Carrier / AIR-SOURCE HEAT PUMP

27VNA154A*030*

Infinity 21 VS Cold Climate Heat Pump · source records, page 4

155 published source records · source checked Sep 21, 2026

SEER2 range17–21BTU/Wh
HSPF2 range8–10.5BTU/Wh
Cooling capacity47,500–53,500BTU/h

Each efficiency range summarizes published EPA records for 27VNA154A*030*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 155 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh17–21155 / 155
EER2 · BTU/Wh10–13155 / 155
HSPF2 · BTU/Wh8–10.5155 / 155
Cooling capacity · BTU/h47,500–53,500155 / 155
Heating capacity at 47°F / 8.3°C · BTU/h51,000–54,500155 / 155
Heating capacity at 17°F / −8.3°C · BTU/h47,500–52,000155 / 155
Heating capacity at 5°F / −15°C · BTU/h45,500–54,000155 / 155
COP at 5°F / −15°C1.78–2155 / 155
Equipment / loop typeHP - Split System155 / 155
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)155 / 155
Compressor stagingContinuously variable155 / 155
Connected capabilityNo155 / 155

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAA**6024AM*+UI+ furnace: 58CU*B100C21**20Cold climate designationAHRI reference: 21558842719.009.50530001.90EPA 3719800 →
CVAVA4924XMA*+UI+ furnace: 59TN7A080C21**20AHRI reference: 21558851919.008.00465001.80EPA 3719802 →
CVAVA4924XMA*+UI+ furnace: 59TN6C080C21**20AHRI reference: 21558851319.008.00465001.80EPA 3719803 →
CVAVA4924XMA*+UI+ furnace: 59TN7A120C24**22Cold climate designationAHRI reference: 21558852319.008.50465001.92EPA 3719804 →
CAA**6024AM*+UI+ furnace: 59TN6C080C21**20Cold climate designationAHRI reference: 21558842319.009.50535001.90EPA 3719805 →
CSAH*6012AM*+UI+ furnace: 58CU*B080C21**20Cold climate designationAHRI reference: 21558845319.009.50525001.90EPA 3719806 →
CAA**6024AM*+UI+ furnace: 58CU*A100C21**20Cold climate designationAHRI reference: 21558808919.0010.50535001.96EPA 3719809 →
CVAVA4924XMA*+UI+ furnace: 58TN*B070C21**20AHRI reference: 21558831319.008.00470001.78EPA 3719813 →
CVAVA6024XMA*+UI+ furnace: 59TN6C120C24**22Cold climate designationAHRI reference: 21558837319.008.50465001.92EPA 3719815 →
CVAVA6024XMA*+UI+ furnace: 59MN7C100C21**22Cold climate designationAHRI reference: 21558836719.008.50465001.90EPA 3719823 →
CVAVA6121XMA*+UI+ furnace: 59MN7C080C21**20Cold climate designationAHRI reference: 21558838719.008.50455001.94EPA 3719824 →
CAA**6024AM*+UI+ furnace: 59MN7C100C21**22Cold climate designationAHRI reference: 21558810519.009.50535001.92EPA 3719825 →
CVAMA6024XMA*+UI+ furnace: 59MN7C100C21**22Cold climate designationAHRI reference: 21558825919.008.50465001.90EPA 3719826 →
CVAVA4924XMA*+UI+ furnace: 59TN6C120C24**22Cold climate designationAHRI reference: 21558833319.008.50465001.92EPA 3719828 →
CVAVA6024XMA*+UI+ furnace: 59TN7A080C21**20AHRI reference: 21558853719.008.00465001.80EPA 3719840 →
CAA**6124AM*+UI+ furnace: 59MN7C080C21**20Cold climate designationAHRI reference: 21558813119.009.50525001.90EPA 3719842 →
CVAMA6024XMA*+UI+ furnace: 58TN*B070C21**20AHRI reference: 21558824319.008.00470001.80EPA 3719845 →
CAA**6024AM*+UI+ furnace: 59TN7A100C21**22Cold climate designationAHRI reference: 21558843119.009.50535001.92EPA 3719856 →
CAA**6121AM*+UI+ furnace: 59MN7C080C21**20Cold climate designationAHRI reference: 21558812319.009.50530001.92EPA 3719899 →
CVAVA4924XMA*+UI+ furnace: 59MN7C100C21**22Cold climate designationAHRI reference: 21558832719.008.50465001.90EPA 3719901 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →