Carrier / AIR-SOURCE HEAT PUMP

27VPA960A*030*

Performance 19 SEER2 VS HP

225 published source records · source checked Sep 21, 2026

SEER2 range15.2–17.5BTU/Wh
HSPF2 range8–9BTU/Wh
Cooling capacity54,000–57,500BTU/h

Each efficiency range summarizes published EPA records for 27VPA960A*030*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 225 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17.5225 / 225
EER2 · BTU/Wh10–12225 / 225
HSPF2 · BTU/Wh8–9225 / 225
Cooling capacity · BTU/h54,000–57,500225 / 225
Heating capacity at 47°F / 8.3°C · BTU/h56,500–62,000225 / 225
Heating capacity at 17°F / −8.3°C · BTU/h48,000–50,500225 / 225
Heating capacity at 5°F / −15°C · BTU/h39,000–42,000225 / 225
COP at 5°F / −15°C1.94–2.16225 / 225
Equipment / loop typeHP - Split System225 / 225
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)225 / 225
Compressor stagingContinuously variable225 / 225
Connected capabilityNo225 / 225

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FT5BD6021X*Cold climate designationAHRI reference: 21869556917.508.10400002.00EPA 4683258
FT5ANBD60L*Cold climate designationAHRI reference: 21790817017.009.00410002.12EPA 4534684
FG5ANBD60L*Cold climate designationAHRI reference: 21791838117.009.00410002.12EPA 4537058
CAA**6124AM*+ furnace: 58CU*B080C21**20AHRI reference: 21791831516.508.50405002.05EPA 4540871
CAA**6124AM*+ furnace: 58SU*B080M21**20AHRI reference: 21791832016.508.50405002.05EPA 4540877
CVAVA6021XMA*+ furnace: 59TP6C100V21**22AHRI reference: 21790830516.008.00395001.96EPA 4529821
CVAVA6021XMA*+ furnace: 58TN*B090C21**20AHRI reference: 21790828516.008.00395001.94EPA 4529827
CVAVA6021XMA*+ furnace: 58TP*B110V21**22AHRI reference: 21790828816.008.00395001.96EPA 4529829
CVAMA6124XMA*+ furnace: 59TP6C100V21**22AHRI reference: 21790826816.008.00405001.96EPA 4530069
CVAMA6124XMA*+ furnace: 59TP7A100V21**22AHRI reference: 21790827216.008.00405001.96EPA 4530070
CVAVA6021XMA*+ furnace: 58SP*B110V21**22AHRI reference: 21790828016.008.00395001.96EPA 4530074
CVAVA6021XMA*+ furnace: 58SU*B080M21**20AHRI reference: 21790828216.008.00395001.96EPA 4530076
CVAVA6121XMA*+ furnace: 59TN7A100C21**22AHRI reference: 21790836416.008.00405001.96EPA 4530817
CVAVA6121XMA*+ furnace: 59TP6C100V21**22AHRI reference: 21790836716.008.00400001.96EPA 4530819
CVAVA6121XMA*+ furnace: 59TP7A100V21**22AHRI reference: 21790837016.008.00400001.96EPA 4530821
CVAVA6124XMA*+ furnace: 58SU*B080M21**20AHRI reference: 21790837616.008.00410001.96EPA 4530828
CVAVA6124XMA*+ furnace: 58TP*B135V24**22AHRI reference: 21790838416.008.00410001.96EPA 4530830
CVAVA6124XMA*+ furnace: 59TP7A100V21**22AHRI reference: 21790840316.008.00410001.96EPA 4530831
CVAVA6124XMA*+ furnace: 59TP6C100V21**22AHRI reference: 21790840116.008.00410001.96EPA 4530836
CVAVA6121XMA*+ furnace: 58SU*B100M21**20AHRI reference: 21790834516.008.00405001.96EPA 4534155

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →