27VPA924A*030*
Performance 19 SEER2 VS HP · source records, page 14
1,222 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 27VPA924A*030*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 1,222 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.5 | 1,222 / 1,222 |
| EER2 · BTU/Wh | 11.5–14 | 1,222 / 1,222 |
| HSPF2 · BTU/Wh | 8–10 | 1,222 / 1,222 |
| Cooling capacity · BTU/h | 22,200–25,400 | 1,222 / 1,222 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,400–25,800 | 1,222 / 1,222 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 19,800–25,200 | 1,222 / 1,222 |
| Heating capacity at 5°F / −15°C · BTU/h | 20,000–22,200 | 1,222 / 1,222 |
| COP at 5°F / −15°C | 1.74–2.02 | 1,222 / 1,222 |
| Equipment / loop type | HP - Split System | 1,222 / 1,222 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 1,222 / 1,222 |
| Compressor staging | Continuously variable | 1,222 / 1,222 |
| Connected capability | No | 1,222 / 1,222 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CVAMA3117XMA*+ furnace: 58TP*B090V17**16Cold climate designationAHRI reference: 217934073 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4546402 → |
CVAMA3117XMA*+ furnace: 59CU5B060C17**16Cold climate designationAHRI reference: 217934074 | 19.00 | 8.50 | 21600 | 1.92 | EPA 4546403 → |
CVAMA3117XMA*+ furnace: 59MN7C080C17**14Cold climate designationAHRI reference: 217934076 | 19.00 | 8.50 | 21600 | 1.92 | EPA 4546404 → |
CVAMA3217XMA*+ furnace: 58CU*B060C17**16Cold climate designationAHRI reference: 217934100 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4546406 → |
CVAMA3117XMA*+ furnace: 59SP6B060V17**16Cold climate designationAHRI reference: 217934080 | 19.00 | 8.50 | 21800 | 1.90 | EPA 4546409 → |
CVAMA3117XMA*+ furnace: 59SP6B080V17**16Cold climate designationAHRI reference: 217934081 | 19.00 | 8.50 | 21600 | 1.92 | EPA 4546410 → |
CVAMA3117XMA*+ furnace: 59SU5B040M17**12Cold climate designationAHRI reference: 217934082 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4546411 → |
CVAMA3117XMA*+ furnace: 59SU5B060M17**16Cold climate designationAHRI reference: 217934083 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4546412 → |
CVAMA3117XMA*+ furnace: 59TN6C080C17**14Cold climate designationAHRI reference: 217934086 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4546414 → |
CVAMA3117XMA*+ furnace: 59TN7A060C17**16Cold climate designationAHRI reference: 217934087 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4546415 → |
CVAMA3117XMA*+ furnace: 59TN7A080C17**16Cold climate designationAHRI reference: 217934088 | 19.00 | 8.50 | 21800 | 1.90 | EPA 4546416 → |
CVAMA3117XMA*+ furnace: 59TP7A060V17**16Cold climate designationAHRI reference: 217934094 | 19.00 | 8.50 | 21800 | 1.90 | EPA 4546419 → |
CVAMA3117XMA*+ furnace: 59TP7A080V17**16Cold climate designationAHRI reference: 217934095 | 19.00 | 8.50 | 21600 | 1.92 | EPA 4546420 → |
CVAMA3117XMA*+ furnace: OVMAAB042112Cold climate designationAHRI reference: 217934098 | 19.00 | 8.50 | 21800 | 1.90 | EPA 4546423 → |
CVAMA3217XMA*+ furnace: 58SP*B045V14**12Cold climate designationAHRI reference: 217934101 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4546424 → |
CVAMA3217XMA*+ furnace: 58CU*B040C17**12Cold climate designationAHRI reference: 217934099 | 19.00 | 8.50 | 21200 | 1.90 | EPA 4546425 → |
CVAMA3217XMA*+ furnace: 58SP*B070V14**12Cold climate designationAHRI reference: 217934102 | 19.00 | 8.50 | 21600 | 1.90 | EPA 4546426 → |
CVAMA3217XMA*+ furnace: 58SP*B070V17**16Cold climate designationAHRI reference: 217934103 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4546427 → |
CVAMA3217XMA*+ furnace: 58SP*B090V17**16Cold climate designationAHRI reference: 217934104 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4546428 → |
CVAMA3217XMA*+ furnace: 58SU*B040M17**12Cold climate designationAHRI reference: 217934105 | 19.00 | 8.50 | 21400 | 1.90 | EPA 4546429 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →