Carrier / AIR-SOURCE HEAT PUMP

27VNA324A*030*

Infinity 23 VS Heat Pump · source records, page 16

430 published source records · source checked Sep 21, 2026

SEER2 range18–23BTU/Wh
HSPF2 range8.5–10.5BTU/Wh
Cooling capacity21,600–23,800BTU/h

Each efficiency range summarizes published EPA records for 27VNA324A*030*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 430 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh18–23430 / 430
EER2 · BTU/Wh10.5–14430 / 430
HSPF2 · BTU/Wh8.5–10.5430 / 430
Cooling capacity · BTU/h21,600–23,800430 / 430
Heating capacity at 47°F / 8.3°C · BTU/h24,800–28,200430 / 430
Heating capacity at 17°F / −8.3°C · BTU/h24,000–26,400430 / 430
Heating capacity at 5°F / −15°C · BTU/h19,100–23,000430 / 430
COP at 5°F / −15°C1.84–2.1430 / 430
Equipment / loop typeHP - Split System430 / 430
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)430 / 430
Compressor stagingContinuously variable430 / 430
Connected capabilityNo430 / 430

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**3721AM*+UI+ furnace: 59TN7A080C17**16Cold climate designationAHRI reference: 21762443920.5010.00193002.06EPA 4499566
CAA**4221AM*+UI+ furnace: 58TN*B045C17**12Cold climate designationAHRI reference: 21762444520.509.50197001.96EPA 4499573
CAA**4221AM*+UI+ furnace: 58TN*B070C17**16Cold climate designationAHRI reference: 21762444720.509.50196001.96EPA 4499575
CAA**4221AM*+UI+ furnace: 59CU5B060C17**16Cold climate designationAHRI reference: 21762445120.509.50196001.98EPA 4499579
CAA**4221AM*+UI+ furnace: 59MN7C060C17**14Cold climate designationAHRI reference: 21762445320.509.50196001.96EPA 4499581
CAA**4221AM*+UI+ furnace: 59MN7C080C17**14Cold climate designationAHRI reference: 21762445520.509.50196001.98EPA 4499583
CAA**4221AM*+UI+ furnace: 59TN6C060C17**14Cold climate designationAHRI reference: 21762445720.509.50196001.98EPA 4499585
CAA**4221AM*+UI+ furnace: 59TN7A080C17**16Cold climate designationAHRI reference: 21762446320.509.50196001.98EPA 4499591
CAA**4321AM*+UI+ furnace: 58TN*B045C17**12Cold climate designationAHRI reference: 21762446720.5010.00194002.08EPA 4499595
CAA**4321AM*+UI+ furnace: 59MN7C060C17**14Cold climate designationAHRI reference: 21762447520.5010.00193002.06EPA 4499603
CAA**4321AM*+UI+ furnace: 59TN7A060C17**16Cold climate designationAHRI reference: 21762448120.5010.00194002.06EPA 4499607
CVAMA2417XMA*+UI+ furnace: 59TN7A080C17**16Cold climate designationAHRI reference: 21762507320.509.00222002.02EPA 4499641
CVAVA2417XMA*+UI+ furnace: 59TN7A080C17**16Cold climate designationAHRI reference: 21762509120.509.00222002.02EPA 4499659
CVAVA2417XMA*+UI+ furnace: 59MN7C060C17**14Cold climate designationAHRI reference: 21762487120.509.00222002.02EPA 4499694
CVAMA2417XMA*+UI+ furnace: 59MN7C080C17**14Cold climate designationAHRI reference: 21762489120.509.00222002.02EPA 4499714
CVAMA2417XMA*+UI+ furnace: 58TN*B045C17**12Cold climate designationAHRI reference: 21762466920.509.00222002.02EPA 4499772
CVAVA2417XMA*+UI+ furnace: 58TN*B045C17**12Cold climate designationAHRI reference: 21762468720.509.00222002.02EPA 4499790
CVAMA2414XMA*+UI+ furnace: 58TN*B070C14**12Cold climate designationAHRI reference: 21762470720.509.00220002.04EPA 4499810
CVAVA2414XMA*+UI+ furnace: 58TN*B070C14**12Cold climate designationAHRI reference: 21762472120.509.00220002.04EPA 4499824
CVAMA2417XMA*+UI+ furnace: 58TN*B070C17**16Cold climate designationAHRI reference: 21762474120.509.00222002.02EPA 4499844

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.