Carrier / AIR-SOURCE HEAT PUMP

27VPA960A*030*

Performance 19 SEER2 VS HP

225 published source records · source checked Sep 21, 2026

SEER2 range15.2–17.5BTU/Wh
HSPF2 range8–9BTU/Wh
Cooling capacity54,000–57,500BTU/h

Each efficiency range summarizes published EPA records for 27VPA960A*030*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 225 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17.5225 / 225
EER2 · BTU/Wh10–12225 / 225
HSPF2 · BTU/Wh8–9225 / 225
Cooling capacity · BTU/h54,000–57,500225 / 225
Heating capacity at 47°F / 8.3°C · BTU/h56,500–62,000225 / 225
Heating capacity at 17°F / −8.3°C · BTU/h48,000–50,500225 / 225
Heating capacity at 5°F / −15°C · BTU/h39,000–42,000225 / 225
COP at 5°F / −15°C1.94–2.16225 / 225
Equipment / loop typeHP - Split System225 / 225
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)225 / 225
Compressor stagingContinuously variable225 / 225
Connected capabilityNo225 / 225

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FT5BD6021X*Cold climate designationAHRI reference: 21869556917.508.10400002.00EPA 4683258 →
FT5ANBD60L*Cold climate designationAHRI reference: 21790817017.009.00410002.12EPA 4534684 →
FG5ANBD60L*Cold climate designationAHRI reference: 21791838117.009.00410002.12EPA 4537058 →
CAA**6124AM*+ furnace: 58CU*B080C21**20AHRI reference: 21791831516.508.50405002.05EPA 4540871 →
CAA**6124AM*+ furnace: 58SU*B080M21**20AHRI reference: 21791832016.508.50405002.05EPA 4540877 →
CVAVA6021XMA*+ furnace: 59TP6C100V21**22AHRI reference: 21790830516.008.00395001.96EPA 4529821 →
CVAVA6021XMA*+ furnace: 58TN*B090C21**20AHRI reference: 21790828516.008.00395001.94EPA 4529827 →
CVAVA6021XMA*+ furnace: 58TP*B110V21**22AHRI reference: 21790828816.008.00395001.96EPA 4529829 →
CVAMA6124XMA*+ furnace: 59TP6C100V21**22AHRI reference: 21790826816.008.00405001.96EPA 4530069 →
CVAMA6124XMA*+ furnace: 59TP7A100V21**22AHRI reference: 21790827216.008.00405001.96EPA 4530070 →
CVAVA6021XMA*+ furnace: 58SP*B110V21**22AHRI reference: 21790828016.008.00395001.96EPA 4530074 →
CVAVA6021XMA*+ furnace: 58SU*B080M21**20AHRI reference: 21790828216.008.00395001.96EPA 4530076 →
CVAVA6121XMA*+ furnace: 59TN7A100C21**22AHRI reference: 21790836416.008.00405001.96EPA 4530817 →
CVAVA6121XMA*+ furnace: 59TP6C100V21**22AHRI reference: 21790836716.008.00400001.96EPA 4530819 →
CVAVA6121XMA*+ furnace: 59TP7A100V21**22AHRI reference: 21790837016.008.00400001.96EPA 4530821 →
CVAVA6124XMA*+ furnace: 58SU*B080M21**20AHRI reference: 21790837616.008.00410001.96EPA 4530828 →
CVAVA6124XMA*+ furnace: 58TP*B135V24**22AHRI reference: 21790838416.008.00410001.96EPA 4530830 →
CVAVA6124XMA*+ furnace: 59TP7A100V21**22AHRI reference: 21790840316.008.00410001.96EPA 4530831 →
CVAVA6124XMA*+ furnace: 59TP6C100V21**22AHRI reference: 21790840116.008.00410001.96EPA 4530836 →
CVAVA6121XMA*+ furnace: 58SU*B100M21**20AHRI reference: 21790834516.008.00405001.96EPA 4534155 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.