GH5SAN536**AA*
15 SEER2 HP
30 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for GH5SAN536**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 30 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 30 / 30 |
| EER2 · BTU/Wh | 11.7–13 | 30 / 30 |
| HSPF2 · BTU/Wh | 7.8–8 | 30 / 30 |
| Cooling capacity · BTU/h | 33,800–36,800 | 30 / 30 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,200–36,400 | 30 / 30 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 21,000–22,800 | 30 / 30 |
| Heating capacity at 5°F / −15°C · BTU/h | 16,100–18,100 | 30 / 30 |
| COP at 5°F / −15°C | 2–2.22 | 30 / 30 |
| Equipment / loop type | HP - Split System | 30 / 30 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 30 / 30 |
| Compressor staging | Single stage | 30 / 30 |
| Connected capability | No | 30 / 30 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FEVA0048**+NAVA54801CKAHRI reference: 217051633 | 16.00 | 8.00 | 17400 | 2.18 | EPA 4497007 → |
FT5AN(B,X)C48L*AHRI reference: 214179924 | 15.50 | 7.80 | 16700 | 2.18 | EPA 3404447 → |
FG5ANXC48L*AHRI reference: 214179925 | 15.50 | 7.80 | 16700 | 2.18 | EPA 3404448 → |
FJ5AN*C48L*AHRI reference: 214180170 | 15.50 | 7.80 | 17400 | 2.18 | EPA 3404786 → |
FEVB0048**+NAVA54801CKAHRI reference: 214277592 | 15.50 | 7.80 | 17400 | 2.22 | EPA 3415682 → |
FMA5X36**AL*AHRI reference: 214424285 | 15.50 | 7.80 | 17000 | 2.00 | EPA 3425175 → |
F55AA*C48L*AHRI reference: 216463997 | 15.50 | 7.80 | 17400 | 2.18 | EPA 3846919 → |
CAA**4821AM*+ furnace: 58SU*B060M17**16AHRI reference: 214141627 | 15.20 | 7.80 | 17600 | 2.18 | EPA 3400311 → |
CAA**4821AM*+ furnace: 59SU5B100M21**22AHRI reference: 214142630 | 15.20 | 7.80 | 17600 | 2.18 | EPA 3400435 → |
CAA**4821AM*+ furnace: 58TN*B110C21**20AHRI reference: 214141831 | 15.20 | 7.80 | 17500 | 2.18 | EPA 3400467 → |
CAA**4821AM*+ furnace: 58TP*B090V21**20AHRI reference: 214141940 | 15.20 | 7.80 | 17500 | 2.18 | EPA 3400606 → |
CAA**4821AM*+ furnace: 59TP6C100V21**22AHRI reference: 214142856 | 15.20 | 7.80 | 17500 | 2.20 | EPA 3400661 → |
CAA**4821AM*+ furnace: 58S(B,C)*B090M21**20AHRI reference: 214141335 | 15.20 | 7.80 | 17500 | 2.18 | EPA 3400761 → |
CAA**4321AM*+ furnace: 59SC2E100M21**20AHRI reference: 214140508 | 15.20 | 7.80 | 17900 | 2.20 | EPA 3400783 → |
CAA**4821AM*+ furnace: 58S(B,C)*B110M21**20AHRI reference: 214141365 | 15.20 | 7.80 | 17600 | 2.20 | EPA 3400834 → |
CAA**4821AM*+ furnace: 59SC2E100M21**20AHRI reference: 214142254 | 15.20 | 7.80 | 17600 | 2.18 | EPA 3400865 → |
CAA**4821AM*+ furnace: 58SP*B090V21**20AHRI reference: 214141449 | 15.20 | 7.80 | 17500 | 2.18 | EPA 3400915 → |
CVAMA4421XMA*+ furnace: 58SU*A040E17**12AHRI reference: 214143043 | 15.20 | 7.80 | 18100 | 2.14 | EPA 3401007 → |
CAA**4321AM*+ furnace: 58CU*A100C21**20AHRI reference: 214139780 | 15.20 | 7.80 | 17600 | 2.18 | EPA 3401038 → |
CAA**3721AM*+ furnace: 58CU*A060C17**16AHRI reference: 214138081 | 15.20 | 7.80 | 17100 | 2.16 | EPA 3401041 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →