Carrier / AIR-SOURCE HEAT PUMP

37MUHAQ24AA3+KSAIC0701230

Crossover Heat Pump

557 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range8.1–9.5BTU/Wh
Cooling capacity22,600–25,000BTU/h

Each efficiency range summarizes published EPA records for 37MUHAQ24AA3+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 557 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18557 / 557
EER2 · BTU/Wh10–11557 / 557
HSPF2 · BTU/Wh8.1–9.5557 / 557
Cooling capacity · BTU/h22,600–25,000557 / 557
Heating capacity at 47°F / 8.3°C · BTU/h22,200–25,800557 / 557
Heating capacity at 17°F / −8.3°C · BTU/h16,800–18,700557 / 557
Heating capacity at 5°F / −15°C · BTU/h18,700–20,600557 / 557
COP at 5°F / −15°C1.85–2.06557 / 557
Equipment / loop typeHP - Split System557 / 557
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)557 / 557
Compressor stagingContinuously variable557 / 557
Connected capabilityNo557 / 557

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FT5AN(B,X)C36L*Cold climate designationAHRI reference: 21847379418.009.00190002.02EPA 4625549
CAA**2517AM*+ furnace: 58TP*B045V14**12Cold climate designationAHRI reference: 21847349818.008.50189001.92EPA 4625835
CAA**2517AM*+ furnace: 58SU*B060M17**16Cold climate designationAHRI reference: 21847349718.009.00191002.02EPA 4625836
CAA**2517AM*+ furnace: 58SP*B045V14**12Cold climate designationAHRI reference: 21847349218.008.50189001.92EPA 4625841
FG5ANXC36L*Cold climate designationAHRI reference: 21847601518.009.00190002.02EPA 4627091
FT5ANXB24L*Cold climate designationAHRI reference: 21847301117.509.50190002.04EPA 4625034
CAA**3721AM*+ furnace: 59SU5B100M21**22Cold climate designationAHRI reference: 21847362917.509.00190002.02EPA 4625704
CAA**3721AM*+ furnace: 59SU5B100M21**20Cold climate designationAHRI reference: 21847362817.508.50188001.92EPA 4625705
CAA**3721AM*+ furnace: 58SU*B040M17**12Cold climate designationAHRI reference: 21847361217.508.50188001.90EPA 4625721
CAA**3717AM*+ furnace: 58TP*B070V14**12Cold climate designationAHRI reference: 21847358817.508.50191001.92EPA 4625745
CAA**3717AM*+ furnace: 58TP*B045V14**12Cold climate designationAHRI reference: 21847358717.508.50191001.92EPA 4625746
CAA**3717AM*+ furnace: 58SU*B060M17**16Cold climate designationAHRI reference: 21847358617.509.00192002.02EPA 4625747
CAA**3717AM*+ furnace: 58SP*B070V17**16Cold climate designationAHRI reference: 21847358317.509.00193002.04EPA 4625750
CAA**3717AM*+ furnace: 58SP*B070V14**12Cold climate designationAHRI reference: 21847358217.508.50191001.92EPA 4625751
CAA**3717AM*+ furnace: 58SP*B045V14**12Cold climate designationAHRI reference: 21847358117.508.50191001.92EPA 4625752
CAA**3617AM*+ furnace: 58TP*B070V14**12Cold climate designationAHRI reference: 21847356117.508.50194001.90EPA 4625772
CAA**3617AM*+ furnace: 58SU*B060M17**16Cold climate designationAHRI reference: 21847355917.508.50193001.90EPA 4625774
CAA**3617AM*+ furnace: 58SU*B040M17**12Cold climate designationAHRI reference: 21847355817.508.50194001.90EPA 4625775
CAA**3617AM*+ furnace: 58SP*B070V14**12Cold climate designationAHRI reference: 21847355517.508.50194001.90EPA 4625778
CAA**3017AM*+ furnace: 58TP*B070V14**12Cold climate designationAHRI reference: 21847353417.508.50195001.90EPA 4625799

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →