Heating performance & equipment details
Ranges include the 430 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–23 | 430 / 430 |
| EER2 · BTU/Wh | 10.5–14 | 430 / 430 |
| HSPF2 · BTU/Wh | 8.5–10.5 | 430 / 430 |
| Cooling capacity · BTU/h | 21,600–23,800 | 430 / 430 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 24,800–28,200 | 430 / 430 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,000–26,400 | 430 / 430 |
| Heating capacity at 5°F / −15°C · BTU/h | 19,100–23,000 | 430 / 430 |
| COP at 5°F / −15°C | 1.84–2.1 | 430 / 430 |
| Equipment / loop type | HP - Split System | 430 / 430 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 430 / 430 |
| Compressor staging | Continuously variable | 430 / 430 |
| Connected capability | No | 430 / 430 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CAA**2417AM*+UI+ furnace: 59MN7C060C17**14Cold climate designationAHRI reference: 217624295 | 20.00 | 9.50 | 20000 | 1.96 | EPA 4499300 → |
CAA**2417AM*+UI+ furnace: 59MN7C080C17**14Cold climate designationAHRI reference: 217624297 | 20.00 | 9.50 | 19800 | 1.96 | EPA 4499302 → |
CAA**2417AM*+UI+ furnace: 59TN6C060C17**14Cold climate designationAHRI reference: 217624301 | 20.00 | 9.50 | 20000 | 1.96 | EPA 4499308 → |
CAA**2417AM*+UI+ furnace: 59TN7A080C17**16Cold climate designationAHRI reference: 217624307 | 20.00 | 9.50 | 20000 | 1.96 | EPA 4499314 → |
CAA**2517AM*+UI+ furnace: 59TN7A060C17**16Cold climate designationAHRI reference: 217624329 | 20.00 | 10.00 | 19500 | 2.08 | EPA 4499341 → |
CAA**3017AM*+UI+ furnace: 58TN*B045C17**12Cold climate designationAHRI reference: 217624341 | 20.00 | 9.50 | 19800 | 1.98 | EPA 4499414 → |
CAA**3017AM*+UI+ furnace: 59MN7C060C17**14Cold climate designationAHRI reference: 217624351 | 20.00 | 9.50 | 19800 | 1.96 | EPA 4499422 → |
CAA**3017AM*+UI+ furnace: 59TN7A060C17**16Cold climate designationAHRI reference: 217624361 | 20.00 | 9.50 | 19800 | 1.98 | EPA 4499432 → |
CAA**3617AM*+UI+ furnace: 58TN*B045C17**12Cold climate designationAHRI reference: 217624369 | 20.00 | 9.50 | 19800 | 1.96 | EPA 4499441 → |
CAA**3617AM*+UI+ furnace: 59TN7A060C17**16Cold climate designationAHRI reference: 217624387 | 20.00 | 9.50 | 19800 | 1.96 | EPA 4499459 → |
CVAMA2417XMA*+UI+ furnace: 59TN7A060C17**16Cold climate designationAHRI reference: 217625035 | 20.00 | 9.00 | 22200 | 2.02 | EPA 4499489 → |
CVAVA2417XMA*+UI+ furnace: 59TN7A060C17**16Cold climate designationAHRI reference: 217625053 | 20.00 | 9.00 | 22200 | 2.02 | EPA 4499508 → |
CAA**3717AM*+UI+ furnace: 58TN*B045C17**12Cold climate designationAHRI reference: 217624395 | 20.00 | 9.50 | 19600 | 1.96 | EPA 4499523 → |
CAA**3717AM*+UI+ furnace: 59TN7A060C17**16Cold climate designationAHRI reference: 217624413 | 20.00 | 9.50 | 19600 | 1.96 | EPA 4499541 → |
CAA**3721AM*+UI+ furnace: 59TN7A060C17**16Cold climate designationAHRI reference: 217624437 | 20.00 | 10.00 | 19400 | 2.08 | EPA 4499565 → |
CAA**4221AM*+UI+ furnace: 59TN7A060C17**16Cold climate designationAHRI reference: 217624461 | 20.00 | 9.50 | 19700 | 1.96 | EPA 4499589 → |
CVAMA2517XMA*+UI+ furnace: 59TN6C040C14**10Cold climate designationAHRI reference: 217624931 | 20.00 | 9.00 | 22800 | 1.98 | EPA 4499978 → |
CVAMA3617XMA*+UI+ furnace: 59TN6C040C14**10Cold climate designationAHRI reference: 217624939 | 20.00 | 9.00 | 22800 | 1.98 | EPA 4499986 → |
CVAVA2517XMA*+UI+ furnace: 59TN6C040C14**10Cold climate designationAHRI reference: 217624947 | 20.00 | 9.00 | 22800 | 1.98 | EPA 4499994 → |
CSAH*3012AM*+UI+ furnace: 58TN*B070C14**12Cold climate designationAHRI reference: 217624519 | 19.50 | 9.50 | 19700 | 1.96 | EPA 4499180 → |