Carrier / AIR-SOURCE HEAT PUMP

GH8TAN524**AA*

2-STAGE 18 SEER HP · source records, page 11

580 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for GH8TAN524**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 580 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5580 / 580
EER2 · BTU/Wh11.5–14580 / 580
HSPF2 · BTU/Wh7.8–8.5580 / 580
Cooling capacity · BTU/h22,200–25,000580 / 580
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400580 / 580
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000580 / 580
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500580 / 580
COP at 5°F / −15°C1.9–2.24580 / 580
Equipment / loop typeHP - Split System580 / 580
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)580 / 580
Compressor stagingTwo-stage580 / 580
Connected capabilityNo580 / 580

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**3017AM*+ furnace: 59SP6B080V17**16AHRI reference: 21564583317.008.10110002.06EPA 3958832 →
CAA**3017AM*+ furnace: OVMAAB042112AHRI reference: 21564614917.008.10112002.02EPA 3958897 →
CAA**3617AM*+ furnace: 58CU*A040C17**12AHRI reference: 21564616917.007.80110002.06EPA 3958917 →
CAA**3017AM*+ furnace: 59SU5B060M17**16AHRI reference: 21564588017.007.80110002.04EPA 3958940 →
CAA**3017AM*+ furnace: 59TN6C060C17**14AHRI reference: 21564593017.008.10110002.06EPA 3958959 →
CAA**3017AM*+ furnace: 59TN6C080C17**14AHRI reference: 21564595117.008.10110002.06EPA 3958963 →
CAA**3617AM*+ furnace: 58SP*B090V17**16AHRI reference: 21564624917.008.10109002.08EPA 3959041 →
CAA**3617AM*+ furnace: 58TN*B045C17**12AHRI reference: 21564632317.008.10110002.06EPA 3959087 →
CAA**3617AM*+ furnace: 58TN*B070C14**12AHRI reference: 21564634317.008.10109002.08EPA 3959108 →
CAA**3617AM*+ furnace: 58TN*B070C17**16AHRI reference: 21564636317.008.10110002.06EPA 3959112 →
CAA**3617AM*+ furnace: 58TN*B090C17**16AHRI reference: 21564638417.008.10110002.06EPA 3959127 →
CAA**3617AM*+ furnace: 58TP*B070V17**16AHRI reference: 21564645017.008.10109002.06EPA 3959176 →
CAA**3617AM*+ furnace: 59SP6B060V17**16AHRI reference: 21564660717.008.10110002.06EPA 3959179 →
CAA**3617AM*+ furnace: 58TP*B090V17**16AHRI reference: 21564647317.008.10109002.08EPA 3959194 →
CAA**3617AM*+ furnace: 59CU5B060C17**16AHRI reference: 21564648717.007.80109002.06EPA 3959202 →
CAA**3617AM*+ furnace: 59SP6B080V17**16AHRI reference: 21564662617.008.10109002.06EPA 3959225 →
CAA**3617AM*+ furnace: 59MN7C060C17**14AHRI reference: 21564650817.008.10110002.06EPA 3959226 →
CAA**3617AM*+ furnace: 59MN7C080C17**14AHRI reference: 21564652917.008.10109002.06EPA 3959237 →
CAA**3617AM*+ furnace: 59SU5B060M17**16AHRI reference: 21564667217.007.80109002.06EPA 3959424 →
CAA**3617AM*+ furnace: 59TN6C060C17**14AHRI reference: 21564672017.008.10110002.06EPA 3959458 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →