Carrier / AIR-SOURCE HEAT PUMP

GH8TAN524**AA*

2-STAGE 18 SEER HP · source records, page 15

580 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for GH8TAN524**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 580 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5580 / 580
EER2 · BTU/Wh11.5–14580 / 580
HSPF2 · BTU/Wh7.8–8.5580 / 580
Cooling capacity · BTU/h22,200–25,000580 / 580
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400580 / 580
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000580 / 580
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500580 / 580
COP at 5°F / −15°C1.9–2.24580 / 580
Equipment / loop typeHP - Split System580 / 580
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)580 / 580
Compressor stagingTwo-stage580 / 580
Connected capabilityNo580 / 580

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**2417AM*+ furnace: 58TN*B070C17**16AHRI reference: 21564376416.508.10110002.04EPA 3957354 →
CAA**2417AM*+ furnace: 58TN*B090C17**16AHRI reference: 21564378416.508.10110002.04EPA 3957371 →
CAA**2417AM*+ furnace: 58TP*B045V14**12AHRI reference: 21564380516.508.10110002.04EPA 3957386 →
CAA**2417AM*+ furnace: 58TP*B070V17**16AHRI reference: 21564384516.508.10110002.04EPA 3957415 →
CAA**2417AM*+ furnace: 59CU5B060C17**16AHRI reference: 21564388416.508.00111002.05EPA 3957438 →
CAA**2417AM*+ furnace: 59MN7C060C17**14AHRI reference: 21564390516.508.10111002.04EPA 3957459 →
CAA**2417AM*+ furnace: 59MN7C080C17**14AHRI reference: 21564392616.508.10111002.04EPA 3957470 →
CAA**2417AM*+ furnace: 59SP6B060V17**16AHRI reference: 21564400916.508.10110002.04EPA 3957524 →
CAA**2417AM*+ furnace: 59SP6B080V17**16AHRI reference: 21564402816.508.10110002.04EPA 3957531 →
CAA**2417AM*+ furnace: 59SU5B040M17**12AHRI reference: 21564404816.507.80111002.02EPA 3957545 →
CAA**2417AM*+ furnace: 59SU5B060M17**16AHRI reference: 21564407716.507.80110002.04EPA 3957567 →
CAA**2417AM*+ furnace: 59TN6C060C17**14AHRI reference: 21564412516.508.10111002.04EPA 3957598 →
CAA**2417AM*+ furnace: 59TN6C080C17**14AHRI reference: 21564414616.508.10111002.04EPA 3957615 →
CAA**2417AM*+ furnace: GG96VTAB48060B**AHRI reference: 21564424316.508.10110002.04EPA 3957682 →
CAA**2417AM*+ furnace: 59TP6C060V17**16AHRI reference: 21564424216.508.10110002.04EPA 3957683 →
CAA**2417AM*+ furnace: GG96VTAB48080B**AHRI reference: 21564427316.508.10110002.04EPA 3957705 →
CAA**2417AM*+ furnace: 59TP6C080V17**16AHRI reference: 21564427216.508.10110002.04EPA 3957706 →
CAA**2417AM*+ furnace: OVMAAB042112AHRI reference: 21564434116.508.10112002.00EPA 3957753 →
CAA**2517AM*+ furnace: 59SP6B040V14**10AHRI reference: 21564474316.508.10113002.06EPA 3958018 →
CAA**2517AM*+ furnace: 59SP6B040V17**12AHRI reference: 21564476216.508.10113002.08EPA 3958027 →