27VNA324A*030*
Infinity 23 VS Heat Pump · source records, page 14
430 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 27VNA324A*030*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 430 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–23 | 430 / 430 |
| EER2 · BTU/Wh | 10.5–14 | 430 / 430 |
| HSPF2 · BTU/Wh | 8.5–10.5 | 430 / 430 |
| Cooling capacity · BTU/h | 21,600–23,800 | 430 / 430 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 24,800–28,200 | 430 / 430 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,000–26,400 | 430 / 430 |
| Heating capacity at 5°F / −15°C · BTU/h | 19,100–23,000 | 430 / 430 |
| COP at 5°F / −15°C | 1.84–2.1 | 430 / 430 |
| Equipment / loop type | HP - Split System | 430 / 430 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 430 / 430 |
| Compressor staging | Continuously variable | 430 / 430 |
| Connected capability | No | 430 / 430 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CVAVA2417XMA*+UI+ furnace: 59MN7C080C17**14Cold climate designationAHRI reference: 217624907 | 21.00 | 9.00 | 22200 | 2.02 | EPA 4499954 → |
CVAMA3217XMA*+UI+ furnace: 59TN6C040C14**10Cold climate designationAHRI reference: 217624937 | 21.00 | 9.00 | 23000 | 1.94 | EPA 4499983 → |
CAA**2414AM*+UI+ furnace: 58TN*B070C14**12Cold climate designationAHRI reference: 217624277 | 20.50 | 10.50 | 20000 | 2.00 | EPA 4499220 → |
CAA**2417AM*+UI+ furnace: 58CU*B040C17**12Cold climate designationAHRI reference: 217624281 | 20.50 | 9.50 | 19800 | 1.98 | EPA 4499223 → |
CAA**2417AM*+UI+ furnace: 58CU*B060C17**16Cold climate designationAHRI reference: 217624283 | 20.50 | 9.50 | 19800 | 1.96 | EPA 4499225 → |
CAA**2417AM*+UI+ furnace: 58TN*B070C14**12Cold climate designationAHRI reference: 217624287 | 20.50 | 9.50 | 20000 | 1.98 | EPA 4499229 → |
CAA**2417AM*+UI+ furnace: 58TN*B090C17**16Cold climate designationAHRI reference: 217624291 | 20.50 | 9.50 | 20000 | 1.98 | EPA 4499296 → |
CAA**2417AM*+UI+ furnace: 59TN6C080C17**14Cold climate designationAHRI reference: 217624303 | 20.50 | 9.50 | 20000 | 1.98 | EPA 4499310 → |
CAA**2517AM*+UI+ furnace: 58TN*B045C17**12Cold climate designationAHRI reference: 217624313 | 20.50 | 10.00 | 19500 | 2.06 | EPA 4499320 → |
CAA**2517AM*+UI+ furnace: 59CU5B060C17**16Cold climate designationAHRI reference: 217624319 | 20.50 | 10.00 | 19400 | 2.06 | EPA 4499326 → |
CVAVA4217XMA*+UI+ furnace: 59TN6C040C14**10Cold climate designationAHRI reference: 217624959 | 20.50 | 9.00 | 22800 | 1.96 | EPA 4499330 → |
CVAMA2417XMA*+UI+ furnace: 59TN6C060C17**14Cold climate designationAHRI reference: 217624961 | 20.50 | 9.00 | 22200 | 2.02 | EPA 4499334 → |
CAA**2517AM*+UI+ furnace: 59TN6C060C17**14Cold climate designationAHRI reference: 217624325 | 20.50 | 10.00 | 19400 | 2.06 | EPA 4499336 → |
CAA**2517AM*+UI+ furnace: 59TN7A080C17**16Cold climate designationAHRI reference: 217624331 | 20.50 | 10.00 | 19400 | 2.06 | EPA 4499344 → |
CVAMA2417XMA*+UI+ furnace: 59MN7C060C17**14Cold climate designationAHRI reference: 217624853 | 20.50 | 9.00 | 22200 | 2.02 | EPA 4499365 → |
CAA**3014AM*+UI+ furnace: 58TN*B070C14**12Cold climate designationAHRI reference: 217624333 | 20.50 | 9.50 | 19800 | 1.96 | EPA 4499406 → |
CAA**3017AM*+UI+ furnace: 58TN*B070C14**12Cold climate designationAHRI reference: 217624343 | 20.50 | 9.50 | 19700 | 1.96 | EPA 4499415 → |
CAA**3017AM*+UI+ furnace: 58TN*B070C17**16Cold climate designationAHRI reference: 217624345 | 20.50 | 9.50 | 19700 | 1.96 | EPA 4499417 → |
CAA**3017AM*+UI+ furnace: 58TN*B090C17**16Cold climate designationAHRI reference: 217624347 | 20.50 | 9.50 | 19700 | 1.98 | EPA 4499419 → |
CAA**3017AM*+UI+ furnace: 59CU5B060C17**16Cold climate designationAHRI reference: 217624349 | 20.50 | 9.50 | 19800 | 1.96 | EPA 4499421 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →