Heating performance & equipment details
Ranges include the 557 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 557 / 557 |
| EER2 · BTU/Wh | 10–11 | 557 / 557 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 557 / 557 |
| Cooling capacity · BTU/h | 22,600–25,000 | 557 / 557 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,200–25,800 | 557 / 557 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 16,800–18,700 | 557 / 557 |
| Heating capacity at 5°F / −15°C · BTU/h | 18,700–20,600 | 557 / 557 |
| COP at 5°F / −15°C | 1.85–2.06 | 557 / 557 |
| Equipment / loop type | HP - Split System | 557 / 557 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 557 / 557 |
| Compressor staging | Continuously variable | 557 / 557 |
| Connected capability | No | 557 / 557 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CAA**3717AM*+ furnace: 59TP7A080V17**16Cold climate designationAHRI reference: 218473604 | 17.00 | 8.50 | 19200 | 1.92 | EPA 4625729 → |
CAA**3717AM*+ furnace: 59TP7A060V17**16Cold climate designationAHRI reference: 218473603 | 17.00 | 8.50 | 19100 | 1.92 | EPA 4625730 → |
CAA**3717AM*+ furnace: 59TP6C080V17**16Cold climate designationAHRI reference: 218473602 | 17.00 | 8.50 | 19200 | 1.92 | EPA 4625731 → |
CAA**3717AM*+ furnace: 59TP6C060V17**16Cold climate designationAHRI reference: 218473601 | 17.00 | 8.50 | 19100 | 1.92 | EPA 4625732 → |
CAA**3717AM*+ furnace: 59SU5B060M17**16Cold climate designationAHRI reference: 218473597 | 17.00 | 8.50 | 19100 | 1.92 | EPA 4625736 → |
CAA**3717AM*+ furnace: 59SU5B040M17**12Cold climate designationAHRI reference: 218473596 | 17.00 | 8.50 | 19100 | 1.92 | EPA 4625737 → |
CAA**3717AM*+ furnace: 59SP6B080V17**16Cold climate designationAHRI reference: 218473595 | 17.00 | 8.50 | 19200 | 1.92 | EPA 4625738 → |
CAA**3717AM*+ furnace: 59SP6B060V17**16Cold climate designationAHRI reference: 218473594 | 17.00 | 8.50 | 19100 | 1.92 | EPA 4625739 → |
CAA**3717AM*+ furnace: 58TP*B090V17**16Cold climate designationAHRI reference: 218473590 | 17.00 | 8.50 | 19100 | 1.92 | EPA 4625743 → |
CAA**3717AM*+ furnace: 58TP*B070V17**16Cold climate designationAHRI reference: 218473589 | 17.00 | 8.50 | 19100 | 1.92 | EPA 4625744 → |
CAA**3717AM*+ furnace: 58SU*B040M17**12Cold climate designationAHRI reference: 218473585 | 17.00 | 8.50 | 19100 | 1.92 | EPA 4625748 → |
CAA**3717AM*+ furnace: 58SP*B090V17**16Cold climate designationAHRI reference: 218473584 | 17.00 | 8.50 | 19100 | 1.92 | EPA 4625749 → |
CAA**3617AM*+ furnace: 59TP7A080V17**16Cold climate designationAHRI reference: 218473577 | 17.00 | 8.50 | 19400 | 1.90 | EPA 4625756 → |
CAA**3617AM*+ furnace: 59TP6C080V17**16Cold climate designationAHRI reference: 218473575 | 17.00 | 8.50 | 19400 | 1.90 | EPA 4625758 → |
CAA**3617AM*+ furnace: 59SU5B060M17**16Cold climate designationAHRI reference: 218473570 | 17.00 | 8.50 | 19400 | 1.88 | EPA 4625763 → |
CAA**3617AM*+ furnace: 59SP6B080V17**16Cold climate designationAHRI reference: 218473568 | 17.00 | 8.50 | 19400 | 1.90 | EPA 4625765 → |
CAA**3617AM*+ furnace: 58TP*B090V17**16Cold climate designationAHRI reference: 218473563 | 17.00 | 8.50 | 19400 | 1.90 | EPA 4625770 → |
CAA**3617AM*+ furnace: 58TP*B070V17**16Cold climate designationAHRI reference: 218473562 | 17.00 | 8.50 | 19400 | 1.90 | EPA 4625771 → |
CAA**3617AM*+ furnace: 58TP*B045V14**12Cold climate designationAHRI reference: 218473560 | 17.00 | 8.50 | 19400 | 1.90 | EPA 4625773 → |
CAA**3617AM*+ furnace: 58SP*B090V17**16Cold climate designationAHRI reference: 218473557 | 17.00 | 8.50 | 19400 | 1.90 | EPA 4625776 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.