Carrier / AIR-SOURCE HEAT PUMP

27VNA324A*030*

Infinity 23 VS Heat Pump · source records, page 11

430 published source records · source checked Sep 21, 2026

SEER2 range18–23BTU/Wh
HSPF2 range8.5–10.5BTU/Wh
Cooling capacity21,600–23,800BTU/h

Each efficiency range summarizes published EPA records for 27VNA324A*030*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 430 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh18–23430 / 430
EER2 · BTU/Wh10.5–14430 / 430
HSPF2 · BTU/Wh8.5–10.5430 / 430
Cooling capacity · BTU/h21,600–23,800430 / 430
Heating capacity at 47°F / 8.3°C · BTU/h24,800–28,200430 / 430
Heating capacity at 17°F / −8.3°C · BTU/h24,000–26,400430 / 430
Heating capacity at 5°F / −15°C · BTU/h19,100–23,000430 / 430
COP at 5°F / −15°C1.84–2.1430 / 430
Equipment / loop typeHP - Split System430 / 430
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)430 / 430
Compressor stagingContinuously variable430 / 430
Connected capabilityNo430 / 430

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**2517AM*+UI+ furnace: 58TN*B070C14**12Cold climate designationAHRI reference: 21762431521.0010.00193002.06EPA 4499322
CAA**2517AM*+UI+ furnace: 58TN*B090C17**16Cold climate designationAHRI reference: 21762431721.0010.00193002.08EPA 4499324
CAA**2517AM*+UI+ furnace: 59MN7C080C17**14Cold climate designationAHRI reference: 21762432121.0010.00194002.06EPA 4499328
CAA**2517AM*+UI+ furnace: 59TN6C080C17**14Cold climate designationAHRI reference: 21762432721.0010.00193002.06EPA 4499339
CVAVA2417XMA*+UI+ furnace: 59TN6C060C17**14Cold climate designationAHRI reference: 21762497921.009.00222002.02EPA 4499379
CVAMA2417XMA*+UI+ furnace: 59TN6C080C17**14Cold climate designationAHRI reference: 21762499921.009.00222002.02EPA 4499400
CAA**3017AM*+UI+ furnace: 58CU*B040C17**12Cold climate designationAHRI reference: 21762433721.009.50196001.96EPA 4499409
CAA**3017AM*+UI+ furnace: 58CU*B060C17**16Cold climate designationAHRI reference: 21762433921.009.50197001.96EPA 4499411
CAA**3617AM*+UI+ furnace: 58CU*B040C17**12Cold climate designationAHRI reference: 21762436521.009.50196001.98EPA 4499437
CAA**3617AM*+UI+ furnace: 58CU*B060C17**16Cold climate designationAHRI reference: 21762436721.009.50196001.98EPA 4499439
CAA**3617AM*+UI+ furnace: 58TN*B070C14**12Cold climate designationAHRI reference: 21762437121.009.50197001.96EPA 4499443
CAA**3617AM*+UI+ furnace: 58TN*B090C17**16Cold climate designationAHRI reference: 21762437521.009.50196001.96EPA 4499447
CVAVA2417XMA*+UI+ furnace: 59TN6C080C17**14Cold climate designationAHRI reference: 21762501521.009.00220002.02EPA 4499471
CVAMA2517XMA*+UI+ furnace: 59TN7A060C17**16Cold climate designationAHRI reference: 21762503721.009.00224001.98EPA 4499493
CVAMA3017XMA*+UI+ furnace: 59TN7A060C17**16Cold climate designationAHRI reference: 21762503921.009.00224001.98EPA 4499494
CVAMA4221XMA*+UI+ furnace: 59TN7A060C17**16Cold climate designationAHRI reference: 21762504721.009.00224001.98EPA 4499502
CVAVA2517XMA*+UI+ furnace: 59TN7A060C17**16Cold climate designationAHRI reference: 21762505521.009.00224001.98EPA 4499510
CVAVA3017XMA*+UI+ furnace: 59TN7A060C17**16Cold climate designationAHRI reference: 21762505721.009.00224001.98EPA 4499512
CVAMA3617XMA*+UI+ furnace: 59TN7A060C17**16Cold climate designationAHRI reference: 21762504521.009.00224001.98EPA 4499513
CAA**3717AM*+UI+ furnace: 58CU*B040C17**12Cold climate designationAHRI reference: 21762439121.0010.00194002.08EPA 4499519

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →