Carrier / AIR-SOURCE HEAT PUMP

27VPA924A*030*

Performance 19 SEER2 VS HP · source records, page 16

1,222 published source records · source checked Sep 21, 2026

SEER2 range15.2–19.5BTU/Wh
HSPF2 range8–10BTU/Wh
Cooling capacity22,200–25,400BTU/h

Each efficiency range summarizes published EPA records for 27VPA924A*030*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 1,222 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19.51,222 / 1,222
EER2 · BTU/Wh11.5–141,222 / 1,222
HSPF2 · BTU/Wh8–101,222 / 1,222
Cooling capacity · BTU/h22,200–25,4001,222 / 1,222
Heating capacity at 47°F / 8.3°C · BTU/h22,400–25,8001,222 / 1,222
Heating capacity at 17°F / −8.3°C · BTU/h19,800–25,2001,222 / 1,222
Heating capacity at 5°F / −15°C · BTU/h20,000–22,2001,222 / 1,222
COP at 5°F / −15°C1.74–2.021,222 / 1,222
Equipment / loop typeHP - Split System1,222 / 1,222
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)1,222 / 1,222
Compressor stagingContinuously variable1,222 / 1,222
Connected capabilityNo1,222 / 1,222

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CVAVA3117XMA*+ furnace: 59TN6C060C17**14Cold climate designationAHRI reference: 21793435419.008.50218001.90EPA 4546809
CVAVA3117XMA*+ furnace: 59TN7A060C17**16Cold climate designationAHRI reference: 21793435519.008.50218001.92EPA 4546810
CVAVA3117XMA*+ furnace: 59TN7A080C17**16Cold climate designationAHRI reference: 21793435619.008.50218001.90EPA 4546812
CVAVA3117XMA*+ furnace: 59TP6C060V17**16Cold climate designationAHRI reference: 21793436019.008.50218001.90EPA 4546815
CVAVA3117XMA*+ furnace: OVLAAB036098Cold climate designationAHRI reference: 21793436219.008.50218001.92EPA 4546816
CVAVA3117XMA*+ furnace: 59TP7A060V17**16Cold climate designationAHRI reference: 21793436119.008.50218001.90EPA 4546817
CVAVA3117XMA*+ furnace: OVMAAB036098Cold climate designationAHRI reference: 21793436319.008.50218001.92EPA 4546818
CVAVA3117XMA*+ furnace: OVMAAB042112Cold climate designationAHRI reference: 21793436419.008.50218001.90EPA 4546819
CVAVA3617XMA*+ furnace: 58CU*B060C17**16Cold climate designationAHRI reference: 21793436519.008.50216001.90EPA 4546820
CVAVA3617XMA*+ furnace: 58SP*B045V14**12Cold climate designationAHRI reference: 21793436619.008.50214001.90EPA 4546821
CVAVA3617XMA*+ furnace: 58SP*B070V14**12Cold climate designationAHRI reference: 21793436719.008.50214001.90EPA 4546822
CVAVA3617XMA*+ furnace: 58SP*B070V17**16Cold climate designationAHRI reference: 21793436819.008.50216001.90EPA 4546823
CVAVA3617XMA*+ furnace: 58SP*B090V17**16Cold climate designationAHRI reference: 21793436919.008.50214001.90EPA 4546824
CVAVA3617XMA*+ furnace: 58SU*B040M17**12Cold climate designationAHRI reference: 21793437019.008.50216001.90EPA 4546825
CVAVA3617XMA*+ furnace: 58SU*B060M17**16Cold climate designationAHRI reference: 21793437119.008.50214001.90EPA 4546827
CVAVA3617XMA*+ furnace: 58TN*B070C14**12Cold climate designationAHRI reference: 21793437319.008.50216001.90EPA 4546828
CVAVA3617XMA*+ furnace: 58TN*B070C17**16Cold climate designationAHRI reference: 21793437419.008.50216001.90EPA 4546829
CVAVA3617XMA*+ furnace: 58TN*B090C17**16Cold climate designationAHRI reference: 21793437519.008.50216001.90EPA 4546830
CVAVA3617XMA*+ furnace: 58TP*B045V14**12Cold climate designationAHRI reference: 21793437619.008.50214001.90EPA 4546831
CVAVA3617XMA*+ furnace: 58TP*B070V14**12Cold climate designationAHRI reference: 21793437719.008.50214001.90EPA 4546832

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →