Carrier / AIR-SOURCE HEAT PUMP

27VNA154A*030*

Infinity 21 VS Cold Climate Heat Pump · source records, page 8

155 published source records · source checked Sep 21, 2026

SEER2 range17–21BTU/Wh
HSPF2 range8–10.5BTU/Wh
Cooling capacity47,500–53,500BTU/h

Each efficiency range summarizes published EPA records for 27VNA154A*030*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 155 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh17–21155 / 155
EER2 · BTU/Wh10–13155 / 155
HSPF2 · BTU/Wh8–10.5155 / 155
Cooling capacity · BTU/h47,500–53,500155 / 155
Heating capacity at 47°F / 8.3°C · BTU/h51,000–54,500155 / 155
Heating capacity at 17°F / −8.3°C · BTU/h47,500–52,000155 / 155
Heating capacity at 5°F / −15°C · BTU/h45,500–54,000155 / 155
COP at 5°F / −15°C1.78–2155 / 155
Equipment / loop typeHP - Split System155 / 155
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)155 / 155
Compressor stagingContinuously variable155 / 155
Connected capabilityNo155 / 155

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CSAH*6012AM*+UI+ furnace: 59MN7C080C21**20Cold climate designationAHRI reference: 21558817918.509.50525001.94EPA 3719992
CSAH*6012AM*+UI+ furnace: 58TN*B135C24**22Cold climate designationAHRI reference: 21558816718.509.50530001.90EPA 3720005
CVAMA6124XMA*+UI+ furnace: 59MN7C060C21**20AHRI reference: 21558827918.508.00465001.82EPA 3720008
CVAVA4824XMA*+UI+ furnace: 59CU5B080C21**20AHRI reference: 21558830318.508.00455001.86EPA 4705580
CAA**6024AM*+UI+ furnace: 59MN7C060C21**20Cold climate designationAHRI reference: 21558810118.009.50535001.96EPA 3719811
CSAH*4812AM*+UI+ furnace: 59MN7C080C21**20Cold climate designationAHRI reference: 21558814718.009.50520001.90EPA 3719817
CSAH*6012AM*+UI+ furnace: 58TN*B070C21**20Cold climate designationAHRI reference: 21558816118.009.50540001.88EPA 3719819
CSAH*6012AM*+UI+ furnace: 59CU5B080C21**20Cold climate designationAHRI reference: 21558817118.009.50525001.94EPA 3719925
CVAMA4821XMA*+UI+ furnace: 59MN7C080C21**20AHRI reference: 21558820318.008.00455001.88EPA 3719957
CVAVA4821XMA*+UI+ furnace: 59MN7C080C21**20AHRI reference: 21558830118.008.00455001.88EPA 3719986
CVAVA4821XMA*+UI+ furnace: 59CU5B080C21**20AHRI reference: 21558829718.008.00455001.88EPA 4705582
CVAMA4821XMA*+UI+ furnace: 59CU5B080C21**20AHRI reference: 21558819918.008.00455001.88EPA 4705590
CSAH*4812AM*+UI+ furnace: 59CU5B080C21**20Cold climate designationAHRI reference: 21558814117.509.50520001.90EPA 3719795
CSAH*6012AM*+UI+ furnace: 59MN7C060C21**20Cold climate designationAHRI reference: 21558817517.509.00530001.82EPA 3719936
CSAH*4812AM*+UI+ furnace: 59MN7C060C21**20Cold climate designationAHRI reference: 21558814317.009.50530001.90EPA 3719949