Carrier / AIR-SOURCE HEAT PUMP

GH8TAN524**AA*

2-STAGE 18 SEER HP · source records, page 19

580 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for GH8TAN524**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 580 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5580 / 580
EER2 · BTU/Wh11.5–14580 / 580
HSPF2 · BTU/Wh7.8–8.5580 / 580
Cooling capacity · BTU/h22,200–25,000580 / 580
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400580 / 580
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000580 / 580
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500580 / 580
COP at 5°F / −15°C1.9–2.24580 / 580
Equipment / loop typeHP - Split System580 / 580
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)580 / 580
Compressor stagingTwo-stage580 / 580
Connected capabilityNo580 / 580

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CSAH*3612AM*+ furnace: 58TP*B045V14**12AHRI reference: 21565218816.507.80109001.96EPA 3964096 →
CSAH*3612AM*+ furnace: 58TP*B070V14**12AHRI reference: 21565221416.507.80109001.96EPA 3964110 →
CSAH*3612AM*+ furnace: 58TP*B070V17**16AHRI reference: 21565222916.507.80110001.96EPA 3964120 →
CSAH*3612AM*+ furnace: 58TP*B090V17**16AHRI reference: 21565225216.507.80110001.96EPA 3964141 →
CSAH*3612AM*+ furnace: 58TP*B090V21**20AHRI reference: 21565226716.507.80110002.08EPA 3964142 →
CSAH*3612AM*+ furnace: 58TP*B135V24**22AHRI reference: 21565231816.508.00110002.06EPA 3964182 →
CSAH*3012AM*+ furnace: 59TP6C080V21**20AHRI reference: 21565158516.508.00111002.06EPA 3964236 →
CSAH*3012AM*+ furnace: GG96VTAB60100C**AHRI reference: 21565161116.507.80110002.08EPA 3964251 →
CSAH*3012AM*+ furnace: 59TP6C100V21**20AHRI reference: 21565161016.507.80110002.08EPA 3964257 →
CSAH*3012AM*+ furnace: 59TP6C100V21**22AHRI reference: 21565163816.508.10111002.08EPA 3964267 →
CSAH*3012AM*+ furnace: GG96VTAB66120D**AHRI reference: 21565166116.508.00111002.06EPA 3964283 →
CSAH*3012AM*+ furnace: 59TP6C120V24**22AHRI reference: 21565165916.508.00111002.06EPA 3964289 →
CSAH*3012AM*+ furnace: OVMAAB036098AHRI reference: 21565170616.508.00115002.05EPA 3964312 →
CSAH*3612AM*+ furnace: 59CU5B100C21**22AHRI reference: 21565237116.507.80110002.08EPA 3964332 →
CSAH*3612AM*+ furnace: 59MN7C080C21**20AHRI reference: 21565245416.507.80110002.08EPA 3964342 →
CSAH*3612AM*+ furnace: 59MN7C100C21**22AHRI reference: 21565247616.507.80109002.08EPA 3964368 →
CSAH*3612AM*+ furnace: 59SP6B060V17**16AHRI reference: 21565257516.507.80110001.96EPA 3964372 →
CSAH*3612AM*+ furnace: 59SP6B080V21**20AHRI reference: 21565261316.507.80109001.96EPA 3964388 →
CSAH*3612AM*+ furnace: 59SP6B100V21**20AHRI reference: 21565263216.508.00110002.08EPA 3964400 →
CSAH*3612AM*+ furnace: 58SP*B045V14**12AHRI reference: 21565177216.507.80109001.96EPA 3964495 →