27VNA324A*030*
Infinity 23 VS Heat Pump · source records, page 11
430 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 27VNA324A*030*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 430 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–23 | 430 / 430 |
| EER2 · BTU/Wh | 10.5–14 | 430 / 430 |
| HSPF2 · BTU/Wh | 8.5–10.5 | 430 / 430 |
| Cooling capacity · BTU/h | 21,600–23,800 | 430 / 430 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 24,800–28,200 | 430 / 430 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,000–26,400 | 430 / 430 |
| Heating capacity at 5°F / −15°C · BTU/h | 19,100–23,000 | 430 / 430 |
| COP at 5°F / −15°C | 1.84–2.1 | 430 / 430 |
| Equipment / loop type | HP - Split System | 430 / 430 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 430 / 430 |
| Compressor staging | Continuously variable | 430 / 430 |
| Connected capability | No | 430 / 430 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CAA**2517AM*+UI+ furnace: 58TN*B070C14**12Cold climate designationAHRI reference: 217624315 | 21.00 | 10.00 | 19300 | 2.06 | EPA 4499322 → |
CAA**2517AM*+UI+ furnace: 58TN*B090C17**16Cold climate designationAHRI reference: 217624317 | 21.00 | 10.00 | 19300 | 2.08 | EPA 4499324 → |
CAA**2517AM*+UI+ furnace: 59MN7C080C17**14Cold climate designationAHRI reference: 217624321 | 21.00 | 10.00 | 19400 | 2.06 | EPA 4499328 → |
CAA**2517AM*+UI+ furnace: 59TN6C080C17**14Cold climate designationAHRI reference: 217624327 | 21.00 | 10.00 | 19300 | 2.06 | EPA 4499339 → |
CVAVA2417XMA*+UI+ furnace: 59TN6C060C17**14Cold climate designationAHRI reference: 217624979 | 21.00 | 9.00 | 22200 | 2.02 | EPA 4499379 → |
CVAMA2417XMA*+UI+ furnace: 59TN6C080C17**14Cold climate designationAHRI reference: 217624999 | 21.00 | 9.00 | 22200 | 2.02 | EPA 4499400 → |
CAA**3017AM*+UI+ furnace: 58CU*B040C17**12Cold climate designationAHRI reference: 217624337 | 21.00 | 9.50 | 19600 | 1.96 | EPA 4499409 → |
CAA**3017AM*+UI+ furnace: 58CU*B060C17**16Cold climate designationAHRI reference: 217624339 | 21.00 | 9.50 | 19700 | 1.96 | EPA 4499411 → |
CAA**3617AM*+UI+ furnace: 58CU*B040C17**12Cold climate designationAHRI reference: 217624365 | 21.00 | 9.50 | 19600 | 1.98 | EPA 4499437 → |
CAA**3617AM*+UI+ furnace: 58CU*B060C17**16Cold climate designationAHRI reference: 217624367 | 21.00 | 9.50 | 19600 | 1.98 | EPA 4499439 → |
CAA**3617AM*+UI+ furnace: 58TN*B070C14**12Cold climate designationAHRI reference: 217624371 | 21.00 | 9.50 | 19700 | 1.96 | EPA 4499443 → |
CAA**3617AM*+UI+ furnace: 58TN*B090C17**16Cold climate designationAHRI reference: 217624375 | 21.00 | 9.50 | 19600 | 1.96 | EPA 4499447 → |
CVAVA2417XMA*+UI+ furnace: 59TN6C080C17**14Cold climate designationAHRI reference: 217625015 | 21.00 | 9.00 | 22000 | 2.02 | EPA 4499471 → |
CVAMA2517XMA*+UI+ furnace: 59TN7A060C17**16Cold climate designationAHRI reference: 217625037 | 21.00 | 9.00 | 22400 | 1.98 | EPA 4499493 → |
CVAMA3017XMA*+UI+ furnace: 59TN7A060C17**16Cold climate designationAHRI reference: 217625039 | 21.00 | 9.00 | 22400 | 1.98 | EPA 4499494 → |
CVAMA4221XMA*+UI+ furnace: 59TN7A060C17**16Cold climate designationAHRI reference: 217625047 | 21.00 | 9.00 | 22400 | 1.98 | EPA 4499502 → |
CVAVA2517XMA*+UI+ furnace: 59TN7A060C17**16Cold climate designationAHRI reference: 217625055 | 21.00 | 9.00 | 22400 | 1.98 | EPA 4499510 → |
CVAVA3017XMA*+UI+ furnace: 59TN7A060C17**16Cold climate designationAHRI reference: 217625057 | 21.00 | 9.00 | 22400 | 1.98 | EPA 4499512 → |
CVAMA3617XMA*+UI+ furnace: 59TN7A060C17**16Cold climate designationAHRI reference: 217625045 | 21.00 | 9.00 | 22400 | 1.98 | EPA 4499513 → |
CAA**3717AM*+UI+ furnace: 58CU*B040C17**12Cold climate designationAHRI reference: 217624391 | 21.00 | 10.00 | 19400 | 2.08 | EPA 4499519 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →