37MUHAQ24AA3+KSAIC0701230
Crossover Heat Pump · source records, page 16
557 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 37MUHAQ24AA3+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 557 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 557 / 557 |
| EER2 · BTU/Wh | 10–11 | 557 / 557 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 557 / 557 |
| Cooling capacity · BTU/h | 22,600–25,000 | 557 / 557 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,200–25,800 | 557 / 557 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 16,800–18,700 | 557 / 557 |
| Heating capacity at 5°F / −15°C · BTU/h | 18,700–20,600 | 557 / 557 |
| COP at 5°F / −15°C | 1.85–2.06 | 557 / 557 |
| Equipment / loop type | HP - Split System | 557 / 557 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 557 / 557 |
| Compressor staging | Continuously variable | 557 / 557 |
| Connected capability | No | 557 / 557 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CSAH*3612AM*+ furnace: 59TP7A120V24**22Cold climate designationAHRI reference: 218473787 | 16.00 | 8.50 | 19200 | 1.92 | EPA 4625554 → |
CSAH*3612AM*+ furnace: 59TP7A100V21**22Cold climate designationAHRI reference: 218473786 | 16.00 | 8.50 | 19300 | 1.92 | EPA 4625555 → |
CSAH*3612AM*+ furnace: 59TP7A100V21**20Cold climate designationAHRI reference: 218473785 | 16.00 | 8.50 | 19200 | 1.92 | EPA 4625556 → |
CSAH*3612AM*+ furnace: 59TP7A080V21**20Cold climate designationAHRI reference: 218473784 | 16.00 | 8.50 | 19300 | 1.92 | EPA 4625557 → |
CSAH*3612AM*+ furnace: 59TP7A080V17**16Cold climate designationAHRI reference: 218473783 | 16.00 | 8.50 | 19200 | 1.92 | EPA 4625558 → |
CSAH*3612AM*+ furnace: 59TP7A060V17**16Cold climate designationAHRI reference: 218473782 | 16.00 | 8.50 | 19300 | 1.92 | EPA 4625559 → |
CSAH*3612AM*+ furnace: 59TP6C120V24**22Cold climate designationAHRI reference: 218473781 | 16.00 | 8.50 | 19200 | 1.92 | EPA 4625560 → |
CSAH*3612AM*+ furnace: 59TP6C100V21**22Cold climate designationAHRI reference: 218473780 | 16.00 | 8.50 | 19300 | 1.92 | EPA 4625561 → |
CSAH*3612AM*+ furnace: 59TP6C100V21**20Cold climate designationAHRI reference: 218473779 | 16.00 | 8.50 | 19200 | 1.92 | EPA 4625562 → |
CSAH*3612AM*+ furnace: 59TP6C080V21**20Cold climate designationAHRI reference: 218473778 | 16.00 | 8.50 | 19300 | 1.92 | EPA 4625563 → |
CSAH*3612AM*+ furnace: 59TP6C080V17**16Cold climate designationAHRI reference: 218473777 | 16.00 | 8.50 | 19200 | 1.92 | EPA 4625564 → |
CSAH*3612AM*+ furnace: 59TP6C060V17**16Cold climate designationAHRI reference: 218473776 | 16.00 | 8.50 | 19300 | 1.92 | EPA 4625565 → |
CSAH*3612AM*+ furnace: 59TP6C060V14**12Cold climate designationAHRI reference: 218473775 | 16.00 | 8.50 | 19200 | 1.92 | EPA 4625566 → |
CSAH*3612AM*+ furnace: 59TP6C040V17**12Cold climate designationAHRI reference: 218473774 | 16.00 | 8.50 | 19400 | 1.92 | EPA 4625567 → |
CSAH*3612AM*+ furnace: 59SU5B080M21**20Cold climate designationAHRI reference: 218473770 | 16.00 | 8.50 | 19200 | 1.92 | EPA 4625571 → |
CSAH*3612AM*+ furnace: 59SU5B060M17**16Cold climate designationAHRI reference: 218473769 | 16.00 | 8.50 | 19200 | 1.90 | EPA 4625572 → |
CSAH*3612AM*+ furnace: 59SU5B040M17**12Cold climate designationAHRI reference: 218473768 | 16.00 | 8.50 | 19300 | 1.90 | EPA 4625573 → |
CSAH*3612AM*+ furnace: 59SP6B120V24**22Cold climate designationAHRI reference: 218473767 | 16.00 | 8.50 | 19200 | 1.92 | EPA 4625574 → |
CSAH*3612AM*+ furnace: 59SP6B080V21**20Cold climate designationAHRI reference: 218473765 | 16.00 | 8.50 | 19300 | 1.92 | EPA 4625576 → |
CSAH*3612AM*+ furnace: 59SP6B080V17**16Cold climate designationAHRI reference: 218473764 | 16.00 | 8.50 | 19200 | 1.92 | EPA 4625577 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →