37MUHAQ30AA3+KSAIC0701230
Crossover Heat Pump · source records, page 2
371 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 37MUHAQ30AA3+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 371 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 371 / 371 |
| EER2 · BTU/Wh | 9.5–10.5 | 371 / 371 |
| HSPF2 · BTU/Wh | 8.1–9 | 371 / 371 |
| Cooling capacity · BTU/h | 28,600–31,200 | 371 / 371 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 35,800–37,400 | 371 / 371 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 20,800–21,600 | 371 / 371 |
| Heating capacity at 5°F / −15°C · BTU/h | 32,000–33,400 | 371 / 371 |
| COP at 5°F / −15°C | 1.75–2 | 371 / 371 |
| Equipment / loop type | HP - Split System | 371 / 371 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 371 / 371 |
| Compressor staging | Continuously variable | 371 / 371 |
| Connected capability | No | 371 / 371 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CAA**3721AM*+ furnace: 58SP*B090V17**16Cold climate designationAHRI reference: 218474143 | 16.50 | 9.00 | 32200 | 1.96 | EPA 4625311 → |
CAA**4221AM*+ furnace: 59TP7A100V21**20Cold climate designationAHRI reference: 218474128 | 16.50 | 8.50 | 32800 | 1.80 | EPA 4625324 → |
CAA**4221AM*+ furnace: 59TP6C100V21**20Cold climate designationAHRI reference: 218474123 | 16.50 | 8.50 | 32800 | 1.80 | EPA 4625329 → |
CAA**4221AM*+ furnace: 59SP6B100V21**20Cold climate designationAHRI reference: 218474113 | 16.50 | 8.50 | 32800 | 1.80 | EPA 4625338 → |
CAA**4221AM*+ furnace: 58SU*B080M21**20Cold climate designationAHRI reference: 218474093 | 16.50 | 8.50 | 33000 | 1.80 | EPA 4625357 → |
CAA**4221AM*+ furnace: 58SU*B060M17**16Cold climate designationAHRI reference: 218474092 | 16.50 | 8.50 | 32800 | 1.80 | EPA 4625358 → |
CAA**4321AM*+ furnace: 59TP7A100V21**22Cold climate designationAHRI reference: 218474074 | 16.50 | 9.00 | 32200 | 1.96 | EPA 4625374 → |
CAA**4321AM*+ furnace: 59TP7A100V21**20Cold climate designationAHRI reference: 218474073 | 16.50 | 9.00 | 32200 | 1.98 | EPA 4625375 → |
CAA**4321AM*+ furnace: 59TP7A080V21**20Cold climate designationAHRI reference: 218474072 | 16.50 | 9.00 | 32200 | 1.96 | EPA 4625376 → |
CAA**4321AM*+ furnace: 59TP6C100V21**22Cold climate designationAHRI reference: 218474069 | 16.50 | 9.00 | 32200 | 1.96 | EPA 4625379 → |
CAA**4321AM*+ furnace: 59TP6C100V21**20Cold climate designationAHRI reference: 218474068 | 16.50 | 9.00 | 32200 | 1.98 | EPA 4625380 → |
CAA**4321AM*+ furnace: 59TP6C080V21**20Cold climate designationAHRI reference: 218474067 | 16.50 | 9.00 | 32200 | 1.96 | EPA 4625381 → |
CAA**4321AM*+ furnace: 59SU5B100M21**22Cold climate designationAHRI reference: 218474063 | 16.50 | 9.00 | 32200 | 1.98 | EPA 4625385 → |
CAA**4321AM*+ furnace: 59SU5B100M21**20Cold climate designationAHRI reference: 218474062 | 16.50 | 9.00 | 32200 | 1.98 | EPA 4625386 → |
CAA**4321AM*+ furnace: 59SP6B100V21**20Cold climate designationAHRI reference: 218474058 | 16.50 | 9.00 | 32200 | 1.98 | EPA 4625390 → |
CAA**4321AM*+ furnace: 59SP6B080V21**20Cold climate designationAHRI reference: 218474057 | 16.50 | 9.00 | 32200 | 1.96 | EPA 4625391 → |
CAA**4321AM*+ furnace: 58TP*B110V21**22Cold climate designationAHRI reference: 218474043 | 16.50 | 9.00 | 32200 | 1.96 | EPA 4625405 → |
CAA**4321AM*+ furnace: 58TP*B090V17**16Cold climate designationAHRI reference: 218474041 | 16.50 | 9.00 | 32200 | 1.96 | EPA 4625407 → |
CAA**4321AM*+ furnace: 58TP*B070V17**16Cold climate designationAHRI reference: 218474040 | 16.50 | 9.00 | 32200 | 1.96 | EPA 4625408 → |
CAA**4321AM*+ furnace: 58SU*B060M17**16Cold climate designationAHRI reference: 218474037 | 16.50 | 9.00 | 32200 | 1.96 | EPA 4625411 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →