Carrier / AIR-SOURCE HEAT PUMP

GH5SAN524**AA*

15 SEER2 HP

206 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,400BTU/h

Each efficiency range summarizes published EPA records for GH5SAN524**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 206 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5206 / 206
EER2 · BTU/Wh11.7–13206 / 206
HSPF2 · BTU/Wh7.8–8.5206 / 206
Cooling capacity · BTU/h22,200–24,400206 / 206
Heating capacity at 47°F / 8.3°C · BTU/h21,600–24,000206 / 206
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,200206 / 206
Heating capacity at 5°F / −15°C · BTU/h10,800–11,900206 / 206
COP at 5°F / −15°C1.96–2.26206 / 206
Equipment / loop typeHP - Split System206 / 206
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)206 / 206
Compressor stagingSingle stage206 / 206
Connected capabilityNo206 / 206

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FMA5X30**AL*AHRI reference: 21442406916.508.50116002.26EPA 3425351
CVAVA3117XMA*+ furnace: 58SP*B090V17**16AHRI reference: 21420505716.007.80113001.98EPA 3408529
CVAVA3117XMA*+ furnace: 58TP*B090V17**16AHRI reference: 21420520316.007.80113001.98EPA 3408930
CVAMA3217XMA*+ furnace: 58SU*B060M17**16AHRI reference: 21421273316.007.80113002.00EPA 3408982
CVAVA3817XMA*+ furnace: 58TP*B070V17**16AHRI reference: 21421435316.007.80114002.00EPA 3409009
CVAVA3817XMA*+ furnace: 58TP*B090V17**16AHRI reference: 21421438116.007.80114002.00EPA 3409036
CVAVA3721XMA*+ furnace: 58S(B,C)*B090M21**16AHRI reference: 21421339016.007.80112001.98EPA 3409064
CAA**3721AM*+ furnace: 58CU*A080C21**20AHRI reference: 21421090716.007.80113002.14EPA 3409112
CVAMA3217XMA*+ furnace: 58SP*B090V17**16AHRI reference: 21421264416.007.80114001.98EPA 3409250
CAA**3721AM*+ furnace: 59SU5B100M21**20AHRI reference: 21421196516.007.80115002.14EPA 3409571
CVAVA3817XMA*+ furnace: 59SC2E060M17**14AHRI reference: 21421448016.007.80114002.00EPA 3409638
CAA**3721AM*+ furnace: 59TN6B100C21**22AHRI reference: 21421202016.007.80112002.12EPA 3409870
CVAMA3217XMA*+ furnace: 58TP*B090V17**16AHRI reference: 21421288916.007.80114001.98EPA 3409891
CAA**3721AM*+ furnace: 59TN6C080C21**20AHRI reference: 21421204716.007.80114001.96EPA 3410104
CAA**3721AM*+ furnace: 59TN6C100C21**22AHRI reference: 21421207416.007.80115002.14EPA 3410131
CVAMA3217XMA*+ furnace: 59SC2E080M17**16AHRI reference: 21421299316.007.80112001.98EPA 3410181
CAA**2517AM*+ furnace: 58SU*B040M17**12AHRI reference: 21421052516.007.80113002.12EPA 3410286
CAA**2517AM*+ furnace: 58SU*B060M17**16AHRI reference: 21421055716.007.80112002.12EPA 3410530
CVAVA3817XMA*+ furnace: 58S(B,C)*B070M17**12AHRI reference: 21421397016.007.80114002.00EPA 3410631
CAA**3721AM*+ furnace: 58TN*B090C21**20AHRI reference: 21421142716.007.80115002.14EPA 3410673

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →