Carrier / AIR-SOURCE HEAT PUMP

GH8TAN524**AA*

2-STAGE 18 SEER HP · source records, page 21

580 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for GH8TAN524**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 580 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5580 / 580
EER2 · BTU/Wh11.5–14580 / 580
HSPF2 · BTU/Wh7.8–8.5580 / 580
Cooling capacity · BTU/h22,200–25,000580 / 580
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400580 / 580
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000580 / 580
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500580 / 580
COP at 5°F / −15°C1.9–2.24580 / 580
Equipment / loop typeHP - Split System580 / 580
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)580 / 580
Compressor stagingTwo-stage580 / 580
Connected capabilityNo580 / 580

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**2417AM*+ furnace: 59TP7A080V17**16AHRI reference: 21572039216.508.00110002.04EPA 3980200 →
CAA**3017AM*+ furnace: 58CU*B060C17**16AHRI reference: 21572051616.507.80109002.06EPA 3980891 →
CAA**3017AM*+ furnace: 59TN7A060C17**16AHRI reference: 21572053016.508.10111002.05EPA 3980895 →
CAA**3017AM*+ furnace: 59TP7A060V17**16AHRI reference: 21572055816.508.10110002.10EPA 3980925 →
CAA**3617AM*+ furnace: 59TN7A060C17**16AHRI reference: 21572062216.508.00110002.06EPA 3980986 →
CAA**2517AM*+ furnace: 59TN7A040C14**10AHRI reference: 21799187616.508.00113002.06EPA 4566251 →
CAA**2517AM*+ furnace: 59TP7A040V14**10AHRI reference: 21799168916.508.00113002.06EPA 4566292 →
CAA**2517AM*+ furnace: GG97VTAA30040A**AHRI reference: 21799169016.508.00113002.06EPA 4566293 →
CAA**3717AM*+ furnace: 59TP7A040V14**10AHRI reference: 21799176916.508.00114002.04EPA 4566346 →
CAA**3717AM*+ furnace: GG97VTAA30040A**AHRI reference: 21799177016.508.00114002.04EPA 4566347 →
CAA**2414AM*+ furnace: 59TP7A060V14**12AHRI reference: 21799134416.508.00111002.04EPA 4566426 →
CAA**3617AM*+ furnace: 59TP7A040V17**12AHRI reference: 21799155216.508.00111002.02EPA 4566442 →
CAA**3717AM*+ furnace: 59TP7A040V17**12AHRI reference: 21799156816.508.00113002.04EPA 4566458 →
CAA**3014AM*+ furnace: 59TP7A060V14**12AHRI reference: 21799139216.508.00109002.04EPA 4566498 →
CAA**3017AM*+ furnace: 59TP7A060V14**12AHRI reference: 21799140816.508.00111002.02EPA 4566515 →
CAA**2517AM*+ furnace: 59TP7A040V17**12AHRI reference: 21799152016.508.00113002.08EPA 4566550 →
CAA**3617AM*+ furnace: 59TP7A060V14**12AHRI reference: 21799142416.508.00111002.04EPA 4566563 →
F55AA*B24L*AHRI reference: 21646425716.008.10110002.08EPA 3847169 →
CAA**2414AM*+ furnace: 59SP6B040V14**10AHRI reference: 21564342316.008.10112002.02EPA 3957006 →
CAA**2417AM*+ furnace: 59SP6B040V17**12AHRI reference: 21564396716.008.10113002.00EPA 3957497 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →