GH5SAN519**AA*
15 SEER2 HP · source records, page 2
84 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for GH5SAN519**AA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 84 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 84 / 84 |
| EER2 · BTU/Wh | 12.5–13 | 84 / 84 |
| HSPF2 · BTU/Wh | 7.8–8 | 84 / 84 |
| Cooling capacity · BTU/h | 17,700–19,300 | 84 / 84 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 18,400–19,500 | 84 / 84 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 10,300–11,000 | 84 / 84 |
| Heating capacity at 5°F / −15°C · BTU/h | 7,900–8,500 | 84 / 84 |
| COP at 5°F / −15°C | 1.9–2 | 84 / 84 |
| Equipment / loop type | HP - Split System | 84 / 84 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 84 / 84 |
| Compressor staging | Single stage | 84 / 84 |
| Connected capability | No | 84 / 84 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CAA**2517AM*+ furnace: 58TN*B070C14**12AHRI reference: 217705225 | 16.00 | 8.00 | 8400 | 2.00 | EPA 4508436 → |
CAA**2517AM*+ furnace: 59MN7C080C17**14AHRI reference: 217705397 | 16.00 | 8.00 | 8400 | 2.00 | EPA 4508519 → |
CAA**2517AM*+ furnace: 58TP*B045V14**12AHRI reference: 217705291 | 16.00 | 8.00 | 8400 | 2.00 | EPA 4508557 → |
CAA**2517AM*+ furnace: 58TP*B070V14**12AHRI reference: 217705316 | 16.00 | 8.00 | 8400 | 2.00 | EPA 4508581 → |
CAA**2517AM*+ furnace: 58TP*B070V17**16AHRI reference: 217705323 | 16.00 | 8.00 | 8400 | 2.00 | EPA 4508589 → |
CAA**1917AM*+ furnace: 59TN6C080C17**14AHRI reference: 217702870 | 16.00 | 8.00 | 8300 | 2.00 | EPA 4508634 → |
CAA**2517AM*+ furnace: 58TP*B090V17**16AHRI reference: 217705346 | 16.00 | 8.00 | 8400 | 2.00 | EPA 4508657 → |
CAA**2517AM*+ furnace: 59SC2E080M17**16AHRI reference: 217705496 | 16.00 | 8.00 | 8300 | 2.00 | EPA 4508743 → |
CAA**2517AM*+ furnace: 59SC2E060M14**12AHRI reference: 217705446 | 16.00 | 8.00 | 8300 | 2.00 | EPA 4508794 → |
CAA**2517AM*+ furnace: 59SC2E060M17**14AHRI reference: 217705469 | 16.00 | 8.00 | 8400 | 2.00 | EPA 4508817 → |
CAA**1917AM*+ furnace: 58CU*B040C17**12AHRI reference: 217702213 | 16.00 | 7.80 | 8300 | 1.95 | EPA 4508884 → |
CAA**1917AM*+ furnace: 58CU*B060C17**16AHRI reference: 217702235 | 16.00 | 7.80 | 8300 | 1.95 | EPA 4508907 → |
FJ5AN*B24L*AHRI reference: 217686894 | 15.50 | 7.80 | 8000 | 1.90 | EPA 4505863 → |
F55AA*B24L*AHRI reference: 217686895 | 15.50 | 7.80 | 8000 | 1.90 | EPA 4505869 → |
FMA5X18**AL*AHRI reference: 217687180 | 15.50 | 7.80 | 7900 | 2.00 | EPA 4506299 → |
FMA5X24**AL*AHRI reference: 217687212 | 15.50 | 7.80 | 7900 | 2.00 | EPA 4506331 → |
FT5ANXB24L*AHRI reference: 217687246 | 15.50 | 7.80 | 8100 | 1.95 | EPA 4506448 → |
FG5ANXB24L*AHRI reference: 217687247 | 15.50 | 7.80 | 8100 | 1.95 | EPA 4506449 → |
FM(C,U)5Z18**AL*AHRI reference: 217687020 | 15.50 | 7.80 | 8100 | 2.00 | EPA 4506528 → |
FM(C,U)5Z24**AL*AHRI reference: 217687052 | 15.50 | 7.80 | 8100 | 2.00 | EPA 4506558 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →