Heating performance & equipment details
Ranges include the 1,222 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.5 | 1,222 / 1,222 |
| EER2 · BTU/Wh | 11.5–14 | 1,222 / 1,222 |
| HSPF2 · BTU/Wh | 8–10 | 1,222 / 1,222 |
| Cooling capacity · BTU/h | 22,200–25,400 | 1,222 / 1,222 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,400–25,800 | 1,222 / 1,222 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,800–25,200 | 1,222 / 1,222 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–22,200 | 1,222 / 1,222 |
| COP at 5°F / −15°C | 1.74–2.02 | 1,222 / 1,222 |
| Equipment / loop type | HP - Split System | 1,222 / 1,222 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 1,222 / 1,222 |
| Compressor staging | Continuously variable | 1,222 / 1,222 |
| Connected capability | No | 1,222 / 1,222 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CVAVA3621XMA*+ furnace: 59TP6C100V21**20Cold climate designationAHRI reference: 217934453 | 19.00 | 8.50 | 21400 | 1.88 | EPA 4544148 → |
CVAVA3621XMA*+ furnace: 59TP7A080V17**16Cold climate designationAHRI reference: 217934456 | 19.00 | 8.50 | 21200 | 1.90 | EPA 4544149 → |
CVAVA3621XMA*+ furnace: 59TP6C100V21**22Cold climate designationAHRI reference: 217934454 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4544150 → |
CVAVA3621XMA*+ furnace: 59TP7A060V17**16Cold climate designationAHRI reference: 217934455 | 19.00 | 8.50 | 21200 | 1.88 | EPA 4544151 → |
CVAVA3621XMA*+ furnace: 59TP7A080V21**20Cold climate designationAHRI reference: 217934457 | 19.00 | 8.50 | 21400 | 1.88 | EPA 4544152 → |
CVAVA3621XMA*+ furnace: 59TP7A100V21**20Cold climate designationAHRI reference: 217934458 | 19.00 | 8.50 | 21400 | 1.88 | EPA 4544153 → |
CVAVA3621XMA*+ furnace: 59TP7A100V21**22Cold climate designationAHRI reference: 217934459 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4544154 → |
CVAVA3721XMA*+ furnace: 58CU*B040C17**12Cold climate designationAHRI reference: 217934464 | 19.00 | 8.50 | 21200 | 1.90 | EPA 4545202 → |
CVAVA3721XMA*+ furnace: 58CU*B060C17**16Cold climate designationAHRI reference: 217934465 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4545203 → |
CVAVA3721XMA*+ furnace: 58CU*B100C21**20Cold climate designationAHRI reference: 217934467 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4545204 → |
CVAVA3621XMA*+ furnace: OVMAAB042112Cold climate designationAHRI reference: 217934463 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4545205 → |
CVAVA3721XMA*+ furnace: 58SP*B070V17**16Cold climate designationAHRI reference: 217934468 | 19.00 | 8.50 | 21400 | 1.88 | EPA 4545206 → |
CVAVA3721XMA*+ furnace: 58SU*B040M17**12Cold climate designationAHRI reference: 217934471 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4545207 → |
CVAVA3721XMA*+ furnace: 58SU*B060M17**16Cold climate designationAHRI reference: 217934472 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4545208 → |
CVAVA3721XMA*+ furnace: 58SP*B090V17**16Cold climate designationAHRI reference: 217934469 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4545209 → |
CVAVA3721XMA*+ furnace: 58SP*B090V21**20Cold climate designationAHRI reference: 217934470 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4545210 → |
CVAVA3721XMA*+ furnace: 58CU*B080C21**20Cold climate designationAHRI reference: 217934466 | 19.00 | 8.50 | 21200 | 1.90 | EPA 4545212 → |
CVAVA3721XMA*+ furnace: 58SU*B080M21**20Cold climate designationAHRI reference: 217934473 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4545371 → |
CVAVA3721XMA*+ furnace: 58SU*B100M21**20Cold climate designationAHRI reference: 217934474 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4545372 → |
CVAVA3721XMA*+ furnace: 58TN*B045C17**12Cold climate designationAHRI reference: 217934475 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4545373 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →