37MURAQ24AA3+KSAIC0701230
Crossover Heat Pump · Crossover heat pump · source records, page 5
143 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 37MURAQ24AA3+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 143 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 143 / 143 |
| EER2 · BTU/Wh | 9.5–10 | 143 / 143 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 143 / 143 |
| Cooling capacity · BTU/h | 23,200–25,200 | 143 / 143 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 24,000–26,000 | 143 / 143 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 18,300–19,500 | 143 / 143 |
| Heating capacity at 5°F / −15°C · BTU/h | 19,000–20,000 | 143 / 143 |
| COP at 5°F / −15°C | 1.88–2.14 | 143 / 143 |
| Equipment / loop type | HP - Split System | 143 / 143 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 143 / 143 |
| Compressor staging | Continuously variable | 143 / 143 |
| Connected capability | No | 143 / 143 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FJ5AN*B30L*Cold climate designationAHRI reference: 218475084 | 15.20 | 9.00 | 19400 | 2.04 | EPA 4625894 → |
FEVB0024**+NAVA53601CKCold climate designationAHRI reference: 218475081 | 15.20 | 9.00 | 19400 | 2.06 | EPA 4625897 → |
CAA**3721AM*+ furnace: OVMAAB042112Cold climate designationAHRI reference: 218475077 | 15.20 | 9.00 | 19300 | 2.06 | EPA 4625899 → |
CAA**3617AM*+ furnace: 59TP7A080V17**16Cold climate designationAHRI reference: 218475060 | 15.20 | 8.50 | 19400 | 1.90 | EPA 4625903 → |
CAA**3617AM*+ furnace: 59TP7A060V17**16Cold climate designationAHRI reference: 218475055 | 15.20 | 8.50 | 19400 | 1.92 | EPA 4625906 → |
CAA**3617AM*+ furnace: 59TP6C080V17**16Cold climate designationAHRI reference: 218475043 | 15.20 | 8.50 | 19400 | 1.90 | EPA 4625910 → |
CAA**3617AM*+ furnace: 59TP6C060V17**16Cold climate designationAHRI reference: 218475038 | 15.20 | 8.50 | 19400 | 1.92 | EPA 4625913 → |
CAA**3617AM*+ furnace: 59TP6C060V14**12Cold climate designationAHRI reference: 218475034 | 15.20 | 8.50 | 19400 | 1.90 | EPA 4625914 → |
CAA**3717AM*+ furnace: 59TP6C040V17**12Cold climate designationAHRI reference: 218475030 | 15.20 | 8.50 | 19300 | 1.96 | EPA 4625915 → |
CSAH*3012AM*+ furnace: 59SU5B080M21**20Cold climate designationAHRI reference: 218475024 | 15.20 | 8.50 | 19600 | 1.90 | EPA 4625916 → |
CSAH*3612AM*+ furnace: 59SU5B100M21**20Cold climate designationAHRI reference: 218475019 | 15.20 | 8.50 | 19300 | 1.92 | EPA 4625919 → |
CSAH*3612AM*+ furnace: 59SC2E080M17**16Cold climate designationAHRI reference: 218475013 | 15.20 | 8.50 | 19200 | 1.94 | EPA 4625923 → |
CAA**3017AM*+ furnace: 59SU5B060M17**16Cold climate designationAHRI reference: 218475012 | 15.20 | 8.50 | 19400 | 1.90 | EPA 4625924 → |
CSAH*3612AM*+ furnace: 59SP6B100V21**20Cold climate designationAHRI reference: 218475004 | 15.20 | 8.50 | 19400 | 1.92 | EPA 4625927 → |
CAA**3617AM*+ furnace: 59SP6B080V17**16Cold climate designationAHRI reference: 218474997 | 15.20 | 8.50 | 19400 | 1.90 | EPA 4625930 → |
CAA**3617AM*+ furnace: 59SP6B060V17**16Cold climate designationAHRI reference: 218474992 | 15.20 | 8.50 | 19400 | 1.92 | EPA 4625933 → |
CAA**3617AM*+ furnace: 59SP6B060V14**12Cold climate designationAHRI reference: 218474988 | 15.20 | 8.50 | 19400 | 1.90 | EPA 4625934 → |
CAA**3717AM*+ furnace: 59SP6B040V17**12Cold climate designationAHRI reference: 218474984 | 15.20 | 8.50 | 19300 | 1.96 | EPA 4625935 → |
CAA**3617AM*+ furnace: 59SC6A080M17**16Cold climate designationAHRI reference: 218474966 | 15.20 | 8.50 | 19400 | 1.92 | EPA 4625939 → |
CSAH*3612AM*+ furnace: 59SC2E100M21**20Cold climate designationAHRI reference: 218474945 | 15.20 | 8.50 | 19300 | 1.94 | EPA 4625941 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →