Carrier / AIR-SOURCE HEAT PUMP

GH5SAN524**AA*

15 SEER2 HP · source records, page 10

206 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,400BTU/h

Each efficiency range summarizes published EPA records for GH5SAN524**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 206 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5206 / 206
EER2 · BTU/Wh11.7–13206 / 206
HSPF2 · BTU/Wh7.8–8.5206 / 206
Cooling capacity · BTU/h22,200–24,400206 / 206
Heating capacity at 47°F / 8.3°C · BTU/h21,600–24,000206 / 206
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,200206 / 206
Heating capacity at 5°F / −15°C · BTU/h10,800–11,900206 / 206
COP at 5°F / −15°C1.96–2.26206 / 206
Equipment / loop typeHP - Split System206 / 206
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)206 / 206
Compressor stagingSingle stage206 / 206
Connected capabilityNo206 / 206

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**3721AM*+ furnace: GG96VTAB48060B**AHRI reference: 21420315715.207.80118002.12EPA 3407439
CAA**3721AM*+ furnace: 59TP6C080V17**16AHRI reference: 21420318715.207.80116002.12EPA 3407469
CAA**3721AM*+ furnace: GG96VTAB48080B**AHRI reference: 21420318815.207.80116002.12EPA 3407470
CAA**3717AM*+ furnace: 59SC2E060M14**12AHRI reference: 21420065815.207.80113002.08EPA 3407562
CAA**3717AM*+ furnace: 59SC6A060M17**16AHRI reference: 21420078215.207.80114002.08EPA 3407614
CAA**3717AM*+ furnace: 58SP*B045V14**12AHRI reference: 21419993215.207.80112002.08EPA 3407851
CAA**3721AM*+ furnace: 59SC6A060M17**16AHRI reference: 21420247115.207.80117002.12EPA 3407942
CAA**3721AM*+ furnace: 59SC6A080M17**16AHRI reference: 21420250315.207.80116002.12EPA 3407974
CAA**3717AM*+ furnace: 58SP*B070V14**12AHRI reference: 21419995715.207.80112002.08EPA 3408006
CAA**3717AM*+ furnace: 58SP*B070V17**16AHRI reference: 21419998215.207.80113002.08EPA 3408031
CAA**3721AM*+ furnace: 58SP*B070V17**16AHRI reference: 21420165515.207.80115002.14EPA 3408180
CAA**3717AM*+ furnace: 59SP6B060V17**16AHRI reference: 21420090215.207.80114002.08EPA 3408318
CAA**3717AM*+ furnace: 59SP6B080V17**16AHRI reference: 21420092715.207.80114002.08EPA 3408345
CAA**3721AM*+ furnace: 58SP*B090V17**16AHRI reference: 21420168115.207.80116002.14EPA 3408379
CAA**3721AM*+ furnace: 59SP6B080V17**16AHRI reference: 21420272315.207.80116002.12EPA 3408693
CAA**3721AM*+ furnace: 59SP6B060V17**16AHRI reference: 21420269815.207.80118002.12EPA 3408705
CAA**2517AM*+ furnace: 58CU*A040C17**12AHRI reference: 21421028115.207.80112002.12EPA 3409635
CAA**2517AM*+ furnace: 58S(B,C)*B070M14**12AHRI reference: 21421034215.207.80113002.12EPA 3409734
CAA**2517AM*+ furnace: 58SP*B070V14**12AHRI reference: 21421043615.207.80113002.12EPA 3410089
CAA**2517AM*+ furnace: 58SU*A040E17**12AHRI reference: 21421046115.207.80110002.08EPA 3410354

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →