Performance 19 SEER2 VS HP · source records, page 42
1,222 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 27VPA924A*030*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 1,222 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.5 | 1,222 / 1,222 |
| EER2 · BTU/Wh | 11.5–14 | 1,222 / 1,222 |
| HSPF2 · BTU/Wh | 8–10 | 1,222 / 1,222 |
| Cooling capacity · BTU/h | 22,200–25,400 | 1,222 / 1,222 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,400–25,800 | 1,222 / 1,222 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,800–25,200 | 1,222 / 1,222 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–22,200 | 1,222 / 1,222 |
| COP at 5°F / −15°C | 1.74–2.02 | 1,222 / 1,222 |
| Equipment / loop type | HP - Split System | 1,222 / 1,222 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 1,222 / 1,222 |
| Compressor staging | Continuously variable | 1,222 / 1,222 |
| Connected capability | No | 1,222 / 1,222 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CVAMA3117XMA*+ furnace: 59SP6B040V14**10Cold climate designationAHRI reference: 217934077 | 17.50 | 8.50 | 22000 | 1.92 | EPA 4546405 → |
CVAMA3117XMA*+ furnace: 59TN6C040C14**10Cold climate designationAHRI reference: 217934084 | 17.50 | 8.50 | 22000 | 1.92 | EPA 4546413 → |
CVAMA3117XMA*+ furnace: 59TP6C040V14**10Cold climate designationAHRI reference: 217934089 | 17.50 | 8.50 | 21800 | 1.92 | EPA 4546417 → |
CAA**2417AM*+ furnace: 58SU*B060M17**16Cold climate designationAHRI reference: 217934641 | 17.50 | 9.50 | 21200 | 1.90 | EPA 4546679 → |
CAA**3717AM*+ furnace: 59CU5B060C17**16Cold climate designationAHRI reference: 217934644 | 17.50 | 9.50 | 21200 | 1.90 | EPA 4546728 → |
CAA**2414AM*+ furnace: 58SP*B070V14**12Cold climate designationAHRI reference: 217934666 | 17.50 | 9.50 | 21200 | 1.92 | EPA 4546757 → |
CAA**2417AM*+ furnace: 58TP*B070V17**16Cold climate designationAHRI reference: 217934668 | 17.50 | 9.50 | 21200 | 1.94 | EPA 4546758 → |
CAA**2414AM*+ furnace: 58TP*B070V14**12Cold climate designationAHRI reference: 217934667 | 17.50 | 9.50 | 21200 | 1.92 | EPA 4546759 → |
CAA**2417AM*+ furnace: 59TN6C080C17**14Cold climate designationAHRI reference: 217934669 | 17.50 | 9.50 | 21200 | 1.92 | EPA 4546760 → |
CAA**2517AM*+ furnace: 59SP6B040V17**12Cold climate designationAHRI reference: 217934670 | 17.50 | 9.50 | 21400 | 1.90 | EPA 4546761 → |
CAA**2517AM*+ furnace: 59TP6C040V17**12Cold climate designationAHRI reference: 217934671 | 17.50 | 9.50 | 21400 | 1.90 | EPA 4546762 → |
CAA**3617AM*+ furnace: 59TN7A060C17**16Cold climate designationAHRI reference: 217934672 | 17.50 | 9.50 | 21200 | 1.92 | EPA 4546763 → |
CVAVA3117XMA*+ furnace: 59TP6C040V14**10Cold climate designationAHRI reference: 217934357 | 17.50 | 8.50 | 22200 | 1.92 | EPA 4546811 → |
CVAVA3617XMA*+ furnace: 59SP6B040V14**10Cold climate designationAHRI reference: 217934381 | 17.50 | 8.50 | 22000 | 1.90 | EPA 4546836 → |
CVAVA3617XMA*+ furnace: 59SP6B040V17**12Cold climate designationAHRI reference: 217934382 | 17.50 | 8.50 | 21800 | 1.92 | EPA 4546837 → |
CVAVA3617XMA*+ furnace: 59TP6C040V17**12Cold climate designationAHRI reference: 217934393 | 17.50 | 8.50 | 21800 | 1.92 | EPA 4546922 → |
CSAH*3012AM*+ furnace: 58SU*B060M17**16Cold climate designationAHRI reference: 217934932 | 17.50 | 9.50 | 21200 | 1.92 | EPA 4546978 → |
CAA**2417AM*+ furnace: 58TN*B070C14**12Cold climate designationAHRI reference: 217934924 | 17.50 | 9.50 | 21200 | 1.92 | EPA 4547006 → |
CAA**2417AM*+ furnace: 58SP*B070V14**12Cold climate designationAHRI reference: 217934923 | 17.50 | 9.50 | 21200 | 1.92 | EPA 4547007 → |
CAA**2417AM*+ furnace: 58TP*B070V14**12Cold climate designationAHRI reference: 217934925 | 17.50 | 9.50 | 21200 | 1.92 | EPA 4547008 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →