Carrier / AIR-SOURCE HEAT PUMP

27VPA948A*030*

Performance 19 SEER2 VS HP

534 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8.5–10BTU/Wh
Cooling capacity43,500–49,500BTU/h

Each efficiency range summarizes published EPA records for 27VPA948A*030*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 534 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19534 / 534
EER2 · BTU/Wh10–13.5534 / 534
HSPF2 · BTU/Wh8.5–10534 / 534
Cooling capacity · BTU/h43,500–49,500534 / 534
Heating capacity at 47°F / 8.3°C · BTU/h46,500–55,000534 / 534
Heating capacity at 17°F / −8.3°C · BTU/h38,500–47,000534 / 534
Heating capacity at 5°F / −15°C · BTU/h36,000–41,500534 / 534
COP at 5°F / −15°C1.95–2.32534 / 534
Equipment / loop typeHP - Split System534 / 534
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)534 / 534
Compressor stagingContinuously variable534 / 534
Connected capabilityNo534 / 534

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FG5ANBD60L*Cold climate designationAHRI reference: 21791493519.0010.00360002.32EPA 4533121
FT5ANBD60L*Cold climate designationAHRI reference: 21790791519.0010.00360002.32EPA 4534698
FT5BD6021X*Cold climate designationAHRI reference: 21869555319.0010.00385002.12EPA 4683274
FT5BD4821X*Cold climate designationAHRI reference: 21869553719.009.50385002.12EPA 4683290
FG5ANXC48L*Cold climate designationAHRI reference: 21791491918.009.00364002.10EPA 4533105
FT5AN(B,X)C48L*Cold climate designationAHRI reference: 21790791418.009.00364002.10EPA 4533905
CAA**6121AM*+ furnace: 58SU*B080M21**20Cold climate designationAHRI reference: 21791475817.509.00368002.10EPA 4535411
CAA**4821AM*+ furnace: 59TP6C100V21**22Cold climate designationAHRI reference: 21791471017.009.00368002.12EPA 4531248
CAA**4821AM*+ furnace: 59TP7A100V21**22Cold climate designationAHRI reference: 21791471417.009.00368002.12EPA 4531255
CAA**6024AM*+ furnace: 58SU*B080M21**20Cold climate designationAHRI reference: 21791472117.009.00368002.10EPA 4531257
F55AA*C48L*Cold climate designationAHRI reference: 21791491817.009.50360002.24EPA 4532395
CAA**4821AM*+ furnace: 58CU*B080C21**20Cold climate designationAHRI reference: 21791468117.009.00368002.08EPA 4533937
CAA**4821AM*+ furnace: 58SU*B080M21**20Cold climate designationAHRI reference: 21791468617.009.00366002.10EPA 4533942
CVAMA6021XMA*+ furnace: 59TP6C100V21**22Cold climate designationAHRI reference: 21790800917.009.50400002.24EPA 4534545
CVAMA6021XMA*+ furnace: 59TP7A100V21**22Cold climate designationAHRI reference: 21790801217.009.50400002.24EPA 4534548
CVAVA6124XMA*+ furnace: 58TP*B135V24**22Cold climate designationAHRI reference: 21790814517.009.50405002.24EPA 4534661
CVAVA6121XMA*+ furnace: 58TN*B090C21**20Cold climate designationAHRI reference: 21790811117.009.50405002.24EPA 4535356
CVAVA6021XMA*+ furnace: 59TP6C100V21**22Cold climate designationAHRI reference: 21790809917.009.50400002.24EPA 4535368
CVAVA6021XMA*+ furnace: 59TP7A100V21**22Cold climate designationAHRI reference: 21790810217.009.50400002.24EPA 4535371
CVAVA6121XMA*+ furnace: 58CU*B080C21**20Cold climate designationAHRI reference: 21790810317.009.00405002.10EPA 4535372

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.