Carrier / AIR-SOURCE HEAT PUMP

27VPA960A*030*

Performance 19 SEER2 VS HP · source records, page 3

225 published source records · source checked Sep 21, 2026

SEER2 range15.2–17.5BTU/Wh
HSPF2 range8–9BTU/Wh
Cooling capacity54,000–57,500BTU/h

Each efficiency range summarizes published EPA records for 27VPA960A*030*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 225 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17.5225 / 225
EER2 · BTU/Wh10–12225 / 225
HSPF2 · BTU/Wh8–9225 / 225
Cooling capacity · BTU/h54,000–57,500225 / 225
Heating capacity at 47°F / 8.3°C · BTU/h56,500–62,000225 / 225
Heating capacity at 17°F / −8.3°C · BTU/h48,000–50,500225 / 225
Heating capacity at 5°F / −15°C · BTU/h39,000–42,000225 / 225
COP at 5°F / −15°C1.94–2.16225 / 225
Equipment / loop typeHP - Split System225 / 225
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)225 / 225
Compressor stagingContinuously variable225 / 225
Connected capabilityNo225 / 225

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAMA6021XMA*+ furnace: 58SU*B100M21**20AHRI reference: 21790817916.008.00395001.94EPA 4534690
CVAMA6021XMA*+ furnace: 58TN*B090C21**20AHRI reference: 21790818216.008.00395001.94EPA 4534691
CVAMA6021XMA*+ furnace: 58TP*B110V21**22AHRI reference: 21790818616.008.00390001.96EPA 4534693
CVAMA6021XMA*+ furnace: 59MN7C100C21**22AHRI reference: 21790819116.008.00395001.94EPA 4534695
CVAMA6021XMA*+ furnace: 59TP6C100V21**20AHRI reference: 21790820316.008.00395001.94EPA 4534702
CVAMA6021XMA*+ furnace: 59TP6C100V21**22AHRI reference: 21790820416.008.00395001.96EPA 4534703
CVAMA6021XMA*+ furnace: 59TP7A100V21**20AHRI reference: 21790820616.008.00395001.94EPA 4534704
CVAMA6021XMA*+ furnace: 59TP7A100V21**22AHRI reference: 21790820716.008.00395001.96EPA 4534706
CVAMA6124XMA*+ furnace: 58SP*B135V24**22AHRI reference: 21790823916.008.00410001.96EPA 4534710
CVAMA6124XMA*+ furnace: 58SU*B080M21**20AHRI reference: 21790824016.008.00410001.96EPA 4534711
CVAMA6124XMA*+ furnace: 58TP*B135V24**22AHRI reference: 21790824816.008.00405001.98EPA 4534717
CVAMA6021XMA*+ furnace: 59SU5B100M21**22AHRI reference: 21790819716.008.00395001.96EPA 4535246
CAA**6124AM*+ furnace: 59TP7A100V21**22AHRI reference: 21791835316.009.00405002.14EPA 4537050
CAA**6124AM*+ furnace: 59TP7A120V24**22Cold climate designationAHRI reference: 21791835416.009.00410002.14EPA 4537051
CAA**6124AM*+ furnace: OVLAAB060154Cold climate designationAHRI reference: 21791835516.009.00410002.14EPA 4537052
F55AA*D60L*AHRI reference: 21791838016.009.00400002.16EPA 4537057
CAA**6124AM*+ furnace: 58TP*B110V21**22AHRI reference: 21791832716.009.00405002.14EPA 4537396
CAA**6124AM*+ furnace: 58TP*B135V24**22AHRI reference: 21791832816.009.00405002.14EPA 4537397
CAA**6124AM*+ furnace: 59CU5B100C21**22AHRI reference: 21791832916.008.50405002.05EPA 4537398
CAA**6124AM*+ furnace: 59MN7C100C21**22Cold climate designationAHRI reference: 21791833116.009.00410002.14EPA 4537400