| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–23 | 430 / 430 |
| EER2 · BTU/Wh | 10.5–14 | 430 / 430 |
| HSPF2 · BTU/Wh | 8.5–10.5 | 430 / 430 |
| Cooling capacity · BTU/h | 21,600–23,800 | 430 / 430 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 24,800–28,200 | 430 / 430 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,000–26,400 | 430 / 430 |
| Heating capacity at 5°F / −15°C · BTU/h | 19,100–23,000 | 430 / 430 |
| COP at 5°F / −15°C | 1.84–2.1 | 430 / 430 |
| Equipment / loop type | HP - Split System | 430 / 430 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 430 / 430 |
| Compressor staging | Continuously variable | 430 / 430 |
| Connected capability | No | 430 / 430 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CVAVA3621XMA*+UI+ furnace: 59TN7A080C17**16Cold climate designationAHRI reference: 217625101 | 21.50 | 9.00 | 22400 | 1.98 | EPA 4499669 → |
CVAVA3721XMA*+UI+ furnace: 59TN7A080C17**16Cold climate designationAHRI reference: 217625103 | 21.50 | 9.50 | 22400 | 2.06 | EPA 4499672 → |
CVAVA4217XMA*+UI+ furnace: 59TN7A080C17**16Cold climate designationAHRI reference: 217625107 | 21.50 | 9.00 | 22400 | 1.98 | EPA 4499675 → |
CVAVA4221XMA*+UI+ furnace: 59TN7A080C17**16Cold climate designationAHRI reference: 217625109 | 21.50 | 9.00 | 22400 | 1.98 | EPA 4499677 → |
CVAMA3017XMA*+UI+ furnace: 59MN7C060C17**14Cold climate designationAHRI reference: 217624857 | 21.50 | 9.00 | 22400 | 1.96 | EPA 4499681 → |
CVAMA3617XMA*+UI+ furnace: 59MN7C060C17**14Cold climate designationAHRI reference: 217624863 | 21.50 | 9.00 | 22400 | 1.96 | EPA 4499687 → |
CVAMA4221XMA*+UI+ furnace: 59MN7C060C17**14Cold climate designationAHRI reference: 217624865 | 21.50 | 9.00 | 22400 | 1.98 | EPA 4499688 → |
CVAMA4321XMA*+UI+ furnace: 59MN7C060C17**14Cold climate designationAHRI reference: 217624867 | 21.50 | 9.50 | 22400 | 2.08 | EPA 4499690 → |
CVAVA3621XMA*+UI+ furnace: 59MN7C060C17**14Cold climate designationAHRI reference: 217624881 | 21.50 | 9.00 | 22400 | 1.98 | EPA 4499704 → |
CVAVA3721XMA*+UI+ furnace: 59MN7C060C17**14Cold climate designationAHRI reference: 217624883 | 21.50 | 9.50 | 22400 | 2.08 | EPA 4499705 → |
CVAVA4217XMA*+UI+ furnace: 59MN7C060C17**14Cold climate designationAHRI reference: 217624887 | 21.50 | 9.00 | 22400 | 1.98 | EPA 4499710 → |
CVAVA4221XMA*+UI+ furnace: 59MN7C060C17**14Cold climate designationAHRI reference: 217624889 | 21.50 | 9.00 | 22400 | 1.98 | EPA 4499712 → |
CVAMA3117XMA*+UI+ furnace: 58TN*B045C17**12Cold climate designationAHRI reference: 217624675 | 21.50 | 9.50 | 22600 | 2.06 | EPA 4499778 → |
CVAMA4221XMA*+UI+ furnace: 58TN*B045C17**12Cold climate designationAHRI reference: 217624681 | 21.50 | 9.00 | 22400 | 1.98 | EPA 4499784 → |
CVAMA4321XMA*+UI+ furnace: 58TN*B045C17**12Cold climate designationAHRI reference: 217624683 | 21.50 | 9.50 | 22600 | 2.08 | EPA 4499786 → |
CVAVA3117XMA*+UI+ furnace: 58TN*B045C17**12Cold climate designationAHRI reference: 217624693 | 21.50 | 9.50 | 22600 | 2.06 | EPA 4499795 → |
CVAVA3621XMA*+UI+ furnace: 58TN*B045C17**12Cold climate designationAHRI reference: 217624697 | 21.50 | 9.00 | 22400 | 1.98 | EPA 4499800 → |
CVAVA3721XMA*+UI+ furnace: 58TN*B045C17**12Cold climate designationAHRI reference: 217624699 | 21.50 | 9.50 | 22600 | 2.08 | EPA 4499802 → |
CVAVA4217XMA*+UI+ furnace: 58TN*B045C17**12Cold climate designationAHRI reference: 217624703 | 21.50 | 9.00 | 22600 | 1.96 | EPA 4499806 → |
CVAVA4221XMA*+UI+ furnace: 58TN*B045C17**12Cold climate designationAHRI reference: 217624705 | 21.50 | 9.00 | 22400 | 1.98 | EPA 4499808 → |