Performance 19 SEER2 VS HP · source records, page 24
1,222 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 27VPA924A*030*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 1,222 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.5 | 1,222 / 1,222 |
| EER2 · BTU/Wh | 11.5–14 | 1,222 / 1,222 |
| HSPF2 · BTU/Wh | 8–10 | 1,222 / 1,222 |
| Cooling capacity · BTU/h | 22,200–25,400 | 1,222 / 1,222 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,400–25,800 | 1,222 / 1,222 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,800–25,200 | 1,222 / 1,222 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–22,200 | 1,222 / 1,222 |
| COP at 5°F / −15°C | 1.74–2.02 | 1,222 / 1,222 |
| Equipment / loop type | HP - Split System | 1,222 / 1,222 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 1,222 / 1,222 |
| Compressor staging | Continuously variable | 1,222 / 1,222 |
| Connected capability | No | 1,222 / 1,222 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CVAVA3621XMA*+ furnace: OVLAAB036098Cold climate designationAHRI reference: 217934460 | 18.50 | 8.50 | 21600 | 1.90 | EPA 4544155 → |
CVAVA2417XMA*+ furnace: 58CU*B040C17**12Cold climate designationAHRI reference: 217934191 | 18.50 | 8.50 | 20800 | 1.86 | EPA 4545097 → |
CVAVA2417XMA*+ furnace: 58CU*B060C17**16Cold climate designationAHRI reference: 217934192 | 18.50 | 8.50 | 20800 | 1.86 | EPA 4545098 → |
CVAVA2417XMA*+ furnace: 58SP*B070V14**12Cold climate designationAHRI reference: 217934194 | 18.50 | 8.50 | 20800 | 1.86 | EPA 4545100 → |
CVAVA2417XMA*+ furnace: 58SP*B090V17**16Cold climate designationAHRI reference: 217934196 | 18.50 | 8.50 | 20800 | 1.86 | EPA 4545102 → |
CVAVA2417XMA*+ furnace: 58SU*B060M17**16Cold climate designationAHRI reference: 217934198 | 18.50 | 8.50 | 21000 | 1.88 | EPA 4545103 → |
CVAVA2417XMA*+ furnace: 58SU*B040M17**12Cold climate designationAHRI reference: 217934197 | 18.50 | 8.50 | 20800 | 1.86 | EPA 4545104 → |
CVAVA2417XMA*+ furnace: 58TN*B070C14**12Cold climate designationAHRI reference: 217934200 | 18.50 | 8.50 | 20800 | 1.86 | EPA 4545106 → |
CVAVA2417XMA*+ furnace: 58TN*B070C17**16Cold climate designationAHRI reference: 217934201 | 18.50 | 8.50 | 21200 | 1.86 | EPA 4545107 → |
CVAVA2417XMA*+ furnace: 58TP*B070V14**12Cold climate designationAHRI reference: 217934204 | 18.50 | 8.50 | 20800 | 1.86 | EPA 4545110 → |
CVAVA2417XMA*+ furnace: 58TP*B070V17**16Cold climate designationAHRI reference: 217934205 | 18.50 | 8.50 | 20800 | 1.86 | EPA 4545111 → |
CVAVA2417XMA*+ furnace: 58TP*B090V17**16Cold climate designationAHRI reference: 217934206 | 18.50 | 8.50 | 20800 | 1.86 | EPA 4545112 → |
CVAVA2417XMA*+ furnace: 59TN6C080C17**14Cold climate designationAHRI reference: 217934219 | 18.50 | 8.50 | 20800 | 1.86 | EPA 4545127 → |
CVAVA2514XMA*+ furnace: 58SP*B070V14**12Cold climate designationAHRI reference: 217934233 | 18.50 | 8.50 | 21000 | 1.88 | EPA 4545139 → |
CVAVA2514XMA*+ furnace: 58TP*B070V14**12Cold climate designationAHRI reference: 217934236 | 18.50 | 8.50 | 21000 | 1.88 | EPA 4545140 → |
CVAVA2514XMA*+ furnace: 58TN*B070C14**12Cold climate designationAHRI reference: 217934234 | 18.50 | 8.50 | 21000 | 1.88 | EPA 4545141 → |
CAA**2517AM*+ furnace: 58SP*B045V14**12Cold climate designationAHRI reference: 217934768 | 18.50 | 10.00 | 21200 | 2.00 | EPA 4545167 → |
CAA**2517AM*+ furnace: 58TN*B070C17**16Cold climate designationAHRI reference: 217934769 | 18.50 | 10.00 | 21200 | 1.98 | EPA 4545168 → |
CAA**2517AM*+ furnace: 58TN*B090C17**16Cold climate designationAHRI reference: 217934770 | 18.50 | 10.00 | 21200 | 1.98 | EPA 4545169 → |
CAA**2517AM*+ furnace: 58TP*B045V14**12Cold climate designationAHRI reference: 217934771 | 18.50 | 10.00 | 21200 | 2.00 | EPA 4545170 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.