27VPA924A*030*
Performance 19 SEER2 VS HP · source records, page 50
1,222 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 27VPA924A*030*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 1,222 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.5 | 1,222 / 1,222 |
| EER2 · BTU/Wh | 11.5–14 | 1,222 / 1,222 |
| HSPF2 · BTU/Wh | 8–10 | 1,222 / 1,222 |
| Cooling capacity · BTU/h | 22,200–25,400 | 1,222 / 1,222 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,400–25,800 | 1,222 / 1,222 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,800–25,200 | 1,222 / 1,222 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–22,200 | 1,222 / 1,222 |
| COP at 5°F / −15°C | 1.74–2.02 | 1,222 / 1,222 |
| Equipment / loop type | HP - Split System | 1,222 / 1,222 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 1,222 / 1,222 |
| Compressor staging | Continuously variable | 1,222 / 1,222 |
| Connected capability | No | 1,222 / 1,222 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CSAH*3012AM*+ furnace: 59SU5B060M17**16Cold climate designationAHRI reference: 217934688 | 16.50 | 9.50 | 21200 | 1.94 | EPA 4542159 → |
CSAH*3012AM*+ furnace: 58SP*B135V24**22Cold climate designationAHRI reference: 217934807 | 16.50 | 9.00 | 21400 | 1.85 | EPA 4542525 → |
CSAH*3012AM*+ furnace: 58TN*B090C17**16Cold climate designationAHRI reference: 217934808 | 16.50 | 9.50 | 21200 | 1.92 | EPA 4542526 → |
CSAH*3012AM*+ furnace: 58TP*B135V24**22Cold climate designationAHRI reference: 217934809 | 16.50 | 9.00 | 21400 | 1.85 | EPA 4542527 → |
CSAH*3012AM*+ furnace: 58SU*B080M21**20Cold climate designationAHRI reference: 217934819 | 16.50 | 9.50 | 21200 | 1.92 | EPA 4542536 → |
CAA**2417AM*+ furnace: OVLAAB036098Cold climate designationAHRI reference: 217934826 | 16.50 | 9.00 | 21600 | 1.82 | EPA 4542543 → |
CSAH*2412AM*+ furnace: 58SU*B060M17**16Cold climate designationAHRI reference: 217934847 | 16.50 | 9.00 | 21200 | 1.85 | EPA 4542566 → |
CSAH*2412AM*+ furnace: 58TP*B110V21**22Cold climate designationAHRI reference: 217934848 | 16.50 | 9.00 | 21400 | 1.80 | EPA 4542567 → |
CSAH*3012AM*+ furnace: 58TP*B070V17**16Cold climate designationAHRI reference: 217934849 | 16.50 | 9.50 | 21200 | 1.92 | EPA 4542568 → |
CSAH*3012AM*+ furnace: 59TN6C080C17**14Cold climate designationAHRI reference: 217934850 | 16.50 | 9.50 | 21400 | 1.92 | EPA 4542569 → |
CSAH*3612AM*+ furnace: 59TN6C120C24**22Cold climate designationAHRI reference: 217934851 | 16.50 | 9.50 | 21200 | 1.94 | EPA 4542570 → |
CSAH*3612AM*+ furnace: 59TN7A120C24**22Cold climate designationAHRI reference: 217934852 | 16.50 | 9.50 | 21200 | 1.94 | EPA 4542571 → |
CVAVA3014XMA*+ furnace: 59TN6C040C14**10Cold climate designationAHRI reference: 217934290 | 16.50 | 8.50 | 21600 | 1.90 | EPA 4542773 → |
CVAVA3014XMA*+ furnace: 59TP6C040V14**10Cold climate designationAHRI reference: 217934291 | 16.50 | 8.50 | 21600 | 1.90 | EPA 4542774 → |
CSAH*2412AM*+ furnace: 59TP6C100V21**22Cold climate designationAHRI reference: 217934885 | 16.50 | 9.00 | 21400 | 1.85 | EPA 4543019 → |
CSAH*2412AM*+ furnace: 59TP7A100V21**22Cold climate designationAHRI reference: 217934886 | 16.50 | 9.00 | 21400 | 1.85 | EPA 4543020 → |
CSAH*3012AM*+ furnace: 58CU*B060C17**16Cold climate designationAHRI reference: 217934887 | 16.50 | 9.50 | 21200 | 1.92 | EPA 4543021 → |
CSAH*3612AM*+ furnace: 59MN7C080C21**20Cold climate designationAHRI reference: 217934889 | 16.50 | 9.50 | 21200 | 1.94 | EPA 4543022 → |
CSAH*3012AM*+ furnace: 59SU5B080M21**20Cold climate designationAHRI reference: 217934888 | 16.50 | 9.00 | 21400 | 1.85 | EPA 4543023 → |
CAA**3617AM*+ furnace: 59TP6C040V14**10Cold climate designationAHRI reference: 217934890 | 16.50 | 9.00 | 21400 | 1.84 | EPA 4543024 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →