Infinity 23 VS Heat Pump · source records, page 16
430 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 27VNA324A*030*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 430 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–23 | 430 / 430 |
| EER2 · BTU/Wh | 10.5–14 | 430 / 430 |
| HSPF2 · BTU/Wh | 8.5–10.5 | 430 / 430 |
| Cooling capacity · BTU/h | 21,600–23,800 | 430 / 430 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 24,800–28,200 | 430 / 430 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,000–26,400 | 430 / 430 |
| Heating capacity at 5°F / −15°C · BTU/h | 19,100–23,000 | 430 / 430 |
| COP at 5°F / −15°C | 1.84–2.1 | 430 / 430 |
| Equipment / loop type | HP - Split System | 430 / 430 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 430 / 430 |
| Compressor staging | Continuously variable | 430 / 430 |
| Connected capability | No | 430 / 430 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CAA**3721AM*+UI+ furnace: 59TN7A080C17**16Cold climate designationAHRI reference: 217624439 | 20.50 | 10.00 | 19300 | 2.06 | EPA 4499566 → |
CAA**4221AM*+UI+ furnace: 58TN*B045C17**12Cold climate designationAHRI reference: 217624445 | 20.50 | 9.50 | 19700 | 1.96 | EPA 4499573 → |
CAA**4221AM*+UI+ furnace: 58TN*B070C17**16Cold climate designationAHRI reference: 217624447 | 20.50 | 9.50 | 19600 | 1.96 | EPA 4499575 → |
CAA**4221AM*+UI+ furnace: 59CU5B060C17**16Cold climate designationAHRI reference: 217624451 | 20.50 | 9.50 | 19600 | 1.98 | EPA 4499579 → |
CAA**4221AM*+UI+ furnace: 59MN7C060C17**14Cold climate designationAHRI reference: 217624453 | 20.50 | 9.50 | 19600 | 1.96 | EPA 4499581 → |
CAA**4221AM*+UI+ furnace: 59MN7C080C17**14Cold climate designationAHRI reference: 217624455 | 20.50 | 9.50 | 19600 | 1.98 | EPA 4499583 → |
CAA**4221AM*+UI+ furnace: 59TN6C060C17**14Cold climate designationAHRI reference: 217624457 | 20.50 | 9.50 | 19600 | 1.98 | EPA 4499585 → |
CAA**4221AM*+UI+ furnace: 59TN7A080C17**16Cold climate designationAHRI reference: 217624463 | 20.50 | 9.50 | 19600 | 1.98 | EPA 4499591 → |
CAA**4321AM*+UI+ furnace: 58TN*B045C17**12Cold climate designationAHRI reference: 217624467 | 20.50 | 10.00 | 19400 | 2.08 | EPA 4499595 → |
CAA**4321AM*+UI+ furnace: 59MN7C060C17**14Cold climate designationAHRI reference: 217624475 | 20.50 | 10.00 | 19300 | 2.06 | EPA 4499603 → |
CAA**4321AM*+UI+ furnace: 59TN7A060C17**16Cold climate designationAHRI reference: 217624481 | 20.50 | 10.00 | 19400 | 2.06 | EPA 4499607 → |
CVAMA2417XMA*+UI+ furnace: 59TN7A080C17**16Cold climate designationAHRI reference: 217625073 | 20.50 | 9.00 | 22200 | 2.02 | EPA 4499641 → |
CVAVA2417XMA*+UI+ furnace: 59TN7A080C17**16Cold climate designationAHRI reference: 217625091 | 20.50 | 9.00 | 22200 | 2.02 | EPA 4499659 → |
CVAVA2417XMA*+UI+ furnace: 59MN7C060C17**14Cold climate designationAHRI reference: 217624871 | 20.50 | 9.00 | 22200 | 2.02 | EPA 4499694 → |
CVAMA2417XMA*+UI+ furnace: 59MN7C080C17**14Cold climate designationAHRI reference: 217624891 | 20.50 | 9.00 | 22200 | 2.02 | EPA 4499714 → |
CVAMA2417XMA*+UI+ furnace: 58TN*B045C17**12Cold climate designationAHRI reference: 217624669 | 20.50 | 9.00 | 22200 | 2.02 | EPA 4499772 → |
CVAVA2417XMA*+UI+ furnace: 58TN*B045C17**12Cold climate designationAHRI reference: 217624687 | 20.50 | 9.00 | 22200 | 2.02 | EPA 4499790 → |
CVAMA2414XMA*+UI+ furnace: 58TN*B070C14**12Cold climate designationAHRI reference: 217624707 | 20.50 | 9.00 | 22000 | 2.04 | EPA 4499810 → |
CVAVA2414XMA*+UI+ furnace: 58TN*B070C14**12Cold climate designationAHRI reference: 217624721 | 20.50 | 9.00 | 22000 | 2.04 | EPA 4499824 → |
CVAMA2417XMA*+UI+ furnace: 58TN*B070C17**16Cold climate designationAHRI reference: 217624741 | 20.50 | 9.00 | 22200 | 2.02 | EPA 4499844 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.