: 21565021815.507.80111002.00EPA 3997210 →
CSAH*2412AM*+ furnace: 59CU5B100C21**22AHRI reference: 21564943315.508.00111002.05EPA 3997272 →
CSAH*2412AM*+ furnace: 58CU*B100C21**20AHRI reference: 21571289915.507.80111002.00EPA 3997549 →
CAA**2414AM*+ furnace: 59TN7A040C14**10AHRI reference: 21799184815.508.00113002.00EPA 4566311 →
CAA**2414AM*+ furnace: 59TP7A040V14**10AHRI reference: 21799164915.508.00112002.02EPA 4566596 →
CAA**2414AM*+ furnace: GG97VTAA30040A**AHRI reference: 21799165015.508.00112002.02EPA 4566597 →
CAA**2417AM*+ furnace: 59TP7A040V14**10AHRI reference: 21799166915.508.00113001.98EPA 4566616 →
CAA**2417AM*+ furnace: GG97VTAA30040A**AHRI reference: 21799167015.508.00113001.98EPA 4566617 →
CAA**2417AM*+ furnace: 59TN6C040C14**10AHRI reference: 21564410515.208.00113002.02EPA 3957586 →
CSAH*2412AM*+ furnace: 59SP6B040V14**10AHRI reference: 21564958115.208.00112001.90EPA 3962121 →
CSAH*3012AM*+ furnace: OVLAAB036098AHRI reference: 21565168515.208.00115002.00EPA 3964305 →
CSAH*2412AM*+ furnace: 59SP6B040V17**12AHRI reference: 21564960015.208.00112001.90EPA 3996849 →
CSAH*2412AM*+ furnace: 59TP6C040V17**12AHRI reference: 21565001615.208.00112001.90EPA 3997158 →
CSAH*2412AM*+ furnace: 59TP6C040V14**10AHRI reference: 21564999015.208.00113001.90EPA 3997288 →
CSAH*2412AM*+ furnace: GG96VTAB30040A**AHRI reference: 21564999215.208.00113001.90EPA 3997289 →
CSAH*3012AM*+ furnace: 59TN6C040C14**10AHRI reference: 21565132115.208.00113002.05EPA 3997505 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →